1.
Ophthalmic Physiol Opt ; 43(3): 368-376, 2023 05.
Article in English | MEDLINE | ID: mdl-36751114

ABSTRACT

PURPOSE: Topography of the in vivo anterior segment is of relevance in understanding its role in myopia and in the development of ocular surgical procedures. Using 3D magnetic resonance (MR) images of the human eye, regional variations in surface area (SA) and bulbosity of four anterior segment regions were investigated in association with refractive status (Rx), axial length (AL) and total ocular volume (OV). METHODS: T2-weighted ocular MR images from 43 adults aged 18-40 years (mean ± SD; 28.65 ± 6.20) comprising 20 non-myopes (≥-0.50) 0.57 ± 1.38 and 23 myopes (<-0.50) -6.37 ± 4.23 MSE (D) were collected. 2D representations of each quadrant (superior-temporal [ST], superior-nasal [SN], inferior-temporal [IT] and inferior-nasal [IN]) of the anterior section (3.5-9 mm) were fitted with second-order polynomials. Polynomials were integrated and rotated about the x-axis to generate SA; dividing the SA by 4 provided relative quadrantial SA. The x2 coefficient provides indices of bulbosity. OV was derived from the 3D MRI scans. Rx and AL were measured using cycloplegic autorefraction and the Zeiss IOLMaster, respectively. One- and two-way repeated-measures ANCOVAs tested differences in SA and bulbosity for Rx, gender, ethnicity and age. Pearson's correlation coefficient tested the relationship between MRI-derived metrics and biometry. RESULTS: Significant differences in SA were observed between quadrants (p < 0.001) with differences between ST versus IN, IN versus IT and SN versus IT. An interaction effect (p = 0.01) for Rx suggested smaller temporal (ST and IT) and larger nasal (SN and IN) SA in myopes. AL and myopic Rx were negative correlated (p < 0.05) with SA at IN, SN and IT. OV was significantly associated with SA at ST. Bulbosity showed no regional differences nor an effect of AL or Rx. CONCLUSION: Significant regional variation in SA exists across the anterior segment that is modulated by Rx and AL. It is unclear whether these structural characteristics are a precursor or consequence of myopia and may warrant investigation when developing biomechanical interventions.


Subject(s)
Myopia , Adult , Humans , Myopia/diagnosis , Myopia/pathology , Eye , Refraction, Ocular , Biometry
2.
Ophthalmic Physiol Opt ; 40(4): 472-481, 2020 07.
Article in English | MEDLINE | ID: mdl-32495401

ABSTRACT

PURPOSE: To measure regional variations in anterior scleral resistance (ASR) using a ballistic rebound tonometer (RBT) and examine whether the variations are significantly affected by ethnicity and refractive error (RE). METHODS: ASR was measured using a RBT (iCare TA01) following calibration against the biomechanical properties of agarose biogels. Eight scleral regions (nasal, temporal, superior, inferior, inferior-nasal, inferior-temporal, superior-nasal and superior-temporal) were measured at locations 4mm from the limbus. Subjects were 130 young adults comprising three ethnic groups whose RE distributions [MSE (D) ± S.D.] incorporated individuals categorised as without-myopia (NM; MSE ≥ -0.50) and with-myopia (WM; MSE < -0.50); British-White (BW): 26 NM + 0.52 ± 1.15D; 22 WM -3.83 ± 2.89D]; British-South-Asian (BSA): [9 NM + 0.49 ± 1.06D; 11 WM -5.07 ± 3.76D; Hong-Kong-Chinese (HKC): [11 NM + 0.39 ± 0.66D; 49 WM -4.46 ± 2.70D]. Biometric data were compiled using cycloplegic open-field autorefraction and the Zeiss IOLMaster. Two- and three-way repeated measures analysis of variances (anovas) tested regional differences for RBT values across both refractive status and ethnicity whilst stepwise forward multiple linear regression was used as an exploratory test. RESULTS: Significant regional variations in ASR were identified for the BW, BSA and HKC (p < 0.001) individuals; superior-temporal region showed the lowest levels of resistance whilst the inferior-nasal region the highest. Compared to the BW and BSA groups, the HKC subjects displayed a significant increase in mean resistance for each respective region (p < 0.001). With the exception of the inferior region, ethnicity was found to be the chief predictor for variation in the scleral RBT values for all other regions. Mean RE group differences were insignificant. CONCLUSIONS: The novel application of RBT to the anterior sclera confirm regional variation in ASR. Greater ASR amongst the HKC group than the BW and BSA individuals suggests that ethnic differences in anterior scleral biomechanics may exist.


