Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Biochem Rev ; 37(2): 63-84, 2016 May.
Article in English | MEDLINE | ID: mdl-28303072

ABSTRACT

As an outcome of the 2010 Asian Pacific Conference for Chromatography and Mass Spectrometry in Hong Kong, a collaborative working group was formed to promote the harmonisation of mass spectrometry methods. The Mass Spectrometry Harmonisation Working Group resides under the combined auspices of the Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine (APFCB) and the Australasian Association of Clinical Biochemists (AACB). A decision was made to initially focus attention on serum steroids due to the common interest of members in this area; with the first steroid to assess being testosterone. In principle, full standardisation with traceability should be achievable for all steroids as they are small compounds with defined molecular weight and structure. In order to achieve this we need certified reference materials, reference methods, reference laboratories, reference intervals and external quality assurance programs; each being an important pillar in the process. When all the pillars are present, such as for serum testosterone, it is feasible to fully standardise the liquid chromatography - tandem mass spectrometry (LC-MS/MS) methods. In a collaborative process with interested stakeholders, we commenced on a pathway to provide ongoing assessment and seek opportunities for improvement in the LC-MS/MS methods for serum steroids. Here we discuss the outcomes to date and major challenges related to the accurate measurement of serum steroids with a focus on serum testosterone.

2.
Clin Biochem Rev ; 35(2): 81-113, 2014 May.
Article in English | MEDLINE | ID: mdl-25210208

ABSTRACT

Despite apparent method similarities between laboratories there appear to be confounding factors inhibiting uniform reporting and standardisation of vitamin assays. The Australasian Association of Clinical Biochemists (AACB) Vitamins Working Party, in conjunction with The Royal College of Pathologists of Australasia Quality Assurance Programs, has formulated a guideline to improve performance, reproducibility and accuracy of fat-soluble vitamin results. The aim of the guideline is to identify critical pre-analytical, analytical and post-analytical components of the analysis of vitamins A, E and carotenoids in blood to promote best practice and harmonisation. This best practice guideline has been developed with reference to the Centers for Disease Control and Prevention (CDC) "Laboratory Medicine Best Practices: Developing an Evidence-Based Review and Evaluation Process". The CDC document cites an evaluation framework for generating best practice recommendations that are specific to laboratory medicine. These 50 recommendations proposed herein, were generated from a comprehensive literature search and the extensive combined experience of the AACB Vitamins Working Party members. They were formulated based on comparison between an impact assessment rating and strength of evidence and were classified as either: (1) strongly recommend, (2) recommend, (3) no recommendation for or against, or (4) recommend against. These best practice recommendations represent the consensus views, in association with peer reviewed evidence of the AACB Vitamins Working Party, towards best practice for the collection, analysis and interpretation of vitamins A, E and carotenoids in blood.

3.
Clin Biochem ; 46(9): 772-6, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23388676

ABSTRACT

OBJECTIVES: The RCPA Quality Assurance Program (RCPA QAP) offers monthly proficiency testing for vitamins A, B1, B6, ß-carotene, C and E to laboratories worldwide. A review of the results submitted for the whole blood vitamin B1/B6 sub-program revealed a wide dispersion. Here we describe the results of a methodology survey for vitamins B1 and B6. DESIGN AND METHODS: A questionnaire was sent to thirteen laboratories. Eleven laboratories were returning QAP results for vitamin B1 (thiamine diphosphate) and five were returning results for vitamin B6 (pyridoxal-5-phosphate). RESULTS: All nine respondents provided a clinical service for vitamins B1 and B6. HPLC with fluorescence detection was the most common method principle. For vitamin B1, six respondents used a commercial assay whilst three used in-house methods; whole blood was the matrix for all. For vitamin B6, five respondents used commercial assays and four used in-house assays. The choice of matrix for vitamin B6 varied with three respondents using whole blood and five using plasma for analysis. Sample preparation incorporated protein precipitation and derivatization steps. An internal standard was employed in sample preparation by only one survey respondent. CONCLUSIONS: The immediate result of this survey was the incorporation of plasma vitamin B6 into the RCPA QAP vitamin program. The absence of an internal standard in current vitamin B1 and B6 assays is a likely contributor to the wide dispersion of results seen in this program. We recommend kit manufacturers and laboratories investigate the inclusion of internal standards to correct the variability that may occur during processing.


