Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Article in English | MEDLINE | ID: mdl-38727642

ABSTRACT

BACKGROUND: Carotid artery stenting (CAS) has become a cornerstone of carotid revascularization for stroke prevention. Despite the advantages of CAS, large-scale randomized trials involving prior (single-layer) generation of carotid stents demonstrated its higher risk of periprocedural cerebrovascular events compared to carotid endarterectomy (CEA). Dual-layer mesh-covered stents (DLSs) showed promising results in terms of 30-day embolic events. This study aims to evaluate 30-day clinical efficacy of DLS against a closed-cell single-layer stent, based on large-volume data. METHODS: The study center is part of the Italian National Outcomes Evaluation Program (PNE). CAS procedures performed between November 2017 and September 2023 were retrospectively analyzed. Our primary endpoint was 30-day survival free of death, stroke, and myocardial infarction (MI). Periprocedural stroke rate, technical success and restenosis rate of CAS procedures performed with DLSs and first-generation stents (FGSs) were also evaluated. RESULTS: Over a total of 1101 CAS procedures (55 men; 745 males; mean age of 79±7.8 years), 80.2% were treated with DLS and 48.6% were symptomatic. The cumulative stroke-, MI- and death-free 30-day survival was 98.9%, Technical success was achieved in 98.9% of cases. The DLS group showed significantly lower 30-day death, stroke and death+stroke and periprocedural minor stroke rates compared to FGS group (P=0.04; P=0.04; P=0.003 and P=0.0002, respectively). CONCLUSIONS: The use of DLS in patients undergoing CAS in our large-volume center showed a high technical success rate and minimal cerebral embolic complications by 30 days. High volumes and an experienced interventional team may contribute to these favorable outcomes.

2.
J Cardiovasc Surg (Torino) ; 64(6): 608-614, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38015552

ABSTRACT

BACKGROUND: This study aims to assess the role and safety of post-dilatation in protected carotid artery stenting (PCAS) using the new MicroNet-covered 2nd-generation stent assessed by cone beam CT scans. METHODS: From March 2020 to March 2022, patients were enrolled in the study according to CT angiography results based on the following criteria: Evidence of 70% to 99% carotid stenosis in asymptomatic patients and 50% to 99% in symptomatic patients, per the NASCET index. Using a FilterWire EZ™ (Boston Scientific, Natick, MA, USA) embolic protection system (EPS), MicroNet-covered stent PCAS was performed by two interventional radiologists with at least 8 years of experience in endovascular intervention. Each patient underwent post-dilatation following stent placement. Finally, a third radiologist (not participating in the interventional procedures) evaluated the cone beam CT scans and calculated residual stenosis. Major and minor complications were recorded in the 30 days following the procedure. RESULTS: A total of 192 patients (121 male, mean age 73±10 years) were included in the study, and all patients received post-dilatation following stent implantation. Technical successes were achieved in all procedures. Adverse events noted in this study were limited to periprocedural transient ischemic attacks that occurred in three out of 192 patients (1.6%) and showed a swift complete recovery. The post-dilatation balloon diameters used in the study were: 5.0 mm (30.3%), 5.5 mm (39.3%) and 6 mm (30.3%). Optimized postdilatation resulted in a significant increase in the final luminal area. Similar improvements were observed in all subtypes of plaque. CONCLUSIONS: Post-dilatation in protected CAS is safe and induces a significant improvement in the cross-sectional area regardless of the stenotic plaque.


Subject(s)
Carotid Stenosis , Stroke , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/therapy , Carotid Stenosis/complications , Dilatation/adverse effects , Stents/adverse effects , Stroke/etiology , Computed Tomography Angiography/adverse effects , Treatment Outcome , Carotid Arteries , Cone-Beam Computed Tomography
3.
J Endovasc Ther ; 30(1): 18-24, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35114851

ABSTRACT

PURPOSE: Carotid revascularization can be associated with modifications of the vascular geometry, which may lead to complications. The changes on the vessel angulation before and after a carotid WallStent (WS) implantation are compared against 2 new dual-layer devices, CGuard (CG) and RoadSaver (RS). MATERIALS AND METHODS: The study prospectively recruited 217 consecutive patients (112 GC, 73 WS, and 32 RS, respectively). Angiography projections were explored and the one having a higher arterial angle was selected as a basal view. After stent implantation, a stent control angiography was performed selecting the projection having the maximal angle. The same procedure is followed in all the 3 stent types to guarantee comparable conditions. The angulation changes on the stented segments were quantified from both angiographies. The statistical analysis quantitatively compared the pre-and post-angles for the 3 stent types. The results are qualitatively illustrated using boxplots. Finally, the relation between pre- and post-angles measurements is analyzed using linear regression. RESULTS: For CG, no statistical difference in the axial vessel geometry between the basal and postprocedural angles was found. For WS and RS, statistical difference was found between pre- and post-angles. The regression analysis shows that CG induces lower changes from the original curvature with respect to WS and RS. CONCLUSION: Based on our results, CG determines minor changes over the basal morphology than WS and RS stents. Hence, CG respects better the native vessel anatomy than the other stents.Level of Evidence: Level 4, Case Series.