Subject(s)
Biometry/methods , Myopia/physiopathology , Sclera/physiopathology , Tonometry, Ocular/methods , Adult , Female , Humans , Male , Manometry , Myopia/diagnosis , Sclera/diagnostic imaging , Tomography, Optical Coherence/methods , Young Adult
3.
Optom Vis Sci ; 95(4): 399-404, 2018 04.
Article in English | MEDLINE | ID: mdl-29554010

ABSTRACT

SIGNIFICANCE: Poor peripheral visual acuity in myopia may reflect, in part, photoreceptor misalignment with the exit pupil of the eye. We speculate that if such misalignment causes sufficient visual deprivation and/or disrupts retinal feedback processes, it may influence eye growth itself. PURPOSE: It is known that myopic eyes have a reduced peripheral resolution acuity relative to emmetropic eyes, though it remains unclear how mechanical stretching of the retina in myopia impacts on peripheral visual performance. Our aim was to determine how retinal stretching affects the properties of sampling units in peripheral vision. METHODS: Three-dimensional magnetic resonance imaging provided a depiction in vivo of ocular shape, allowing the inter-eye ratio of retinal image surface areas and the relative alignment of surfaces to be determined in our observer, who was unique in having severe myopia in the right eye (~21 D) but only modest myopia in the left (~3 D). Visual performance was assessed for the detection and direction discrimination of drifting sinusoids positioned 40° in the temporal retina. Applying the sampling theorem to our measures, we estimated the density and cut-off frequency of the underlying sampling units. RESULTS: The retinal image surface area of the right eye was 40% larger than that of the left and was rotated 8.9° anticlockwise relative to the left eye's image surface. In agreement with a linear stretch model of myopia, the sampling density of the right eye was reduced by approximately the same ratio as that predicted from the inter-eye MRI data, namely, 1.18. However, the cut-off frequency (cycles/mm) of the right eye was approximately half that of the left, a reduction that cannot be explained solely by a linear areal expansion of retinal sampling units. CONCLUSIONS: Poor peripheral acuity in severe myopia may be caused, at least in part, by receptoral misalignment with the exit pupil.


Subject(s)
Myopia/physiopathology , Refraction, Ocular/physiology , Retina/physiopathology , Visual Acuity/physiology , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Middle Aged , Myopia/diagnostic imaging , Psychometrics , Retina/diagnostic imaging , Retinoscopy
4.
Eye Contact Lens ; 44(4): 260-267, 2018 Jul.
Article in English | MEDLINE | ID: mdl-27763910

ABSTRACT

PURPOSE: To assess the relationship between short-term and long-term changes in power at different corneal locations relative to the change in central corneal power and the 2-year change in axial elongation relative to baseline in children fitted with orthokeratology contact lenses (OK). METHODS: Thirty-one white European subjects 6 to 12 years of age and with myopia -0.75 to -4.00 DS and astigmatism ≤1.00 DC were fitted with OK. Differences in refractive power 3 and 24 months post-OK in comparison with baseline and relative to the change in central corneal power were determined from corneal topography data in eight different corneal regions (i.e., N[nasal]1, N2, T[temporal]1, T2, I[inferior]1, I2, S[superior]1, S2), and correlated with OK-induced axial length changes at two years relative to baseline. RESULTS: After 2 years of OK lens wear, axial length increased by 0.48±0.18 mm (P<0.001), which corresponded to an increase of 1.94±0.74% ([2-years change in axial length/baseline axial length]×100). However, the change in axial elongation in comparison with baseline was not significantly correlated with changes in corneal power induced by OK relative to baseline for any of the corneal regions assessed (all P>0.05). CONCLUSION: The reduction in central corneal power and relative increase in paracentral and pericentral power induced by OK over 2 years were not significantly correlated with concurrent changes in axial length of white European children.


Subject(s)
Axial Length, Eye/physiology , Contact Lenses , Cornea/physiology , Myopia/physiopathology , Myopia/therapy , Orthokeratologic Procedures/methods , Analysis of Variance , Child , Corneal Topography , Female , Humans , Male , Refraction, Ocular , White People
5.
J Anat ; 231(3): 319-324, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28620965

