1.
J Crit Care ; 79: 154464, 2024 02.
Article in English | MEDLINE | ID: mdl-37948943

ABSTRACT

PURPOSE: Evaluate optic nerve sheath and pial diameters (ONSD, ONPD) via sonography and computed tomography (CT) after out-of-hospital cardiac arrest (CA) and to compare their prognostic significance with other imaging and laboratory biomarkers. MATERIALS AND METHODS: A prospective observational study enrolling patients after successful resuscitation between December 2017 and August 2021. ONSD and ONPD were measured with sonography. Additionally, ONSD, and also grey-to-white ratio at basal ganglia (GWRBG) and cerebrum (GWRCBR), were assessed using CT. Lactate and neuron specific enolase (NSE) blood levels were measured. RESULTS: Sonographically measured ONSD and ONPD yielded no significant difference between survival and non-survival (p values ≥0.4). Meanwhile, CT assessed ONSD, GWRBG, GWRCBR, and NSE levels significantly differed regarding both, survival (p values ≤0.005) and neurological outcome groups (p values ≤0.04). For survival prognosis, GWRBG, GWRCBR, and NSE levels appeared as excellent predictors; in predicting a good neurological outcome, NSE had the highest accuracy. CONCLUSIONS: CT diagnostics, in particular GWRBG and GWRCBR, as well as NSE as laboratory biomarker, appear as excellent outcome predictors. Meanwhile, our data lead us to recommend caution in utilizing sonography assessed ONSD and ONPD for prognostic decision-making post-CA.


Subject(s)
Out-of-Hospital Cardiac Arrest , Humans , Out-of-Hospital Cardiac Arrest/diagnostic imaging , Out-of-Hospital Cardiac Arrest/therapy , Optic Nerve/diagnostic imaging , Prospective Studies , Prognosis , Tomography, X-Ray Computed/methods
3.
AJR Am J Roentgenol ; 214(2): 422-427, 2020 02.
Article in English | MEDLINE | ID: mdl-31799871

ABSTRACT

OBJECTIVE. The purpose of this study was to assess image quality and radiation dose of a novel twin robotic x-ray system's 3D cone-beam CT (CBCT) function for the depiction of cadaveric wrists. MATERIALS AND METHODS. Sixteen cadaveric wrists were scanned using dedicated low-dose and standard-dose CBCT protocols as well as clinical MDCT for comparison. Three readers assessed overall image quality, noise, and artifacts in bone and soft tissue on 5-point Likert scales. For radiation dose analysis, volume CT dose indexes (CTDIvol) were compared. RESULTS. Overall image quality of most studies was very good or excellent in MDCT (for readers 1, 2, and 3: 100%, 100%, and 88%, respectively), standard-dose CBCT (100%, 100%, and 94%), and low dose CBCT (100%, 94%, and 88%) with two readers favoring standard-dose CBCT over MDCT image quality (readers 1 and 2; p ≤ 0.046). In soft tissue, standard-dose (readers 1, 2, and 3; p ≤ 0.021) and low-dose (all p ≤ 0.001) CBCT images had more noise than MDCT in all cases. Standard-dose (all p ≤ 0.003) and low-dose (all p < 0.001) CBCT images also displayed more artifacts. In osseous tissue, one reader observed more noise (p < 0.001) and artifacts (p = 0.020) for low-dose CBCT than for MDCT, whereas no difference was found between standard-dose CBCT and MDCT. Mean CTDIvol was significantly lower for standard-dose (5.2 ± 0.6 mGy; p < 0.001) and low-dose CBCT (1.8 ± 0.2 mGy; p < 0.001) than for clinical MDCT without automatic dose modulation (15.0 ± 0.0 mGy). CONCLUSION. The tested CBCT function delivers suitable image quality for clinical wrist imaging at significantly lower radiation levels than conventional MDCT. In combination with comfortable positioning options and the ability to perform additional radiographic and fluoroscopic examinations, the twin robotic x-ray system may hold the potential to be a one-stop shop device for trauma-associated wrist imaging.


Subject(s)
Cone-Beam Computed Tomography/methods , Imaging, Three-Dimensional/methods , Radiation Dosage , Robotics , Wrist Joint/diagnostic imaging , Artifacts , Cadaver , Humans , Patient Positioning