Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Aerosol Sci ; 178: 1-20, 2024 May.
Article in English | MEDLINE | ID: mdl-38751612

ABSTRACT

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nonvolatile particulate matter (nvPM) emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program was devised to understand reported variability in the ARP6320A sampling system nvPM measurements. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 campaigns devoted to: (1) assessing the response of three different black carbon mass analyzers to particles of different size, morphology, and chemical composition; (2) characterizing the particles generated by 6 different combustion sources according to morphology, effective density, and chemical composition; and (3) assessing any significant difference between black carbon as determined by the 3 mass analyzers and the total PM determined via other techniques. Results from VARIAnT 3 and 4 campaigns revealed agreement of about 20% between the Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC) mass, independent of the calibration source used. For the LII-300, the measured mass concentrations in VARIAnT 3 fall within 18% and in VARIAnT 4 fall within 27% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT 3 and on an LGT-60 start cart in VARIAnT 4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion as a particle source (combustor or turbine engine). With respect to the particle size measurements, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Gravimetric measurements of the total aerosol mass produced by the various DFCAs differed from the reference EC, BC and integrated particle size distribution measured aerosol masses. The measurements of particle size distributions and single particle analysis performed using the miniSPLAT indicated the presence of larger particles (≳150 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and containing ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E-31 assumption that engine exit exhaust particles are mainly composed of black carbon.

2.
J Aerosol Sci ; 159: 1-31, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35530659

ABSTRACT

There is no universally agreed upon definition for ultrafine particles (UFP). Commonly used definitions for UFP are either particle number below 100 nm or total particle number, but without an agreed upon lower cut point. For example, a lower cut point of 3 nm compared to 10 nm could result in a substantially higher count. Another definition for UFP is total particle mass but without a commonly agreed upon aerodynamic diameter upper cut point, e.g., below 100 nm, 200 nm, 300 nm, etc. Yet another definition is lung deposited surface area weighted by lung deposition fraction, found mainly in the particle mobility diameter range from 20 to 400 nm. It is clear from these definitions that there are inconsistencies in the way UFP is used and defined in the literature. Sometimes these metrics are well correlated, sometimes not. In this paper we suggest three exposure metrics: UFP-N, UFP-M, and UFP-S, that we believe will add clarity. These metrics represent total number, mass, and surface area below 500 nm, respectively. For surface area and mass, the 500 nm cut point can be either aerodynamic or mobility diameter depending upon measurement methodology. For all metrics, this cut point captures nearly all of the primary particle emissions from mobile sources. Furthermore, UFP-N would include a lower cut point of 3-6 nm and would not require an upper size cut point because there is very little particle number above 500 nm or even above 100 nm. Thus, our definition of UFP-N is consistent with the current definition of ultrafine number except for, importantly, the specification of a lower cut point. These exposure metrics can help facilitate consistency in the characterization of both short- and long-term UFP ambient exposures and associated health effects in epidemiological studies.

3.
J Aerosol Sci ; 154: 1-16, 2021 May.
Article in English | MEDLINE | ID: mdl-35949248

ABSTRACT

The SAE International has published Aerospace Information Report (AIR) 6241 which outlined the design and operation of a standardized measurement system for measuring non-volatile particulate matter (nvPM) mass and number emissions from commercial aircraft engines. Prior to this research, evaluation of this system by various investigators revealed differences in nvPM mass emissions measurement on the order of 15-30% both within a single sampling system and between two systems operating in parallel and measuring nvPM mass emissions from the same source. To investigate this issue, the U. S. Environmental Protection Agency in collaboration with the U. S. Air Force's Arnold Engineering Development Complex initiated the VAriable Response In Aircraft nvPM Testing (VARIAnT) research program to compare nvPM measurements within and between AIR-compliant sampling systems used for measuring combustion aerosols generated both by a 5201 Mini-CAST soot generator and a J85-GE-5 turbojet engine burning multiple fuels. The VARIAnT research program has conducted four test campaigns to date. The first campaign (VARIAnT 1) compared two essentially identical commercial versions of the sampling system while the second campaign (VARIAnT 2) compared a commercial system to the custom-designed Missouri University of Science and Technology's North American Reference System (NARS) built to the same specifications. Comparisons of nvPM particle mass (i.e., black carbon), number, and size were conducted in both campaigns. Additionally, the sensitivity to variation in system operational parameters was evaluated in VARIAnT 1. Results from both campaigns revealed agreement of about 12% between the two sampling systems, irrespective of manufacturer, in all aspects except for black carbon determination. The major source of measurement differences (20-70%) was due to low BC mass measurements made by the Artium Technologies LII-300 as compared to the AVL 483 Micro-Soot Sensor, the Aerodyne Cavity Attenuated Phase Shift (CAPS PMSSA) monitor, and the thermal-optical reference method for elemental carbon (EC) determination, which was used as the BC reference.

5.
Environ Sci Technol ; 45(14): 6073-9, 2011 Jul 15.
Article in English | MEDLINE | ID: mdl-21662983

ABSTRACT

Heavy duty emissions regulations have recently expanded from the laboratory to include in-use requirements. This paradigm shift to in-use testing has forced the development of portable emissions measurement systems (PEMS) for particulate matter (PM). These PM measurements are not trivial for laboratory work, and are even more complex for in-use testing. This study evaluates five PM PEMS in comparison to UCR's mobile reference laboratory under in-use conditions. Three on-highway, heavy-duty trucks were selected to provide PM emissions levels from 0.1 to 0.0003 g/hp-h, with varying compositions of elemental carbon (EC), organic carbon (OC), and sulfate. The on-road driving courses included segments near sea level, at elevations up to 1500 m, and coastal and desert regions. The photoacoustic measurement PEMS performed best for the non-after treatment system (ATS)-equipped engine, where the PM was mostly EC, with a linear regression slope of 0.91 and an R(2) of 0.95. The PEMS did not perform as well for the 2007 modified ATS equipped engines. The best performing PEMS showed a slope of 0.16 for the ATS-equipped engine with predominantly sulfate emissions and 0.89 for the ATS-equipped engine with predominantly OC emissions, with the next best slope at 0.45 for the predominantly OC engine.


Subject(s)
Environmental Monitoring/instrumentation , Gasoline , Motor Vehicles , Particulate Matter/analysis , Vehicle Emissions/analysis , Carbon/analysis , Chromatography, Ion Exchange , Environmental Monitoring/methods , Geography , Linear Models , Particle Size , Sulfates/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...