ABSTRACT

Previous attempts at determining retinal surface area and surface area of the whole eye have been based upon mathematical calculations derived from retinal photographs, schematic eyes and retinal biopsies of donor eyes. 3-dimensional (3-D) ocular magnetic resonance imaging (MRI) allows a more direct measurement, it can be used to image the eye in vivo, and there is no risk of tissue shrinkage. The primary purpose of this study is to compare, using T2-weighted 3D MRI, retinal surface areas for superior-temporal (ST), inferior-temporal (IT), superior-nasal (SN) and inferior-nasal (IN) retinal quadrants. An ancillary aim is to examine whether inter-quadrant variations in area are concordant with reported inter-quadrant patterns of susceptibility to retinal breaks associated with posterior vitreous detachment (PVD). Seventy-three adult participants presenting without retinal pathology (mean age 26.25 ± 6.06 years) were scanned using a Siemens 3-Tesla MRI scanner to provide T2-weighted MR images that demarcate fluid-filled internal structures for the whole eye and provide high-contrast delineation of the vitreous-retina interface. Integrated MRI software generated total internal ocular surface area (TSA). The second nodal point was used to demarcate the origin of the peripheral retina in order to calculate total retinal surface area (RSA) and quadrant retinal surface areas (QRSA) for ST, IT, SN, and IN quadrants. Mean spherical error (MSE) was -2.50 ± 4.03D and mean axial length (AL) 24.51 ± 1.57 mm. Mean TSA and RSA for the RE were 2058 ± 189 and 1363 ± 160 mm2 , respectively. Repeated measures anova for QRSA data indicated a significant difference within-quadrants (P < 0.01) which, contrasted with ST (365 ± 43 mm2 ), was significant for IT (340 ± 40 mm2 P < 0.01), SN (337 ± 40 mm2 P < 0.01) and IN (321 ± 39 mm2 P < 0.01) quadrants. For all quadrants, QRSA was significantly correlated with AL (P < 0.01) and exhibited equivalent increases in retinal area/mm increase in AL. Although the differences between QRSAs are relatively small, there was evidence of concordance with reported inter-quadrant patterns of susceptibility to retinal breaks associated with PVD. The data allow AL to be converted to QRSAs, which will assist further work on inter-quadrant structural variation.


Subject(s)
Retina/diagnostic imaging , Adolescent , Adult , Female , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Young Adult
6.
Eye Contact Lens ; 43(6): 358-363, 2017 Nov.
Article in English | MEDLINE | ID: mdl-27341092

ABSTRACT

PURPOSE: To assess the correlation between changes in corneal aberrations and the 2-year change in axial length in children fitted with orthokeratology (OK) contact lenses. METHODS: Thirty-one subjects 6 to 12 years of age and with myopia -0.75 to -4.00DS and astigmatism ≤1.00DC were fitted with OK. Measurements of axial length and corneal topography were taken at regular intervals over a 2-year period. Corneal topography at baseline and after 3 and 24 months of OK lens wear was used to derive higher-order corneal aberrations (HOA) that were correlated with OK-induced axial length changes at 2 years. RESULTS: Significant changes in (Equation is included in full-text article.)root mean square (RMS) secondary astigmatism and fourth and total HOA were found with both 3 and 24 months of OK lens wear in comparison with baseline (all P<0.05). Additionally, significant changes in (Equation is included in full-text article.)and RMS tetrafoil were found at 3 months and in second-order RMS at 24 months of OK lens wear in comparison with baseline (all P<0.05). However, none of the changes in corneal aberrations were significantly correlated with the 2-year change in axial elongation (all P>0.05). Coma angle of orientation changed significantly pre-OK in comparison with 3 and 24 months post-OK as well as secondary astigmatism angle of orientation pre-OK in comparison with 24 months post-OK (all P<0.05). However, coma, trefoil, secondary astigmatism, and tetrafoil angles of orientation pre-OK or post-OK were not significantly correlated with the 2-year change in axial elongation (all P>0.05). DISCUSSION: Short-term and long-term OK lens wear induces significant changes in corneal aberrations that are not significantly correlated with changes in axial elongation after 2-years.


Subject(s)
Astigmatism/therapy , Axial Length, Eye/physiopathology , Contact Lenses, Hydrophilic , Corneal Wavefront Aberration/physiopathology , Myopia/therapy , Orthokeratologic Procedures/methods , Astigmatism/physiopathology , Child , Female , Humans , Male , Myopia/physiopathology
7.
Curr Eye Res ; 42(5): 713-720, 2017 05.
Article in English | MEDLINE | ID: mdl-27767354

ABSTRACT

PURPOSE: The primary outcome of this study is to compare the axial length growth of white European myopic children wearing orthokeratology contact lenses (OK) to a control group (CT) over a 7-year period. METHODS: Subjects 6-12 years of age with myopia -0.75 to -4.00DS and astigmatism ≤1.00DC were prospectively allocated OK or distance single-vision spectacles (SV) correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals over a 2-year period. Subjects were invited to return to the clinic approximately 5 years later (i.e., 7 years after the beginning of the study) for assessment of their ocular refractive and biometric components. The CT consisted of 4 SV and 12 subjects who switched from SV to soft contact lens wear after the initial 2 years of SV lens wear. Changes in axial length relative to baseline over a 7-year period were compared between groups. RESULTS: Fourteen and 16 subjects from the OK and CT groups, respectively, were examined 6.7 ± 0.5 years after the beginning of the study. Statistically significant changes in the axial length were found over time and between groups (both p < 0.001), but not for the time*group interaction (p = 0.125). The change in the axial length for the OK group was 22% (p = 0.328), 42% (p = 0.007), 40% (p = 0.020), 41% (p = 0.013), and 33% (p = 0.062) lower than the CT group following 6, 12, 18, 24, and 84 months of lens wear, respectively. CONCLUSION: A trend toward a reduction in the rate of axial elongation of the order of 33% was found in the OK group in comparison to the CT group following 7 years of lens wear.


