Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Clín. investig. ginecol. obstet. (Ed. impr.) ; 40(5): 207-212, sept.-oct. 2013. ilus, tab
Article in Spanish | IBECS | ID: ibc-115864

ABSTRACT

Objetivo: Se determinaron los valores de la frecuencia cardiaca y la incidencia de dips tipos i y ii en los fetos con circular de cordón. Diseño del estudio La muestra la integraron 40 pacientes, se dividió en 2 grupos: Grupo 1: 20 pacientes embarazadas con diagnóstico de circular de cordón o grupo problema; Grupo 2: 20 pacientes con embarazo normal o grupo testigo. Se practicaron registros de frecuencia cardiaca fetal y contractilidad uterina durante 2 h. Para el análisis estadístico se utilizaron el programa SPSS® y las pruebas t de Student y Z. Resultados En el grupo problema la frecuencia cardiaca fetal (FCF) fue de 138 latidos por minuto (lat/min) y en el testigo de 135 lat/min. En el primer grupo, esta se incrementó 3 lat. Se calculó si la diferencia entre medias era o no significativa. Se utilizaron las pruebas de Z-score cuyo valor fue de 8,65 y p < 0,01: esta fue significativa. En los 2 grupos se calcularon los valores de la amplitud de las aceleraciones. Estas fueron semejantes: 24 lat. La diferencia entre medias no fue significativa. El análisis comparativo entre el peso y la talla de los recién nacidos en el grupo problema fue de 3.100 g y la talla de 50,72 cm. En el testigo fue de 2.960 g y 49,77 cm respectivamente. La diferencia entre medias no fue significativa. A los recién nacidos se les valoró con la prueba de Apgar. En el grupo problema, durante el primer minuto la calificación tuvo un rango de 7-9 y en el quinto de 8-9. En el grupo testigo las calificaciones fueron semejantes. Se cuantificaron los dips tipos i y ii . De los primeros dips se registraron 3 y de los segundos 2, uno con gran amplitud y duración. No se registraron dips tipo iii . En ninguno de los partos hubo presencia de meconio. Conclusiones En la circular de cordón floja: no hubo cambios significativos en la FCF. Circular de cordón apretada produjo: dips tipo ii de gran amplitud (AU)


Objective: To determine heart rate and the frequency of type i and ii dips in fetuses with coiling of funis. Study design: There were 40 patients in the sample, divided in two groups: group 1: consisted of 20 pregnant women with a diagnosis of coiling of funis; group ii consisted of 20 patients with a normal pregnancy. Fetal heart rate (HR) and uterine contractility were recorded for 2 hours. For the statistical analysis, the SPSS® package, Z-score and Student’s t-test were used. Results: Fetal HR was 138 beats/min in group 1 and 135 beats/min in group ii. The difference between medians (Z-score) was 8.65, which was significant (P<.01).Amplitude and accelerations were calculated in both groups, with similar results (24 beats).The difference in means was not significant. The mean weight and height were compared in the two groups. Mean weight was 3,100 g in group 1 and 2,960 in group 1, while mean height was 50.72 cm in group i and 49.77 in group 2.The difference in means was not significant. Apgar tests were performed in both groups. In group 1, Apgar scores ranged from 7-9 at1 minute and from 8-9 at 5 minutes. Values were similar in group 2.Type i dips gave a reading of 3, and type ii dips a reading of 2 (one with marked height and duration). No type iii dips were observed. No meconium was found in any of the deliveries. Conclusions: In pregnancies with loosely coiled funises, there were no significant changes in fetal HR. In pregnancies with tightly coiled funises, type ii dips with wide amplitude and marked duration were found (AU)


Subject(s)
Humans , Female , Pregnancy , Nuchal Cord/physiopathology , Heart Rate, Fetal/physiology , Fetal Hypoxia/physiopathology , Uterine Contraction/physiology , Case-Control Studies , Risk Factors , Obstetric Labor Complications
SELECTION OF CITATIONS
SEARCH DETAIL
...