1.
Med Phys ; 51(1): 579-590, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37166067

ABSTRACT

BACKGROUND: Numerical 4D phantoms, together with associated ground truth motion, offer a flexible and comprehensive data set for realistic simulations in radiotherapy and radiology in target sites affected by respiratory motion. PURPOSE: We present an openly available upgrade to previously reported methods for generating realistic 4DCT lung numerical phantoms, which now incorporate respiratory ribcage motion and improved lung density representation throughout the breathing cycle. METHODS: Density information of reference CTs, toget her with motion from multiple breathing cycle 4DMRIs have been combined to generate synthetic 4DCTs (4DCT(MRI)s). Inter-subject correspondence between the CT and MRI anatomy was first established via deformable image registration (DIR) of binary masks of the lungs and ribcage. Ribcage and lung motions were extracted independently from the 4DMRIs using DIR and applied to the corresponding locations in the CT after post-processing to preserve sliding organ motion. In addition, based on the Jacobian determinant of the resulting deformation vector fields, lung densities were scaled on a voxel-wise basis to more accurately represent changes in local lung density. For validating this process, synthetic 4DCTs, referred to as 4DCT(CT)s, were compared to the originating 4DCTs using motion extracted from the latter, and the dosimetric impact of the new features of ribcage motion and density correction were analyzed using pencil beam scanned proton 4D dose calculations. RESULTS: Lung density scaling led to a reduction of maximum mean lung Hounsfield units (HU) differences from 45 to 12 HU when comparing simulated 4DCT(CT)s to their originating 4DCTs. Comparing 4D dose distributions calculated on the enhanced 4DCT(CT)s to those on the original 4DCTs yielded 2%/2 mm gamma pass rates above 97% with an average improvement of 1.4% compared to previously reported phantoms. CONCLUSIONS: A previously reported 4DCT(MRI) workflow has been successfully improved and the resulting numerical phantoms exhibit more accurate lung density representations and realistic ribcage motion.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Humans , Four-Dimensional Computed Tomography/methods , Lung/diagnostic imaging , Radiometry/methods , Respiration , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods
2.
Med Phys ; 49(5): 2890-2903, 2022 May.
Article in English | MEDLINE | ID: mdl-35239984

ABSTRACT

PURPOSE: Respiratory motion is one of the major challenges in radiotherapy. In this work, a comprehensive and clinically plausible set of 4D numerical phantoms, together with their corresponding "ground truths," have been developed and validated for 4D radiotherapy applications. METHODS: The phantoms are based on CTs providing density information and motion from multi-breathing-cycle 4D Magnetic Resonance imagings (MRIs). Deformable image registration (DIR) has been utilized to extract motion fields from 4DMRIs and to establish inter-subject correspondence by registering binary lung masks between Computer Tomography (CT) and MRI. The established correspondence is then used to warp the CT according to the 4DMRI motion. The resulting synthetic 4DCTs are called 4DCT(MRI)s. Validation of the 4DCT(MRI) workflow was conducted by directly comparing conventional 4DCTs to derived synthetic 4D images using the motion of the 4DCTs themselves (referred to as 4DCT(CT)s). Digitally reconstructed radiographs (DRRs) as well as 4D pencil beam scanned (PBS) proton dose calculations were used for validation. RESULTS: Based on the CT image appearance of 13 lung cancer patients and deformable motion of five volunteer 4DMRIs, synthetic 4DCT(MRI)s with a total of 871 different breathing cycles have been generated. The 4DCT(MRI)s exhibit an average superior-inferior tumor motion amplitude of 7 ± 5 mm (min: 0.5 mm, max: 22.7 mm). The relative change of the DRR image intensities of the conventional 4DCTs and the corresponding synthetic 4DCT(CT)s inside the body is smaller than 5% for at least 81% of the pixels for all studied cases. Comparison of 4D dose distributions calculated on 4DCTs and the synthetic 4DCT(CT)s using the same motion achieved similar dose distributions with an average 2%/2 mm gamma pass rate of 90.8% (min: 77.8%, max: 97.2%). CONCLUSION: We developed a series of numerical 4D lung phantoms based on real imaging and motion data, which give realistic representations of both anatomy and motion scenarios and the accessible "ground truth" deformation vector fields of each 4DCT(MRI). The open-source code and motion data allow foreseen users to generate further 4D data by themselves. These numeric 4D phantoms can be used for the development of new 4D treatment strategies, 4D dose calculations, DIR algorithm validations, as well as simulations of motion mitigation and different online image guidance techniques for both proton and photon radiation therapy.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Four-Dimensional Computed Tomography/methods , Humans , Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Protons , Respiration , Tomography, X-Ray Computed
3.
Phys Med Biol ; 66(3): 035011, 2021 01 26.
Article in English | MEDLINE | ID: mdl-33238246