Subject(s)
Axial Length, Eye/pathology , Contact Lenses, Hydrophilic , Myopia/therapy , Orthokeratologic Procedures/methods , Refraction, Ocular , Child , Corneal Topography , Disease Progression , Female , Follow-Up Studies , Humans , Male , Myopia/diagnosis , Myopia/physiopathology , Time Factors , Treatment Outcome
8.
Br J Ophthalmol ; 100(7): 882-890, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26802174

ABSTRACT

The aim of this review was to quantify the global variation in childhood myopia prevalence over time taking account of demographic and study design factors. A systematic review identified population-based surveys with estimates of childhood myopia prevalence published by February 2015. Multilevel binomial logistic regression of log odds of myopia was used to examine the association with age, gender, urban versus rural setting and survey year, among populations of different ethnic origins, adjusting for study design factors. 143 published articles (42 countries, 374 349 subjects aged 1-18 years, 74 847 myopia cases) were included. Increase in myopia prevalence with age varied by ethnicity. East Asians showed the highest prevalence, reaching 69% (95% credible intervals (CrI) 61% to 77%) at 15 years of age (86% among Singaporean-Chinese). Blacks in Africa had the lowest prevalence; 5.5% at 15 years (95% CrI 3% to 9%). Time trends in myopia prevalence over the last decade were small in whites, increased by 23% in East Asians, with a weaker increase among South Asians. Children from urban environments have 2.6 times the odds of myopia compared with those from rural environments. In whites and East Asians sex differences emerge at about 9 years of age; by late adolescence girls are twice as likely as boys to be myopic. Marked ethnic differences in age-specific prevalence of myopia exist. Rapid increases in myopia prevalence over time, particularly in East Asians, combined with a universally higher risk of myopia in urban settings, suggest that environmental factors play an important role in myopia development, which may offer scope for prevention.


Subject(s)
Ethnicity , Myopia , Rural Population , Child , Female , Global Health , Humans , Male , Myopia/ethnology , Myopia/etiology , Myopia/prevention & control , Prevalence , Surveys and Questionnaires , Time Factors
9.
Ophthalmic Physiol Opt ; 35(6): 622-7, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26497294

ABSTRACT

PURPOSE: The Shin-Nippon SRW-5000 is an open view autorefractor that superseded the Canon R-1 autorefractor in the mid-1990 s and has been used widely in optometry and vision science laboratories. It has been used to measure refractive error, accommodation responses both statically and dynamically, off-axis refractive error, and adapted to measure pupil size. This paper presents an overview of the original 2001 clinical evaluation of the SRW-5000 in adults (Mallen et al., Ophthal Physiol Opt 2001; 21: 101) and provides an update on the use and modification of the instrument since the original publication. RECENT FINDINGS: The SRW-5000 instrument, and the family of devices which followed, have shown excellent validity, repeatability, and utility in clinical and research settings. The instruments have also shown great potential for increased research functionality following a number of modifications. SUMMARY: The SRW-5000 and its derivatives have been, and continue to be, of significant importance in our drive to understand myopia progression, myopia control techniques, and oculomotor function in human vision.


Subject(s)
Optometry/instrumentation , Refraction, Ocular/physiology , Refractive Errors/diagnosis , Refractometry/instrumentation , Vision Screening/instrumentation , Accommodation, Ocular/physiology , Adult , Humans , Myopia/physiopathology , Optometry/methods , Refractive Errors/physiopathology , Reproducibility of Results , Vision Screening/methods
10.
Clin Exp Optom ; 98(6): 534-40, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26283026