Subject(s)
Blood Chemical Analysis/standards , Laboratory Proficiency Testing , Thiamine/blood , Vitamin B 6/blood , Chromatography, High Pressure Liquid/standards , Humans , Reference Values , Surveys and Questionnaires
5.
Clin Biochem Rev ; 31(3): 105-9, 2010 Aug.
Article in English | MEDLINE | ID: mdl-24150514

ABSTRACT

The Quality Assurance for Aboriginal and Torres Strait Islander Medical Services (QAAMS) Program is the largest and longest-standing national point-of-care testing (PoCT) program in Australia. With a focus on PoCT for diabetes management, it now operates in 115 Indigenous medical services and has been funded continuously by the Australian Government for 11 years. A recent independent evaluation of the QAAMS Program concluded that the program continues to meet best practice standards for Indigenous healthcare, diabetes management and PoCT.

6.
Clin Biochem Rev ; 27(4): 185-90, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17581642

ABSTRACT

Type 2 diabetes mellitus and its major complication, renal disease, represent one of the most significant contemporary health problems facing Australia's Indigenous Aboriginal People. The Australian Government-funded Quality Assurance for Aboriginal Medical Services Program (QAAMS) provides a framework by which on-site point-of-care testing (POCT) for haemoglobin A1c (HbA(1c)) and now urine albumin:creatinine ratio (ACR) can be performed to facilitate better diabetes management in Aboriginal medical services. This paper provides updated evidence for the analytical quality of POCT in the QAAMS Program. The median imprecision for point-of-care (POC) HbA(1c) and urine ACR quality assurance (QA) testing has continually improved over the past six and half years, stabilising at approximately 3% for both analytes and proving analytically sound in Aboriginal hands. For HbA(1c), there was no statistical difference between the imprecision achieved by QAAMS and laboratory users of the Bayer DCA 2000 since the QAAMS program commenced (QAAMS CV 3.6% +/- 0.52, laboratory CV 3.4% +/- 0.42; p = 0.21, paired t-test). The Western Pacific Island of Tonga recently joined the QAAMS HbA(1c) Program indicating that the QAAMS model can also be applied internationally in other settings where the prevalence of diabetes is high.

7.
Clin Biochem Rev ; 24(4): 123-30, 2003 Nov.
Article in English | MEDLINE | ID: mdl-18568052

ABSTRACT

This study describes the development, implementation and management of a multi-faceted quality assurance program called Quality Assurance for Aboriginal Medical Services (QAAMS) to support point-of-care HbA(1c) testing on the Bayer DCA 2000 in Aboriginal people with diabetes from 45 Australian Aboriginal Community Controlled Health Services. The quality assurance program comprised four elements: production of culturally appropriate education resources, formal training for Aboriginal Health Workers conducting HbA(1c) testing, an external quality assurance program and on-going quality management support services including a help hotline and an annual workshop. Aboriginal Health Workers were required to test two quality assurance (QAAMS) samples in a blind sense every month since July 1999. Samples were linearly related and comprised six paired levels of HbA(1c). The short and long term performance of each service's DCA 2000 was reviewed monthly and at the end of each six month testing cycle. The average participation rate over 7 six-monthly QAAMS testing cycles was 88%. 84% of 3100 quality assurance tests performed were within preset limits of acceptability. The median precision (CV%) for HbA(1c) testing has averaged 3.8% across the past 5 cycles (range 3.4 to 4.0%) and is continuing to improve. The introduction of a medical rebate for HbA(1c) testing has ensured the program's sustainability. Through continuing education and training, Aboriginal Health Workers have achieved consistent analytical performance for HbA(1c) testing on the DCA 2000, equivalent to that of laboratory scientists using the same instrument. This unique quality assurance model can be readily adapted to other Indigenous health settings and other point-of-care tests and instruments.

SELECTION OF CITATIONS
SEARCH DETAIL
...