ABSTRACT

Pencil beam scanned (PBS) proton therapy of lung tumours is hampered by respiratory motion and the motion-induced density changes along the beam path. In this simulation study, we aim to investigate the effectiveness of proton beam tracking for lung tumours both under ideal conditions and in conjunction with a respiratory motion model guided by real-time ultrasound imaging of the liver. Multiple-breathing-cycle 4DMRIs of the thorax and abdominal 2D ultrasound images were acquired simultaneously for five volunteers. Deformation vector fields extracted from the 4DMRI, referred to as ground truth motion, were used to generate 4DCT(MRI) data sets of two lung cancer patients, resulting in 10 data sets with variable motion patterns. Given the 4DCT(MRI) and the corresponding ultrasound images as surrogate data, a patient-specific motion model was built. The model consists of an autoregressive model and Gaussian process regression for the temporal and spatial prediction, respectively. Two-field PBS plans were optimised on the reference CTs, and 4D dose calculations (4DDC) were used to simulate dose delivery for (a) unmitigated motion, (b) ideal 2D and 3D tracking (both beam adaption and 4DDC based on ground truth motion), and (c) realistic 2D and 3D tracking (beam adaption based on motion predictions, 4DDC on ground truth motion). Model-guided tracking retrieved clinically acceptable target dose homogeneity, as seen in a substantial reduction of the D5%-D95% compared to the non-mitigated simulation. Tracking in 2D and 3D resulted in a similar improvement of the dose homogeneity, as did ideal and realistic tracking simulations. In some cases, however, the tracked deliveries resulted in a shift towards higher or lower dose levels, leading to unacceptable target over- or under-coverage. The presented motion modelling framework was shown to be an accurate motion prediction tool for the use in proton beam tracking. Tracking alone, however, may not always effectively mitigate motion effects, making it necessary to combine it with other techniques such as rescanning.


Subject(s)
Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Proton Therapy/methods , Radiotherapy, Image-Guided/methods , Feasibility Studies , Four-Dimensional Computed Tomography , Humans , Lung Neoplasms/physiopathology , Magnetic Resonance Imaging , Respiration , Ultrasonography
4.
Phys Med Biol ; 65(23): 235050, 2020 12 22.
Article in English | MEDLINE | ID: mdl-32721930

ABSTRACT

Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We present its effects on 4D pencil beam scanned treatment planning and simulated dose distributions. Given an ultrasound image of the liver and the diaphragm, principal component analysis and Gaussian process regression were applied to infer dense motion information of the lungs. 4D dose calculations for scanned proton therapy were performed using the estimated and the corresponding ground truth respiratory motion; the differences were compared by dose difference volume metrics. We performed this simulation study on 10 combined CT and 4DMRI data sets where the motion characteristics were extracted from 5 healthy volunteers and fused with the anatomical CT data of two lung cancer patients. Median geometrical estimation errors below 2 mm for all data sets and maximum dose differences of [Formula: see text] = 43.2% and [Formula: see text] = 16.3% were found. Moreover, it was shown that abdominal ultrasound imaging allows to monitor organ drift. This study demonstrated the feasibility of the proposed ultrasound-based motion modelling approach for its application in scanned proton therapy of lung tumours.


Subject(s)
Four-Dimensional Computed Tomography/methods , Liver/diagnostic imaging , Lung Neoplasms/radiotherapy , Magnetic Resonance Imaging/methods , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Ultrasonography/methods , Humans , Lung Neoplasms/diagnostic imaging , Movement , Respiration
5.
Radiother Oncol ; 145: 154-161, 2020 04.
Article in English | MEDLINE | ID: mdl-32007759

ABSTRACT

PURPOSE: Motion management is crucial in scanned proton therapy for mobile tumours. Current motion mitigation approaches rely on single 4DCTs before treatment, ignoring respiratory variability. We investigate the consequences of respiratory variations on internal target volumes (ITV) definition and motion mitigation efficacy, and propose a probabilistic ITV based on 4DMRI. MATERIALS AND METHODS: Four 4DCT(MRI) datasets, each containing 40 variable cycles of synthetic 4DCTs, were generated by warping single-phase CTs of two lung patients with motion fields extracted from two 4DMRI datasets. Two-field proton treatment plans were optimised on ITVs based on different parts of the 4DCT(MRI)s. 4D dose distributions were calculated by considering variable respiratory patterns. Different probabilistic ITVs were created by incorporating the voxels covered by the CTV in at least 25%, 50%, or 75% (ITV25, ITV50, ITV75) of the cycles, and compared with the conservative ITV encompassing all possible CTV positions. RESULTS: Depending on the selected planning 4DCT, ITV volumes vary up to 20%, resulting in significant variation in CTV coverage for 4D treatments. Target coverage and homogeneity improved with the conservative ITV, but was associated with significantly increased lung dose (~1%). ITV25 and ITV50 led to acceptable plan quality in most cases without lung dose increments. ITV75 best minimised lung dose, but was insufficient to ensure coverage under all motion scenarios. CONCLUSION: Irregular respiration significantly affects CTV coverage when ITVs are only defined by single 4DCTs. A probabilistic ITV50 provides an adequate compromise between target coverage and lung dose for most motion and patient scenarios investigated.