ABSTRACT

BACKGROUND: The aim was to assess the potential association between entrance pupil location relative to the coaxially sighted corneal light reflex (CSCLR) and the progression of myopia in children fitted with orthokeratology (OK) contact lenses. Additionally, whether coma aberration induced by decentration of the entrance pupil centre relative to the CSCLR, as well as following OK treatment, is correlated with the progression of myopia, was also investigated. METHODS: Twenty-nine subjects aged six to 12 years and with myopia of -0.75 to -4.00 DS and astigmatism up to 1.00 DC were fitted with OK contact lenses. Measurements of axial length and corneal topography were taken at six-month intervals over a two-year period. Additionally, baseline and three-month topographic outputs were taken as representative of the pre- and post-orthokeratology treatment status. Pupil centration relative to the CSCLR and magnitude of associated corneal coma were derived from corneal topographic data at baseline and after three months of lens wear. RESULTS: The centre of the entrance pupil was located superio-temporally to the CSCLR both pre- (0.09 ± 0.14 and -0.10 ± 0.15 mm, respectively) and post-orthokeratology (0.12 ± 0.18 and -0.09 ± 0.15 mm, respectively) (p > 0.05). Entrance pupil location pre- and post-orthokeratology lens wear was not significantly associated with the two-year change in axial length (p > 0.05). Significantly greater coma was found at the entrance pupil centre compared with CSCLR both pre- and post-orthokeratology lens wear (both p < 0.05). A significant increase in vertical coma was found with OK lens wear compared to baseline (p < 0.001) but total root mean square (RMS) coma was not associated with the change in axial length (all p > 0.05). CONCLUSION: Entrance pupil location relative to the CSCLR was not significantly affected by either OK lens wear or an increase in axial length. Greater magnitude coma aberrations found at the entrance pupil centre in comparison to the CSCLR might be attributed to centration of orthokeratological treatments at the CSCLR.


Subject(s)
Blinking/physiology , Cornea/pathology , Myopia/therapy , Orthokeratologic Procedures/methods , Pupil/physiology , Refraction, Ocular/physiology , Axial Length, Eye , Child , Contact Lenses , Corneal Topography , Disease Progression , Female , Follow-Up Studies , Humans , Male , Myopia/pathology , Myopia/physiopathology
11.
PLoS One ; 10(7): e0132902, 2015.
Article in English | MEDLINE | ID: mdl-26218188

ABSTRACT

Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-to-posterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- and inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46 µm. Meridian SN was the thinnest (662±57 µm) and I the thickest (806±60 µm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4 mm. AST measurements at 1mm (682±48 µm) were the thinnest and at 6mm (818±49 µm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention.


Subject(s)
Sclera , Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/methods , Adolescent , Adult , Cross-Sectional Studies , Female , Humans , Male
12.
Br J Ophthalmol ; 98(12): 1697-701, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24985726

ABSTRACT

BACKGROUND/AIMS: To determine which biometric parameters provide optimum predictive power for ocular volume. METHODS: Sixty-seven adult subjects were scanned with a Siemens 3-T MRI scanner. Mean spherical error (MSE) (D) was measured with a Shin-Nippon autorefractor and a Zeiss IOLMaster used to measure (mm) axial length (AL), anterior chamber depth (ACD) and corneal radius (CR). Total ocular volume (TOV) was calculated from T2-weighted MRIs (voxel size 1.0 mm(3)) using an automatic voxel counting and shading algorithm. Each MR slice was subsequently edited manually in the axial, sagittal and coronal plane, the latter enabling location of the posterior pole of the crystalline lens and partitioning of TOV into anterior (AV) and posterior volume (PV) regions. RESULTS: Mean values (±SD) for MSE (D), AL (mm), ACD (mm) and CR (mm) were -2.62±3.83, 24.51±1.47, 3.55±0.34 and 7.75±0.28, respectively. Mean values (±SD) for TOV, AV and PV (mm(3)) were 8168.21±1141.86, 1099.40±139.24 and 7068.82±1134.05, respectively. TOV showed significant correlation with MSE, AL, PV (all p<0.001), CR (p=0.043) and ACD (p=0.024). Bar CR, the correlations were shown to be wholly attributable to variation in PV. Multiple linear regression indicated that the combination of AL and CR provided optimum R(2) values of 79.4% for TOV. CONCLUSION: Clinically useful estimations of ocular volume can be obtained from measurement of AL and CR.


Subject(s)
Axial Length, Eye/anatomy & histology , Eye/anatomy & histology , Magnetic Resonance Imaging , Adolescent , Adult , Anterior Chamber/anatomy & histology , Biometry , Cornea/anatomy & histology , Female , Humans , Interferometry , Male , Organ Size , Refraction, Ocular/physiology , Young Adult
13.
Eye Contact Lens ; 40(2): 84-90, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24508773

ABSTRACT

OBJECTIVE: To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years. METHODS: Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear. RESULTS: A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06). CONCLUSIONS: The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.


