Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 137
Filter
2.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38569760

ABSTRACT

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Adult , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Registries , Prosthesis Design , Retrospective Studies
4.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Article in English | MEDLINE | ID: mdl-38606564

ABSTRACT

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Treatment Outcome , Male , Female , Adolescent , Young Adult , Child , Adult , Retrospective Studies , Predictive Value of Tests , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Patient Selection , Clinical Decision-Making , Recovery of Function , Hemodynamics
5.
Catheter Cardiovasc Interv ; 103(2): 326-334, 2024 02.
Article in English | MEDLINE | ID: mdl-38149722

ABSTRACT

BACKGROUND: Atrioventricular valve regurgitation (AVVR) is a devastating complication in children and young adults with congenital heart disease (CHD), particularly in patients with single ventricle physiology. Transcatheter edge-to-edge repair (TEER) is a rapidly expanding, minimally invasive option for the treatment of AVVR in adults that avoids the morbidity and mortality associated with open heart surgery. However, application of TEER in in CHD and in children is quite novel. We describe the development of a peri-procedural protocol including image-derived pre-intervention simulation, with successful application to four patients. AIMS: To describe the initial experience using the MitraClip system for TEER of dysfunctional systemic atrioventricular valves in patients with congential heart disease within a pediatric hospital. METHODS: A standardized screening and planning process was developed using cardiac magnetic resonance imaging, three dimensional echocardiography and both virtual and physical simulation. Procedures were performed using the MitraClip G4 system and patients were clinically followed post-intervention. RESULTS: A series of four CHD patients with at least severe AVVR were screened for suitability for TEER with the MitraClip system: three patients had single ventricle physiology and Fontan palliation, and one had repair of a common atrioventricular canal defect. Each patient had at least severe systemic AVVR and was considered at prohibitively high risk for surgical repair. Each patient underwent a standardized preprocedural screening protocol and image-derived modeling followed by the TEER procedure with successful clip placement at the intended location in all cases. CONCLUSIONS: The early results of our protocolized efforts to introduce TEER repair of severe AV valve regurgitation with MitraClip into the CHD population within our institution are encouraging. Further investigations of the use of TEER in this challenging population are warranted.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Heart Septal Defects , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Child , Humans , Hospitals, Pediatric , Treatment Outcome , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Heart Septal Defects/surgery , Fontan Procedure/adverse effects , Fontan Procedure/methods , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
6.
Circ Cardiovasc Interv ; 17(1): e013204, 2024 01.
Article in English | MEDLINE | ID: mdl-38152881

ABSTRACT

BACKGROUND: Maldistribution of pulmonary blood flow in patients with congenital heart disease impacts exertional performance and pulmonary artery growth. Currently, measurement of relative pulmonary perfusion can only be performed outside the catheterization laboratory. We sought to develop a tool for measuring relative lung perfusion using readily available fluoroscopy sequences. METHODS: A retrospective cohort study was conducted on patients with conotruncal anomalies who underwent lung perfusion scans and subsequent cardiac catheterizations between 2011 and 2022. Inclusion criteria were nonselective angiogram of pulmonary vasculature, oblique angulation ≤20°, and an adequate view of both lung fields. A method was developed and implemented in 3D Slicer's SlicerHeart extension to calculate the amount of contrast that entered each lung field from the start of contrast injection and until the onset of levophase. The predicted perfusion distribution was compared with the measured distribution of pulmonary blood flow and evaluated for correlation, accuracy, and bias. RESULTS: In total, 32% (79/249) of screened studies met the inclusion criteria. A strong correlation between the predicted flow split and the measured flow split was found (R2=0.83; P<0.001). The median absolute error was 6%, and 72% of predictions were within 10% of the true value. Bias was not systematically worse at either extreme of the flow distribution. The prediction was found to be more accurate for either smaller and younger patients (age 0-2 years), for right ventricle injections, or when less cranial angulations were used (≤20°). In these cases (n=40), the prediction achieved R2=0.87, median absolute error of 5.5%, and 78% of predictions were within 10% of the true flow. CONCLUSIONS: The current study demonstrates the feasibility of a novel method for measuring relative lung perfusion using conventional angiograms. Real-time measurement of lung perfusion at the catheterization laboratory has the potential to reduce unnecessary testing, associated costs, and radiation exposure. Further optimization and validation is warranted.


