1.
Rev Bras Ter Intensiva ; 34(3): 351-359, 2022.
Article in Portuguese, English | MEDLINE | ID: mdl-36351067

ABSTRACT

OBJECTIVE: To develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost. METHODS: The device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided. RESULTS: The pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period. CONCLUSION: This ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.


OBJETIVO: Desenvolver um ventilador mecânico invasivo simples, resistente, seguro e eficiente que possa ser utilizado em áreas remotas do mundo ou zonas de guerra, em que a utilidade prática de equipamentos mais sofisticados é limitada por questões de manutenção, disponibilidade de peças, transporte e/ou custo. MÉTODOS: O dispositivo implementa o modo de ventilação mandatória contínua com pressão controlada, complementado por um simples modo assisto-controlado. Pode-se também utilizar a pressão positiva contínua nas vias aéreas. Ao se evitar o fluxo contínuo de oxigênio ou ar, minimiza-se o consumo de gases comprimidos. As taxas respiratórias e as relações de tempo de inspiração e expiração são determinadas eletronicamente. Além disso, conta com um alarme de apneia/falta de energia. RESULTADOS: Os perfis de pressão foram medidos para uma série de condições, sendo considerados ajustáveis dentro de uma margem de erro de ± 2,5cmH2O, e foram considerados bem estáveis dentro dessa variação durante um período de 41 horas. Os parâmetros de tempo do ciclo respiratório foram precisos dentro de alguns pontos percentuais durante o mesmo período. O dispositivo foi testado quanto à durabilidade por um período equivalente a 4 meses. Os testes químicos e biológicos não conseguiram identificar qualquer contaminação do gás por compostos orgânicos voláteis ou micro-organismos. Em comparação com um ventilador bem estabelecido, o teste de ventilação em um animal de grande porte mostrou que este poderia ser ventilado adequadamente durante um período de 60 minutos, sem quaisquer efeitos negativos perceptíveis durante o período subsequente de 24 horas. CONCLUSÃO: Este projeto de ventilador pode ser viável após novos testes em animais e aprovação formal pelas autoridades competentes, para aplicação clínica nas circunstâncias atípicas anteriormente mencionadas.


Subject(s)
Continuous Positive Airway Pressure , Ventilators, Mechanical , Animals , Humans , Respiration, Artificial
2.
Rev. bras. ter. intensiva ; 34(3): 351-359, jul.-set. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1407751

ABSTRACT

RESUMO Objetivo: Desenvolver um ventilador mecânico invasivo simples, resistente, seguro e eficiente que possa ser utilizado em áreas remotas do mundo ou zonas de guerra, em que a utilidade prática de equipamentos mais sofisticados é limitada por questões de manutenção, disponibilidade de peças, transporte e/ou custo. Métodos: O dispositivo implementa o modo de ventilação mandatória contínua com pressão controlada, complementado por um simples modo assisto-controlado. Pode-se também utilizar a pressão positiva contínua nas vias aéreas. Ao se evitar o fluxo contínuo de oxigênio ou ar, minimiza-se o consumo de gases comprimidos. As taxas respiratórias e as relações de tempo de inspiração e expiração são determinadas eletronicamente. Além disso, conta com um alarme de apneia/falta de energia. Resultados: Os perfis de pressão foram medidos para uma série de condições, sendo considerados ajustáveis dentro de uma margem de erro de ± 2,5cmH2O, e foram considerados bem estáveis dentro dessa variação durante um período de 41 horas. Os parâmetros de tempo do ciclo respiratório foram precisos dentro de alguns pontos percentuais durante o mesmo período. O dispositivo foi testado quanto à durabilidade por um período equivalente a 4 meses. Os testes químicos e biológicos não conseguiram identificar qualquer contaminação do gás por compostos orgânicos voláteis ou micro-organismos. Em comparação com um ventilador bem estabelecido, o teste de ventilação em um animal de grande porte mostrou que este poderia ser ventilado adequadamente durante um período de 60 minutos, sem quaisquer efeitos negativos perceptíveis durante o período subsequente de 24 horas. Conclusão: Este projeto de ventilador pode ser viável após novos testes em animais e aprovação formal pelas autoridades competentes, para aplicação clínica nas circunstâncias atípicas anteriormente mencionadas.


ABSTRACT Objective: To develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost. Methods: The device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided. Results: The pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period. Conclusion: This ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.