Subject(s)
Astigmatism/therapy , Myopia/therapy , Orthokeratologic Procedures , Anterior Chamber/pathology , Astigmatism/pathology , Astigmatism/physiopathology , Axial Length, Eye/pathology , Biometry , Child , Corneal Topography , Female , Humans , Male , Myopia/pathology , Myopia/physiopathology , Refraction, Ocular/physiology
14.
Invest Ophthalmol Vis Sci ; 54(12): 7240-51, 2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24130182

ABSTRACT

PURPOSE: To compare posterior vitreous chamber shape in myopia to that in emmetropia. METHODS: Both eyes of 55 adult subjects were studied, 27 with emmetropia (mean spherical error [MSE] ≥ -0.55; <+0.75 D; mean +0.09 ± 0.36 D) and 28 with myopia (MSE -5.87 ± 2.31 D). Cycloplegic refraction was measured with a Shin Nippon autorefractor and anterior chamber depth and axial length with a Zeiss IOLMaster. Posterior vitreous chamber shapes were determined from T2-weighted magnetic resonance imaging (3.0-T) using procedures previously reported by our laboratory. Three-dimensional surface model coordinates were assigned to nasal, temporal, superior, and inferior quadrants and plotted in two dimensions to illustrate the composite shape of respective quadrants posterior to the second nodal point. Spherical analogues of chamber shape were constructed to compare relative sphericity between refractive groups and quadrants. RESULTS: Differences in shape occurred in the region posterior to points of maximum globe width and were thus in general accord with an equatorial model of myopic expansion. Shape in emmetropia is categorized distinctly as that of an oblate ellipse and in myopia as an oblate ellipse of significantly less degree such that it approximates to a sphere. There was concordance between shape and retinotopic projection of respective quadrants into right, left, superior, and inferior visual fields. CONCLUSIONS: Prolate ellipse posterior chamber shapes were rarely found in myopia, and we propose that spherical shape in myopia may constitute a biomechanical limitation on further axial elongation. Synchronization of quadrant shapes with retinotopic projection suggests that binocular growth is coordinated by processes that operate beyond the optic chiasm.


Subject(s)
Emmetropia , Myopia/pathology , Vitreous Body/pathology , Adult , Analysis of Variance , Biometry , Female , Humans , Magnetic Resonance Imaging/methods , Male , Young Adult
15.
Optom Vis Sci ; 90(11): 1225-36, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24037063

ABSTRACT

PURPOSE: To examine which baseline measurements constitute predictive factors for axial length growth over 2 years in children wearing orthokeratology contact lenses (OK) and single-vision spectacles (SV). METHODS: Sixty-one children were prospectively assigned to wear either OK (n = 31) or SV (n = 30) for 2 years. The primary outcome measure (dependent variable) was axial length change at 2 years relative to baseline. Other measurements (independent variables) were age, age of myopia onset, gender, myopia progression 2 years before baseline and baseline myopia, anterior chamber depth, corneal power and shape (p value), and iris and pupil diameters as well as parental refraction. The contribution of all independent variables to the 2-year change in axial length was assessed using univariate and multivariate regression analyses. RESULTS: After univariate analyses, smaller increases in axial length were found in the OK group compared to the SV group in children who were older, had earlier onset of myopia, were female, had lower rate of myopia progression before baseline, had less myopia at baseline, had longer anterior chamber depth, had greater corneal power, had more prolate corneal shape, had larger iris diameter, had larger pupil sizes, and had lower levels of parental myopia (all p < 0.05). In multivariate analyses, older age and greater corneal power were associated with smaller increases in axial length in the OK group (both p < 0.05), whereas in SV wearers, smaller iris diameter was associated with smaller increases in axial length (p = 0.021). CONCLUSIONS: Orthokeratology is a successful treatment option in controlling axial elongation compared to SV in children of older age, had earlier onset of myopia, were female, had lower rate of myopia progression before baseline, had lower myopia at baseline, had longer anterior chamber depth, had greater corneal power, had more prolate corneal shape, had larger iris and pupil diameters, and had lower levels of parental myopia.


Subject(s)
Contact Lenses , Eyeglasses , Myopia/prevention & control , Orthokeratologic Procedures , Axial Length, Eye/physiopathology , Child , Cornea/physiopathology , Disease Progression , Female , Humans , Male , Myopia/physiopathology , Refraction, Ocular/physiology
16.
Ophthalmic Physiol Opt ; 33(3): 311-7, 2013 May.
Article in English | MEDLINE | ID: mdl-23662963