Subject(s)
Lung , Humans , Infant, Newborn , Infant , Child, Preschool , Retrospective Studies , Treatment Outcome , Lung/diagnostic imaging , Lung/blood supply , Perfusion , Fluoroscopy
7.
J Am Heart Assoc ; 12(23): e030575, 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38038172

ABSTRACT

BACKGROUND: The modified Blalock-Taussig-Thomas shunt is the gold standard palliation for securing pulmonary blood flow in infants with ductal-dependent pulmonary blood flow. Recently, the ductus arteriosus stent (DAS) has become a viable alternative. METHODS AND RESULTS: This was a retrospective multicenter study of neonates ≤30 days undergoing DAS or Blalock-Taussig-Thomas shunt placement between January 1, 2017 and December 31, 2020 at hospitals reporting to the Pediatric Health Information Systems database. We performed generalized linear mixed-effects modeling to evaluate trends in intervention and intercenter variation, propensity score adjustment and inverse probability weighting with linear mixed-effects modeling to analyze length of stay and cost of hospitalization, and generalized linear mixed modeling to analyze differences in 30-day outcomes. There were 1874 subjects (58% male, 61% White) from 45 centers (29% DAS). Odds of DAS increased with time (odds ratio [OR] 1.23, annually, P<0.01 [95% CI, 1.10-1.38]) with significant intercenter variation (median OR, 3.81 [95% CI, 2.74-5.91]). DAS was associated with shorter hospital length of stay (ratio of geometric means, 0.76 [95% CI, 0.63-0.91]), shorter intensive care unit length of stay (ratio of geometric means, 0.77 [95% CI, 0.61-0.97]), and less expensive hospitalization (ratio of geometric means, 0.70 [95% CI, 0.56-0.87]). Intervention was not significantly associated with odds of 30-day transplant-free survival (OR,1.18 [95% CI, 0.70-1.99]) or freedom from catheter reintervention (OR, 1.02 [95% CI, 0.65-1.58]), but DAS was associated with 30-day freedom from composite adverse outcome (OR, 1.51 [95% CI, 1.11-2.05]). CONCLUSIONS: Use of DAS is increasing, but there is variability across centers. Though odds of transplant-free survival and reintervention were not significantly different after DAS, and DAS was associated with shorter length of stay and lower in-hospital costs.


Subject(s)
Blalock-Taussig Procedure , Ductus Arteriosus, Patent , Ductus Arteriosus , Health Information Systems , Female , Humans , Infant , Infant, Newborn , Male , Blalock-Taussig Procedure/adverse effects , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/etiology , Length of Stay , Palliative Care/methods , Pulmonary Artery , Pulmonary Circulation , Retrospective Studies , Stents , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 102(6): 1078-1087, 2023 11.
Article in English | MEDLINE | ID: mdl-37925624

ABSTRACT

BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Ventricular Outflow Obstruction, Right , Ventricular Outflow Obstruction , Humans , Swine , Animals , Heart Valve Prosthesis/adverse effects , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Treatment Outcome , Cardiac Catheterization , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Stents/adverse effects , Prosthesis Design
9.
JACC Case Rep ; 21: 101968, 2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37719290

ABSTRACT

A 38-year-old woman with sinus venosus atrial septal defect and partial anomalous return of the right upper pulmonary vein underwent a Warden procedure but experienced a large residual defect after patch dehiscence. Image-derived 3D modeling informed novel device closure with a Gore Cardioform atrial septal occluder. (Level of Difficulty: Advanced.).

10.
J Am Heart Assoc ; 12(14): e029112, 2023 07 18.
Article in English | MEDLINE | ID: mdl-37421284

ABSTRACT

Background Intensive monitoring has been associated with a lower death rate between the Norwood operation and superior cavopulmonary connection, possibly due to early identification and effective treatment of residual anatomic lesions like recoarctation before lasting harm occurs. Methods and Results Neonates undergoing a Norwood operation and receiving interstage care at a single center between January 1, 2005, and September 18, 2020, were studied. In those with recoarctation, we evaluated association of era ([1] preinterstage monitoring, [2] a transitional phase, [3] current era) and likelihood of hemodynamic compromise (progression to moderate or greater ventricular dysfunction/atrioventricular valve regurgitation, initiation/escalation of vasoactive/respiratory support, cardiac arrest preceding catheterization, or interstage death with recoarctation on autopsy). We also analyzed whether era was associated with technical success of transcatheter recoarctation interventions, major adverse events, and transplant-free survival. A total of 483 subjects were studied, with 22% (n=106) treated for recoarctation during the interstage period. Number of catheterizations per Norwood increased (P=0.005) over the interstage eras, with no significant change in the proportion of subjects with recoarctation (P=0.36). In parallel, there was a lower likelihood of hemodynamic compromise in subjects with recoarctation that was not statistically significant (P=0.06), with a significant difference in the proportion with ventricular dysfunction at intervention (P=0.002). Rates of technical success, procedural major adverse events, and transplant-free survival did not differ (P>0.05). Conclusions Periods with interstage monitoring were associated with increased referral for catheterization but also reduced likelihood of ventricular dysfunction (and a suggestion of lower likelihood of hemodynamic compromise) in subjects with recoarctation. Further study is needed to guide optimal interstage care of this vulnerable population.


