Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Ann Vasc Surg ; 62: 191-194, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31449950

ABSTRACT

BACKGROUND: Percutaneous endovascular aortic repairs (pEVARs) are associated with access site complications. Two-device technique using 2 Perclose devices has been well established. Combined Perclose and Angioseal technique has been described as well. We sought to determine whether a hybrid Perclose and Angioseal closure technique would safely and effectively establish hemostasis in large-bore arteriotomies up to 20F. METHODS: Patients were identified as candidates for percutaneous access based on preoperative computed tomography findings, perioperative ultrasound of femoral vessels, or a combination of the 2 modalities. Prior to sheath insertion, 1 Perclose device was predeployed. At the end of pEVAR, device sheath and introducer were withdrawn over a 0.035″ wire, and partially deployed Perclose was fully deployed. The sheath and introducer were fully withdrawn and the arteriotomy was closed with a 6F Angioseal vascular closure device and completion deployment of the Perclose. Patients were followed at day 1 and day 30 and at least 1 year postintervention. RESULTS: A composite end point of complications was defined as an access site-related bleed or hematoma that required blood transfusion or an extended hospital stay, pseudoaneurysm, arteriovenous fistula, dissection, or retroperitoneal hematoma. The combined technique was initially successful in 44/45 arteriotomies (97.8%) in 24/25 patients (96.0%) with no conversions to cutdown. Sheath sizes ranged from 10F to 20F outer diameter (OD), with an average of 15.89F OD. The single-device failure was caused by a failure of the footplate to catch during deployment in the Angioseal with a 20F arteriotomy. Consequently, that was the only patient in which this closure was attempted for an arteriotomy larger than 19F. There were no early or late complications in this series. CONCLUSIONS: Large-bore arteriotomies may be safely and effectively closed using a hybrid percutaneous closure technique for sheaths up to 19F OD. Evaluation of this technique in closure of large-bore arteriotomies is ongoing and further investigation is needed to assess the value of this closure in 20F OD sheaths and above.


Subject(s)
Aortic Diseases/surgery , Catheterization, Peripheral , Endovascular Procedures , Hemorrhage/prevention & control , Hemostatic Techniques/instrumentation , Vascular Closure Devices , Aortic Diseases/diagnostic imaging , Blood Transfusion , Catheterization, Peripheral/adverse effects , Endovascular Procedures/adverse effects , Equipment Design , Hematoma/etiology , Hematoma/prevention & control , Hemorrhage/etiology , Hemostatic Techniques/adverse effects , Humans , Length of Stay , Punctures , Risk Factors , Time Factors , Treatment Outcome , Vascular System Injuries/etiology , Vascular System Injuries/prevention & control
2.
Ann Vasc Surg ; 46: 369.e7-369.e11, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28890056

ABSTRACT

BACKGROUND: We present an interesting case of a 55-year-old male with a large left chest mass after significant cutaneous bleeding. Computed tomography angiogram of the chest revealed arteriovenous malformation with blood supply from sub-branches of the left subclavian artery, left internal mammary artery, and left external carotid artery. Measuring 5.0 × 14.0 × 10.8 cm, the mass extended superior to the clavicle and inferior to the third rib with medial and lateral borders at the level of the clavicular head and coracoid, respectively. METHODS: Arteriovenous malformations (AVMs) are characterized by abnormal connections between arteries and veins which bypass the capillary system. Often small and asymptomatic, large AVMs can be painful, prone to bleeding and, if large enough, interfere with activities of daily living. While described involving various parts of the body, most notably in the central nervous system, there is a paucity of literature involving chest wall AVMs. RESULTS: Using a staged, multidisciplinary approach, treatment began with an endovascular exclusion of the arterial blood supply, which involved a combination of coil embolization and stent exclusion of feeder vessels. Two days postembolization, the patient underwent an en bloc resection of affected portion of his chest wall. Reconstruction was completed with a combination rotational flap and split-thickness skin graft. Following the procedures, the patient had an uncomplicated recovery. Three years following procedure, he has no signs of recurrence of his AV malformation. CONCLUSION: Surgical planning and indications for giant arteriovenous malformations remains a unique and difficult problem. The complex anatomy and extreme rarity of a chest wall AVM requires a multidisciplinary staged approach but can be treated with a multistage, multidisciplinary surgical approach with satisfactory and long-lasting results.