ABSTRACT

OBJECTIVE: To assess the magnitude of nearwork-induced transient myopia (NITM) under binocular viewing conditions separately in each eye of individuals with mild to moderate anisometropia to determine the relationship between NITM and their interocular refractive error. METHODS: Forty-three children and young adults with anisometropia [cycloplegic spherical equivalent (SE) difference >1.00 D] were tested (ages 9-28 years). NITM was measured with binocular viewing separately in each eye after binocularly performing a sustained near task (5 D) for 5 min incorporating a cognitive demand using an open-field, infrared autorefractor (Grand-Seiko, WAM-5500). Data were averaged over 10 s bins for 3 min in each eye. Initial NITM, its decay time (DT), and its decay area (DA) were determined. A-scan ultrasound ocular biometry was also performed to determine the axial length of each eye. RESULTS: The more myopic eye exhibited increased initial NITM, DT, and DA as compared to the less myopic eye (0.21 ± 0.16 D vs 0.15 ± 0.13 D, p = 0.026; 108.4 ± 64.3 secs vs 87.0 ± 65.2 secs, p = 0.04; and 17.6 ± 18.7 D*secs vs 12.3 ± 15.7 D*secs, p = 0.064), respectively. The difference in DA and the difference in SE between the more versus less myopic eye were significantly correlated (r = 0.31, p = 0.044). Furthermore, 63% (27/43), 56% (24/43), and 70% (30/43) of the more myopic eyes exhibited increased initial NITM, longer DT, and larger DA, respectively, than found in the less myopic eye. CONCLUSIONS: In approximately two-thirds of the anisometropic individuals, the initial NITM and its decay area were significantly increased in the more myopic eye as compared to the less myopic eye. NITM may play an important role in the development of interocular differences in myopia, although a causal relationship is yet to be established. Furthermore, the findings have potentially important implications regarding accommodative control and interocular accommodative responsitivity in anisometropia, in particular for anisomyopia.


Subject(s)
Anisometropia/physiopathology , Myopia/physiopathology , Accommodation, Ocular/physiology , Adolescent , Adult , Analysis of Variance , Child , Female , Humans , Male , Photic Stimulation/methods , Refraction, Ocular/physiology , Young Adult
17.
Ophthalmic Physiol Opt ; 33(3): 294-304, 2013 May.
Article in English | MEDLINE | ID: mdl-23452002

ABSTRACT

PURPOSE: Anterior segment optical coherent tomography (AS-OCT) is used to further examine previous reports that ciliary muscle thickness (CMT) is increased in myopic eyes. With reference to temporal and nasal CMT, interrelationships between biometric and morphological characteristics of anterior and posterior segments are analysed for British-White and British-South-Asian adults with and without myopia. METHODS: Data are presented for the right eyes of 62 subjects (British-White n = 39, British-South-Asian n = 23, aged 18-40 years) with a range of refractive error (mean spherical error (MSE (D)) -1.74 ± 3.26; range -10.06 to +4.38) and separated into myopes (MSE (D) <-0.50, range -10.06 to -0.56; n = 30) and non-myopes (MSE (D) ≥-0.50, -0.50 to +4.38; n = 32). Temporal and nasal ciliary muscle cross-sections were imaged using a Visante AS-OCT. Using Visante software, manual measures of nasal and temporal CMT (NCMT and TCMT respectively) were taken in successive posterior 1 mm steps from the scleral spur over a 3 mm distance (designated NCMT1, TCMT1 et seq). Measures of axial length and anterior chamber depth were taken with an IOLMaster biometer. MSE and corneal curvature (CC) measurements were taken with a Shin-Nippon auto-refractor. Magnetic resonance imaging was used to determine total ocular volume (OV) for 31 of the original subject group. Statistical comparisons and analyses were made using mixed repeated measures anovas, Pearson's correlation coefficient and stepwise forward multiple linear regression. RESULTS: MSE was significantly associated with CMT, with thicker CMT2 and CMT3 being found in the myopic eyes (p = 0.002). In non-myopic eyes TCMT1, TCMT2, NCMT1 and NCMT2 correlated significantly with MSE, AL and OV (p < 0.05). In contrast, myopic eyes failed generally to exhibit a significant correlation between CMT, MSE and axial length but notably retained a significant correlation between OV, TCMT2, TCMT3, NCMT2 and NCMT3 (p < 0.05). OV was found to be a significantly better predictor of TCMT2 and TCMT3 than AL by approximately a factor of two (p < 0.001). Anterior chamber depth was significantly associated with both temporal and nasal CMT2 and CMT3; TCMT1 correlated positively with CC. Ethnicity had no significant effect on differences in CMT. CONCLUSIONS: Increased CMT is associated with myopia. We speculate that the lack of correlation in myopic subjects between CMT and axial length, but not between CMT and OV, is evidence that disrupted feedback between the fovea and ciliary apparatus occurs in myopia development.


Subject(s)
Ciliary Body/pathology , Muscle, Smooth/pathology , Myopia/pathology , Adolescent , Adult , Analysis of Variance , Anterior Chamber/pathology , Asian People , Axial Length, Eye/pathology , Biometry , Female , Humans , Male , Myopia/ethnology , Reproducibility of Results , Tomography, Optical Coherence/methods , White People , Young Adult
18.
Eye Contact Lens ; 39(2): 153-7, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23392299