Subject(s)
Hypoplastic Left Heart Syndrome , Norwood Procedures , Ventricular Dysfunction , Infant, Newborn , Humans , Infant , Treatment Outcome , Ventricular Dysfunction/etiology , Hemodynamics , Retrospective Studies , Risk Factors
11.
JACC Cardiovasc Interv ; 16(15): 1917-1928, 2023 08 14.
Article in English | MEDLINE | ID: mdl-37278682

ABSTRACT

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT). OBJECTIVES: One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients. METHODS: Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately. RESULTS: In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately. CONCLUSIONS: The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Ventricular Outflow Obstruction , Humans , Cardiac Catheterization , Prospective Studies , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Treatment Outcome , Ventricular Outflow Obstruction/etiology
12.
Ann Thorac Surg Short Rep ; 1(1): 40-45, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36909146

ABSTRACT

Background: Transcatheter edge-to-edge valve repair (TEER) is a complex procedure requiring delivery and alignment of the device to the target valve, which can be challenging in atypical or surgically palliated anatomy. We demonstrate application of virtual and physical simulation to plan optimal TEER access and catheter path in normal and congenitally abnormal cardiac anatomy. Methods: Three heart models were created from three-dimensional (3D) images and 3D printed, including two with congenital heart disease. TEER catheter course was simulated both virtually and physically using a commercial TEER system. Results: We demonstrate application of modeling in three patients, including two with congenital heart disease and a Fontan circulation. Access site and pathway to device delivery was simulated by members of a multidisciplinary valve team. Virtual and physical simulation were compared. Conclusions: Virtual and physical simulation of TEER using 3D printed heart models is feasible and may be beneficial for planning and simulation, particularly in patients with complex anatomy. Future work is required to demonstrate application in the clinical setting.

13.
Cardiovasc Res ; 119(1): 302-315, 2023 03 17.
Article in English | MEDLINE | ID: mdl-35020813

ABSTRACT

AIMS: Bioprosthetic heart valves (BHVs), made from glutaraldehyde-fixed heterograft materials, are subject to more rapid structural valve degeneration (SVD) in paediatric and young adult patients. Differences in blood biochemistries and propensity for disease accelerate SVD in these patients, which results in multiple re-operations with compounding risks. The goal of this study is to investigate the mechanisms of BHV biomaterial degeneration and present models for studying SVD in young patients and juvenile animal models. METHODS AND RESULTS: We studied SVD in clinical BHV explants from paediatric and young adult patients, juvenile sheep implantation model, rat subcutaneous implants, and an ex vivo serum incubation model. BHV biomaterials were analysed for calcification, collagen microstructure (alignment and crimp), and crosslinking density. Serum markers of calcification and tissue crosslinking were compared between young and adult subjects. We demonstrated that immature subjects were more susceptible to calcification, microstructural changes, and advanced glycation end products formation. In vivo and ex vivo studies comparing immature and mature subjects mirrored SVD in clinical observations. The interaction between host serum and BHV biomaterials leads to significant structural and biochemical changes which impact their functions. CONCLUSIONS: There is an increased risk for accelerated SVD in younger subjects, both experimental animals and patients. Increased calcification, altered collagen microstructure with loss of alignment and increased crimp periods, and increased crosslinking are three main characteristics in BHV explants from young subjects leading to SVD. Together, our studies establish a basis for assessing the increased susceptibility of BHV biomaterials to accelerated SVD in young patients.


Subject(s)
Bioprosthesis , Calcinosis , Heart Valve Prosthesis , Animals , Rats , Sheep , Heart Valves , Biocompatible Materials , Collagen
15.
World J Pediatr Congenit Heart Surg ; 13(6): 737-744, 2022 11.
Article in English | MEDLINE | ID: mdl-36300263