3.
Parasitol. latinoam ; 61(1/2): 94-97, jun. 2006.
Article in Spanish | LILACS | ID: lil-432856

ABSTRACT

Las diversas inquietudes planteadas por pacientes chagásicos crónicos en relación a su condición clínica, motivaron a un grupo de parasitólogos a diseñar un programa de intervención educativa. Participaron en forma voluntaria 72 pacientes, 32 hombres y 40 mujeres, procedentes de zona de alta y baja endemia chagásica de Chile. La metodología docente consistió fundamentalmente en: aplicación de test diagnóstico y de conocimientos adquiridos; sesiones teóricas que abordaron seis temáticas relacionadas; actividades prácticas tutoriales; utilización de material audiovisual e impreso; atención personalizada por médico parasitólogo (posterior a la intervención educativa y con los antecedentes serológicos, electrocardiográficos y parasitológicos previamente determinados) y evaluación de la actividad educativa por parte de los pacientes. Un mayor conocimiento previo y adquirido se observó en chagásicos crónicos procedentes de zonas endémicas. Todos demos-traron un alto grado de interés y participaron activamente de las actividades programadas. La metodología utilizada, el trabajo tutorial de pequeño grupo y la atención-orientación individual por parte del médico parasitólogo, facilitaron el proceso de enseñanza-aprendizaje. Se concluye que la intervención educativa responde a muchas de las interrogantes respecto de la afección, permite al paciente reconocer el rol que le cabe como protagonista de su propio bienestar y lo transforma en un eficaz agente en el control de la enfermedad de Chagas.


Subject(s)
Humans , Male , Adult , Female , Patient Education as Topic , Chagas Disease , Chile , Health Education , Chronic Disease
4.
Rev Med Chil ; 132(8): 939-46, 2004 Aug.
Article in Spanish | MEDLINE | ID: mdl-15478295

ABSTRACT

UNLABELLED: Serum antibodies against Trypanosoma Cruzi have been observed in 19% of the Chilean population. Marked differences in organ involvement have been reported in patients with Chagas disease. Chagas disease is rarely an aetiological factor for achalasia in Chile, which is different from reports in other countries of South America. In contrast, a high incidence of megacolon among these patients have been reported. AIM: To study the incidence of gastric and small intestinal motor disorders among these patients and their relationship to esophageal and colon motility disorders. PATIENTS AND METHODS: We studied 18 patients, 12 women (mean age 45 years); with positive antibodies against T. Cruzi. Seven had radiological evidence of megacolon and no one had radiological or manometric evidence for achalasia. Non specific motor esophageal abnormalities were found in 11 patients. Nine had an abnormal electrocardiogram, suggesting a myocardial disease. A questionnaire for gastrointestinal symptoms, an electrogastrography and a small intestinal motility study, were performed in each patient. RESULTS: All patients had evidences of abnormalities in at least one segment of the digestive tract. Twelve patients had an abnormal electrogastrographic study, with bradygastria as the most common finding. Nine had an abnormal small intestinal manometry with a myophatic pattern evidenced by a decreased amplitude of contractions (18.5 +/- 3 mmHg). Also an increased number of clustered contractions was observed. CONCLUSIONS: Gastric dysrhythmias and small intestinal motor abnormalities are frequently associated to non specific esophageal motor disorders and megacolon in patients with Chagas disease.


Subject(s)
Chagas Disease/physiopathology , Gastrointestinal Motility/physiology , Adolescent , Adult , Aged , Chagas Cardiomyopathy/physiopathology , Chile , Esophageal Achalasia/physiopathology , Female , Humans , Incidence , Intestine, Small/physiology , Male , Megacolon/physiopathology , Middle Aged
5.
Parasitol. latinoam ; 59(3/4): 93-98, jul. 2004. tab
Article in Spanish | LILACS | ID: lil-396119

ABSTRACT

En el año 1999, se certificó en Chile la interrupción de la transmisión vectorial de la enfermedad de Chagas. Por otra parte, el desarrollo de políticas habitacionales, que incluyen zonas rurales endémicas, han logrado importantes avances en grupos humanos que presentaban graves deficiencias de habitabilidad. En esta situación epidemiológica, se estudió 10 años después de la terapia, a 37 chagásicos crónicos procedentes de zonas rurales de la IV Región, mediante encuesta epidemiológica (pre y post-terapia) y evaluación parasitológica (post-terapia). La encuesta incluyó: conocimiento del vector, triatominos en el domicilio actual, antecedentes de haber sido picado por triatominos y material de la construcción de la vivienda. La evaluación parasitológica se realizó mediante xenodiagnóstico (XD) (37 casos) y Reacción en Cadena de la Polimerasa (PCR) en sangre periférica (34 casos). Los resultados de la encuesta epidemiológica evidenciaron cambios importantes en la calidad de la vivienda rural de los chagásicos tratados, mientras que, en relación a la parasitemia, se detectó Trypanosoma cruzi circulante en el 89,2 por ciento de los casos (37,8 por ciento y 88,2 por ciento, mediante XD y PCR, respectivamente). Se concluye que la persistencia del parásito en condiciones post-terapia, no está relacionada con la presencia de Triatoma infestans intradomiciliario.


Subject(s)
Adult , Male , Humans , Female , Chagas Disease/diagnosis , Insect Vectors , Parasitemia/diagnosis , Triatoma/physiology , Trypanosoma cruzi/genetics , Chronic Disease , Chile/epidemiology , Enzyme-Linked Immunosorbent Assay , Chagas Disease/parasitology , Fluorescent Antibody Technique, Direct , Follow-Up Studies , Health Surveys , Polymerase Chain Reaction , Rural Areas , Xenodiagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...