ABSTRACT

PURPOSE: To compare vision-related quality-of-life measures between children wearing orthokeratology (OK) contact lenses and distance single-vision (SV) spectacles. METHODS: Subjects 6 to 12 years of age and with myopia of -0.75 to -4.00 diopters and astigmatism less than or equal to 1.00 diopters were prospectively assigned OK contact lens or SV spectacle correction. A pediatric refractive error profile questionnaire was administered at 12- and 24-month intervals to evaluate children's perceptions in terms of overall vision, near vision, far distance vision, symptoms, appearance, satisfaction, activities, academic performance, handling, and peer perceptions. The mean score of all items was calculated as the overall score. Additionally, parents/guardians were asked to rate their child's mode of visual correction and their intention to continue treatment after study completion. RESULTS: Thirty-one children were fitted with OK contact lenses and 30 with SV spectacles. Children wearing OK contact lenses rated overall vision, far distance vision, symptoms, appearance, satisfaction, activities, academic performance, handling, peer perceptions, and the overall score significantly better than children wearing SV spectacles (all P<0.05). Near vision and handling were, respectively, rated better (P<0.001) and similar (P=0.44) for SV spectacles in comparison to OK contact lenses. No significant differences were found between 12 and 24 months for any of the subjective ratings assessed (all P>0.05). Parents/guardians of children wearing OK contact lenses rated visual correction method and intention to continue treatment higher than parents of children wearing SV spectacles (P≤0.01). CONCLUSION: The results indicate that the significant improvement in vision-related quality of life and acceptability with OK contact lenses is an incentive to engage in its use for the control of myopia in children.


Subject(s)
Contact Lenses , Eyeglasses , Myopia/rehabilitation , Orthokeratologic Procedures/methods , Quality of Life , Visual Acuity/physiology , Child , Female , Humans , Male , Myopia/physiopathology , Prospective Studies , Refraction, Ocular/physiology , Spain , Surveys and Questionnaires
19.
Optom Vis Sci ; 89(8): 1133-9, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22773180

ABSTRACT

PURPOSE: To assess the relative clinical success of orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) in children in terms of incidences of adverse events and discontinuations over a 2-year period. METHODS: Sixty-one subjects 6 to 12 years of age with myopia of - 0.75 to - 4.00DS and astigmatism ≤1.00DC were prospectively allocated OK or SV correction. Subjects were followed at 6-month intervals and advised to report to the clinic immediately should adverse events occur. Adverse events were categorized into serious, significant, and non-significant. Discontinuation was defined as cessation of lens wear for the remainder of the study. RESULTS: Thirty-one children were corrected with OK and 30 with SV. A higher incidence of adverse events was found with OK compared with SV (p < 0.001). Nine OK subjects experienced 16 adverse events (7 significant and 9 non-significant). No adverse events were found in the SV group. Most adverse events were found between 6 and 12 months of lens wear, with 11 solely attributable to OK wear. Significantly more discontinuations were found with SV in comparison with OK (p < 0.05). CONCLUSIONS: The relatively low incidence of adverse events and discontinuations with OK is conducive for the correction of myopia in children with OK contact lenses.


Subject(s)
Astigmatism/therapy , Contact Lenses, Hydrophilic/adverse effects , Corneal Diseases/etiology , Eyeglasses/adverse effects , Myopia/therapy , Orthokeratologic Procedures/adverse effects , Astigmatism/physiopathology , Child , Corneal Diseases/epidemiology , Follow-Up Studies , Humans , Incidence , Myopia/physiopathology , Orthokeratologic Procedures/methods , Prospective Studies , Refraction, Ocular , Risk Factors , Spain/epidemiology
20.
Invest Ophthalmol Vis Sci ; 53(8): 5060-5, 2012 Jul 31.
Article in English | MEDLINE | ID: mdl-22729437

ABSTRACT

PURPOSE: To compare axial length growth between white children with myopia wearing orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) over a 2-year period. METHODS: Subjects 6 to 12 years of age with myopia -0.75 to -4.00 diopters of sphere (DS) and astigmatism ≤1.00 diopters of cylinder (DC) were prospectively allocated OK or SV correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals. RESULTS: Thirty-one children were fitted with OK and 30 with SV. Following 24 months, axial length increased significantly over time for both the OK group (0.47 mm) and SV group (0.69 mm; P < 0.001), with a significant interaction between time and group (P = 0.05) reflecting a greater increase in the SV group. Significant differences in refraction were found over time, between groups and for the interaction between time and group for spherical (all P < 0.001) but not cylindrical components of refraction (all P > 0.05). Significantly greater corneal flattening was evident in the OK group for the flatter and steeper corneal powers and for corneal shape factor (all P ≤ 0.05). CONCLUSIONS: Orthokeratology contact lens wear reduces axial elongation in comparison to distance single-vision spectacles in children.


Subject(s)
Myopia/therapy , Orthokeratologic Procedures/methods , Axial Length, Eye/pathology , Biometry , Child , Contact Lenses, Extended-Wear , Corneal Topography , Female , Humans , Male , Myopia/pathology , Myopia/physiopathology , Prospective Studies , Refraction, Ocular/physiology , Spain