ABSTRACT

BACKGROUND: The Fontan circulation challenges the lymphatic system. Increasing production of lymphatic fluid and impeding lymphatic return, increased venous pressure may cause lymphatic dilatation and decrease lymphatic contractility. In-vitro studies have reported a lymphatic diameter-tension curve, with increasing passive stretch affecting the intrinsic contractile properties of each thoracic duct segment. We aimed to describe thoracic duct occlusion pressure and asses if thoracic duct dilation impairs contractility in individuals with a Fontan circulation and lymphatic failure. METHODS: Central venous pressure and thoracic duct measurements were retrospectively collected from 31 individuals with a Fontan circulation. Thoracic duct occlusion pressure was assessed during a period of external manual compression and used as an indicator of lymphatic vessel contractility. Measurements of pressure were correlated with measurements of the thoracic duct diameter in images obtained by dynamic contrast-enhanced MR lymphangiography. RESULTS: The average central venous pressure and average pressure of the thoracic duct were 17 mm Hg. During manual occlusion, the thoracic duct pressure significantly increased to 32 mm Hg. The average thoracic duct diameter was 3.3 mm. Thoracic duct diameter correlated closely with the central venous pressure. The rise in pressure following manual occlusion showed an inverse correlation with the diameter of the thoracic duct. CONCLUSION: Higher central venous pressures are associated with increasing diameters of the thoracic duct. When challenged by manual occlusion, dilated thoracic ducts display a decreased ability to increase pressure. Dilatation and a resulting decreased contractility may partly explain the challenged lymphatic system in individuals with a Fontan circulation.


Subject(s)
Lymphatic Vessels , Thoracic Duct , Humans , Dilatation , Retrospective Studies , Lymphatic System , Lymphatic Vessels/diagnostic imaging , Dilatation, Pathologic
17.
Circ Cardiovasc Interv ; 15(7): e011733, 2022 07.
Article in English | MEDLINE | ID: mdl-35708032

ABSTRACT

BACKGROUND: Lymphatic embolization therapy has proven effective for Fontan failure from plastic bronchitis or protein-losing enteropathy but not when multiple lymphatic compartments are involved; furthermore, embolization does not alter the underlying pathophysiology of lymphatic dysfunction. A technique for transcatheter thoracic duct decompression (TDD), rerouting the thoracic duct to the pulmonary venous atrium to treat multicompartment lymphatic failure is described and early outcomes presented. METHODS: Initially covered stents were used to channel the innominate vein flow inside of the cavopulmonary pathway into the pulmonary venous atrium. A modified approach was developed where covered stents redirected innominate vein directly to the left atrium via an extravascular course. Baseline and follow-up data on all patients undergoing TDD were reviewed. RESULTS: Twelve patients underwent TDD between March 2018 and February 2021 at a median age of 12 (range: 2-22) years. Lymphatic failure occurred in median of 3 compartments per patient (protein-losing enteropathy, ascites, pleural effusions, plastic bronchitis); 10 patients had lymphatic embolizations before TDD. TDD method was intra-Fontan tunnel in 4, direct approach in 7, and other in 1. There were no major procedural complications; 6 patients underwent subsequent procedures, most commonly to treat endoleaks. Lymphatic failure resolved in 6 patients, improved in 2, and was unchanged in 4 at 6 (range: 1-20) months follow-up. One patient died after TDD from Fontan failure. CONCLUSIONS: TDD is a promising new treatment for the failing Fontan physiology from multicompartment lymphatic failure. Additional work is needed to refine the technique and define optimal candidates.


Subject(s)
Bronchitis , Fontan Procedure , Heart Defects, Congenital , Protein-Losing Enteropathies , Adolescent , Adult , Bronchitis/etiology , Bronchitis/therapy , Child , Child, Preschool , Decompression/adverse effects , Fontan Procedure/adverse effects , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Humans , Plastics , Postoperative Complications/etiology , Protein-Losing Enteropathies/diagnosis , Protein-Losing Enteropathies/etiology , Protein-Losing Enteropathies/therapy , Thoracic Duct/diagnostic imaging , Thoracic Duct/surgery , Treatment Outcome , Young Adult
18.
World J Pediatr Congenit Heart Surg ; 13(2): 203-207, 2022 03.
Article in English | MEDLINE | ID: mdl-35238698