Subject(s)
Endovascular Procedures , Stents , Humans , Treatment Outcome , Endovascular Procedures/adverse effects
4.
Radiol Med ; 124(12): 1212-1219, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31473930

ABSTRACT

OBJECTIVE: To evaluate the prognostic value of sequential dual-phase CBCT (DP-CBCT) imaging performed during degradable starch microsphere TACE (DSM-TACE) session in predicting the HCC's response to treatment, evaluate with modify response evaluation criteria in solid tumours (mRECIST) at 1-month multi-detector CT (MDCT) follow-up. MATERIALS AND METHODS: Between January and May 2018, 24 patients (68.5 ± 8.5 year [45-85]) with HCC lesions (n = 96 [average 4/patient]) were prospectively enrolled. Imaging assessment included: pre-procedural MDCT, intra-procedural DP-CBCT performed before first and second DSM-TACEs and 1-month follow-up MDCT. Lesions' attenuation/pseudo-attenuation was defined as average value measured on ROIs (HU for MDCT; arbitrary unit called HU* for CBCT). Lesions' attenuation modification was correlated with the post-procedural mRECIST criteria at 1-month MDCT. RESULTS: Eighty-two DSM-TACEs were performed. Lesion's attenuation values were: pre-procedural MDCT arterial phase (AP) 107.00 HU (CI 95% 100.00-115.49), venous phase (VP) 85.00 HU (CI 95% 81.13-91.74); and lesion's pseudo-attenuation were: first CBCT-AP 305.00 HU* (CI 95% 259.77-354.04), CBCT-VP 155.00 HU* (CI 95% 135.00-163.34). For second CBCT were: -AP 210.00 HU* (CI 95% 179.47-228.58), -VP 141.00 HU* (CI 95% 125.47-158.11); and for post-procedural MDCT were: -AP 95.00 HU (CI 95% 81.35-102.00), -VP 83.00 HU (CI 95% 78.00-88.00). ROC curve analysis showed that a higher difference pseudo-attenuation between first and second DP-CBCTs is related to treatment response. The optimal cut-off value of the difference between first and second CBCT-APs to predict complete response, objective response (complete + partial response) and overall disease control (objective response + stable disease) were > 206 HU* (sensitivity 80.0%, specificity 81.7%), > 72 HU* (sensitivity 79.5%, specificity 83.0%) and > - 7 HU* (sensitivity 91.6%, specificity 65.4%), respectively. CONCLUSIONS: DP-CBCT can predict intra-procedurally, by assessing lesion pseudo-attenuation modification, the DSM-TACE 1-month treatment outcome.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic/methods , Cone-Beam Computed Tomography/methods , Liver Neoplasms , Starch/therapeutic use , Aged , Aged, 80 and over , Antibiotics, Antineoplastic/administration & dosage , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/therapy , Epirubicin/administration & dosage , Female , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Male , Microspheres , Middle Aged , Prognosis , Prospective Studies , ROC Curve , Radiography, Interventional/methods , Response Evaluation Criteria in Solid Tumors , Sensitivity and Specificity , Statistics, Nonparametric , Time Factors , Treatment Outcome
5.
Ann Vasc Surg ; 44: 415.e1-415.e5, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28483617

ABSTRACT

Aneurysmal degeneration of distal landing zones after endovascular aneurysm repair (EVAR) can be a potential cause of late failure of this technique. Aneurysmal degeneration of common iliac arteries increases the risk of rupture of the iliac aneurysm itself as well as of the abdominal aortic aneurysm owing to aneurysm's reperfusion as a type Ib endoleak. Reoperation consists in plugging and covering the internal iliac artery (IIA), by extension into the external iliac artery, or preservation of antegrade flow in IIA by iliac branch devices (IBDs) or sandwich technique. The management of common iliac aneurysms after EVAR with the purpose of preserving antegrade flow into IIA generally requires a brachial or axillary access. However, this approach may be theoretically associated with local or systemic complications. We report a case of IBD implantation after EVAR, using a steerable sheath for IIA bridging stent deployment via contralateral femoral approach.


Subject(s)
Aortic Aneurysm/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Catheterization, Peripheral/methods , Endovascular Procedures/instrumentation , Femoral Artery , Iliac Aneurysm/surgery , Stents , Vascular Access Devices , Aged , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Femoral Artery/diagnostic imaging , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/etiology , Male , Prosthesis Design , Punctures , Recurrence , Reoperation , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...