Subject(s)
Arteriovenous Malformations/surgery , Carotid Artery, External/surgery , Embolization, Therapeutic , Mammary Arteries/surgery , Skin Transplantation , Subclavian Artery/surgery , Thoracic Wall/blood supply , Vascular Surgical Procedures , Angiography, Digital Subtraction , Arteriovenous Malformations/diagnostic imaging , Carotid Artery, External/abnormalities , Carotid Artery, External/diagnostic imaging , Computed Tomography Angiography , Humans , Male , Mammary Arteries/abnormalities , Mammary Arteries/diagnostic imaging , Middle Aged , Subclavian Artery/abnormalities , Subclavian Artery/diagnostic imaging , Treatment Outcome
4.
Vascular ; 22(2): 85-92, 2014 Apr.
Article in English | MEDLINE | ID: mdl-23518836

ABSTRACT

Vertebral arterial disease (VAD) is a less commonly recognized and treated source of cerebrovascular ischemia compared with carotid artery disease. Patients are often referred for treatment after they have developed symptoms in the form of transient ischemic attacks or had a posterior hemispheric stroke. Traditional treatment of VAD has been surgical. More recently, endovascular treatment of VAD has been utilized. We performed a retrospective review of our institutional experience in treating VAD from 2001 to 2010. For treatment of proximal VAD, perioperative morbidity is lower for the endovascular group than for the surgical group, but six-week mortality was higher for the endovascular group. Complete resolution of symptoms occurred more frequently with surgery than with endovascular therapy. Therefore surgical reconstruction appears to be preferable to angioplasty and stenting for treatment of proximal vertebral artery occlusive disease.


Subject(s)
Angioplasty, Balloon , Vascular Surgical Procedures , Vertebral Artery/surgery , Vertebrobasilar Insufficiency/therapy , Aged , Aged, 80 and over , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/instrumentation , Angioplasty, Balloon/mortality , Female , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome , Vascular Patency , Vascular Surgical Procedures/adverse effects , Vascular Surgical Procedures/mortality , Vertebral Artery/diagnostic imaging , Vertebral Artery/physiopathology , Vertebrobasilar Insufficiency/complications , Vertebrobasilar Insufficiency/diagnosis , Vertebrobasilar Insufficiency/mortality , Vertebrobasilar Insufficiency/physiopathology , Vertebrobasilar Insufficiency/surgery
5.
Proc (Bayl Univ Med Cent) ; 26(2): 100-2, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23543961

ABSTRACT

The use of thermoregulatory catheters (TRCs) in critically ill patients has become increasingly popular. TRCs have been shown to be effective in regulating patient body temperature with improved outcomes. Critically ill patients, especially multitrauma patients and those with femoral catheters, are at high risk for deep vein thrombosis (DVT). Among patients for whom chemical DVT prophylaxis is not an option, inferior vena cava (IVC) filters are often placed prophylactically. The development of intravascular ultrasound (IVUS) has allowed placement of IVC filters at the bedside for patients who are too ill for transport to the operating room or cardiac catheterization lab. After encountering several patients with occult DVT of the IVC during bedside IVC filter placement, we performed a retrospective review to determine the incidence of DVT or pulmonary embolus (PE) in patients who had been treated with a TRC at Baylor University Medical Center at Dallas. Since 2008, IVC filters have been deployed at the bedside with the use of IVUS at Baylor University Medical Center. During that same time period, 83 patients had a TRC placed for either intravascular warming or cooling during their resuscitation. Forty-seven out of 83 patients who had a TRC placed survived their injuries. Ten of 47 patients (21%) were diagnosed with DVT or PE, and 6 of these 10 (60%) were found to have caval thrombus. We present this case series as evidence that undiagnosed IVC thrombus associated with TRCs may be higher than previously suspected, given that 5 out of 10 patients who had IVUS of their IVC for prophylactic IVC filter placement, as well as one patient diagnosed with PE, were found to have caval thrombus.

SELECTION OF CITATIONS
SEARCH DETAIL
...