ABSTRACT

INTRODUCTION: While frequently performed in the adult population, percutaneous coronary artery stent angioplasty (CSA) in infants is rare. CSA in infants is challenging because of limited options in terms of appropriately sized (length and diameter) stents, concern about stenting vessels with significant growth potential and limited data regarding durability of benefit. We report a multicenter case series of infants who underwent CSA. METHODS: A multicenter, retrospective case series of infants who underwent percutaneous CSA to treat post-operative coronary artery stenoses was performed. RESULTS: Six infants from 3 institutions who underwent post-operative CSA were identified. The anatomic diagnoses were d-transposition of the great arteries in 3 cases, anomalous left coronary artery from the pulmonary artery in 2 and supravalvar aortic stenosis in 1. All infants were critically ill at the time of CSA. Diameters of coronary artery stents used ranged from 2.25 to 2.75 mm. There were no procedural complications. All stents were patent immediately after placement and the clinical condition improved or stabilized in all patients. Follow-up angiography was available for 3 patients at 4 to 16 months post-CSA, at which time 67% (2/3) remained patent. CONCLUSION: CSA is a feasible and effective therapy for critically ill infants with post-surgical coronary obstruction. Treatment appears to allow at least short-term reperfusion to facilitate recovery of ventricular function and potential development of collateral circulation when longer-term stent patency is not achieved. Longer-term stent patency and coronary artery health remain unanswered questions.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Stenosis , Transposition of Great Vessels , Adult , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/surgery , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Critical Illness , Follow-Up Studies , Humans , Infant , Retrospective Studies , Stents , Treatment Outcome
19.
Ann Thorac Surg ; 114(5): 1771-1777, 2022 11.
Article in English | MEDLINE | ID: mdl-35341786

ABSTRACT

BACKGROUND: We sought to characterize short- and long-term outcomes after superior cavopulmonary connection (SCPC) in children eligible for inclusion of antegrade pulmonary blood flow (APBF) in the SCPC circuit, exploring whether maintaining APBF was associated with outcomes. METHODS: This was a retrospective cohort study of patients with single-ventricle heart disease and APBF who underwent SCPC at our center between January 1, 2000, and September 30, 2017. Patients were divided into 2 groups: APBF eliminated (APBF-), and APBF maintained (APBF+) at the time of SCPC. RESULTS: Of 149 patients, 108 (72.5%) were in APBF- and 41 (27.5%) were in APBF+. Of those in APBF+, 5 (12.2%) subsequently had APBF eliminated after SCPC. Patients in APBF+ had a higher prevalence of chest tube duration >10 days and underwent more interventions during the post-SCPC hospitalization (1.9% vs 12%; P = .008 for both) but had shorter surgical support times at SCPC (P < .0001). There were no differences in post-SCPC intensive care unit or hospital length of stay. During the study period, 82 patients (76%) in APBF- and 22 patients (54%) in APBF+ underwent Fontan completion. Patients in APBF+ had a greater weight gain from SCPC to Fontan (6.7 [1.8-22] kg vs 8.15 [4.4-20.6] kg; P = .012) and a shorter hospital length of stay after Fontan (9 [4-107] days vs 7.5 [4-14] days; P = .044). CONCLUSIONS: Short-term morbidity associated with maintaining APBF at the time of SCPC is modest, but longer term outcomes suggest potential benefits in those in whom APBF can be successfully maintained.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Univentricular Heart , Child , Humans , Infant , Pulmonary Circulation/physiology , Heart Defects, Congenital/surgery , Retrospective Studies , Treatment Outcome , Heart Ventricles/surgery
20.
Am J Med Genet A ; 188(5): 1384-1395, 2022 05.
Article in English | MEDLINE | ID: mdl-35025139

ABSTRACT

Tetralogy of Fallot (ToF) can be associated with a wide range of extracardiac anomalies, with an underlying etiology identified in approximately 10% of cases. Individuals affected with Myhre syndrome due to recurrent SMAD4 mutations frequently have cardiovascular anomalies, including congenital heart defects. In addition to two patients in the literature with ToF, we describe five additional individuals with Myhre syndrome and classic ToF, ToF with pulmonary atresia and multiple aorto-pulmonary collaterals, and ToF with absent pulmonary valve. Aorta hypoplasia was documented in one patient and suspected in another two. In half of these individuals, postoperative cardiac dysfunction was thought to be more severe than classic postoperative ToF repair. There may be an increase in right ventricular pressure, and right ventricular dysfunction due to free pulmonic regurgitation. Noncardiac developmental abnormalities in our series and the literature, including corectopia, heterochromia iridis, and congenital miosis suggest an underlying defect of neural crest cell migration in Myhre syndrome. We advise clinicians that Myhre syndrome should be considered in the genetic evaluation of a child with ToF, short stature, unusual facial features, and developmental delay, as these children may be at risk for increased postoperative morbidity. Additional research is needed to investigate the hypothesis that postoperative hemodynamics in these patients may be consistent with restrictive myocardial physiology.


Subject(s)
Heart Defects, Congenital , Tetralogy of Fallot , Cryptorchidism , Facies , Growth Disorders , Hand Deformities, Congenital , Heart Defects, Congenital/complications , Humans , Intellectual Disability , Male , Neural Crest , Phenotype , Smad4 Protein/genetics , Tetralogy of Fallot/complications , Tetralogy of Fallot/genetics , Tetralogy of Fallot/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...