Subject(s)
Lung Neoplasms , Proton Therapy , Four-Dimensional Computed Tomography , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Protons , Radiotherapy Planning, Computer-Assisted , Respiration
6.
PLoS One ; 14(6): e0218776, 2019.
Article in English | MEDLINE | ID: mdl-31251762

ABSTRACT

Monitoring subtle choroidal thickness changes in the human eye delivers insight into the pathogenesis of various ocular diseases such as myopia and helps planning their treatment. However, a thorough evaluation of detection-performance is challenging as a ground truth for comparison is not available. Alternatively, an artificial ground truth can be generated by averaging the manual expert segmentations. This makes the ground truth very sensitive to ambiguities due to different interpretations by the experts. In order to circumvent this limitation, we present a novel validation approach that operates independently from a ground truth and is uniquely based on the common agreement between algorithm and experts. Utilizing an appropriate index, we compare the joint agreement of several raters with the algorithm and validate it against manual expert segmentation. To illustrate this, we conduct an observational study and evaluate the results obtained using our previously published registration-based method. In addition, we present an adapted state-of-the-art evaluation method, where a paired t-test is carried out after leaving out the results of one expert at the time. Automated and manual detection were performed on a dataset of 90 OCT 3D-volume stack pairs of healthy subjects between 8 and 18 years of age from Asian urban regions with a high prevalence of myopia.


Subject(s)
Choroid/diagnostic imaging , Imaging, Three-Dimensional/methods , Tomography, Optical Coherence/methods , Adolescent , Algorithms , Child , Female , Healthy Volunteers , Humans , Male , Models, Statistical
7.
Phys Med Biol ; 63(14): 145015, 2018 07 16.
Article in English | MEDLINE | ID: mdl-29864021

ABSTRACT

We present an ultrasound-driven 4D magnetic resonance imaging (US-4DMRI) method for respiratory motion imaging in the thorax and abdomen. The proposed US-4DMRI comes along with a high temporal resolution, and allows for organ motion imaging beyond a single respiratory cycle. With the availability of the US surrogate both inside and outside the MR bore, 4D MR images can be reconstructed for 4D treatment planning and online respiratory motion prediction during radiotherapy. US-4DMRI relies on simultaneously acquired 2D liver US images and abdominal 2D MR multi-slice scans under free respiration. MR volumes are retrospectively composed by grouping the MR slices corresponding to the most similar US images. We present two different US similarity metrics: an intensity-based approach, and a similarity measure relying on predefined fiducials which are being tracked over time. The proposed method is demonstrated on MR liver scans of eight volunteers acquired over a duration of 5.5 min each at a temporal resolution of 2.6 Hz with synchronous US imaging at 14 Hz-17 Hz. Visual inspection of the reconstructed MR volumes revealed satisfactory results in terms of continuity in organ boundaries and blood vessels. In quantitative leave-one-out experiments, both US similarity metrics reach the performance level of state-of-the-art navigator-based approaches.


Subject(s)
Abdomen/diagnostic imaging , Four-Dimensional Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , Thorax/diagnostic imaging , Ultrasonography/methods , Humans , Movement , Respiration , Retrospective Studies
8.
Int J Comput Assist Radiol Surg ; 12(10): 1751-1762, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28258401

ABSTRACT

PURPOSE: The use of a robot-guided laser osteotome for median sternotomy is impeded by prohibiting cutting inaccuracies due to respiration-induced motions of the thorax. With this paper, we advance today's methodologies in sternotomy procedures by introducing the concept of novel 3D functional cuts and a respiratory motion compensation algorithm for the computer-assisted and robot-guided laser osteotome, CARLO®. METHODS: We present a trajectory planning algorithm for performing 3D functional cuts at a constant cutting velocity. In addition, we propose the use of Gaussian process (GP) prediction in order to anticipate the sternum's pose providing enough time for the CARLO® device to adjust the position of the laser source. RESULTS: We analysed the performance of the proposed algorithms on a computer-based simulation framework of the CARLO® device. The median position error of the laser focal point has shown to be reduced from 0.22 mm without GP prediction to 0.19 mm with GP prediction. CONCLUSION: The encouraging simulation results support the proposed respiratory motion compensation algorithm for robot-guided laser osteotomy on the thorax. Successful compensation of the respiration-induced motion of the thorax opens doors for robot-guided laser sternotomy and the related novel cutting patterns. These functional cuts hold great potential to significantly improve postoperative sternal stability and therefore reduce pain and recovery time for the patient. By enabling functional cuts, we approach an important threshold moment in the history of osteotomy, creating innovative opportunities which reach far beyond the classic linear cutting patterns.


Subject(s)
Algorithms , Computer Simulation , Osteotomy/instrumentation , Respiration , Robotics/instrumentation , Sternotomy/methods , Humans , Imaging, Three-Dimensional , Laser Therapy , Motion