Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 49(2): 540-6, 2009 Feb 20.
Article in English | MEDLINE | ID: mdl-19124213

ABSTRACT

Cyclosporin A (CyA) is a cornerstone immunosuppressant for the prophylaxis against allograft rejection after organ transplantation. The most widely prescribed CyA formulation is Neoral soft gelatine capsules (Novartis Pharmaceuticals, Basel, Switzerland). After Novartis patent expiration, several generic formulations have been developed. In this paper, a simple and reliable HPLC method was developed and validated for the evaluation of four CyA degradation products (ID-005-95, CyH, IsoCyH and IsoCyA) and two related compounds (CyB and CyG) aimed for the quality control of Neoral capsules and its generic formulations. In a second step, the validated method was then compared to the USP assay method for capsules, where some of the mentioned impurities were not adequately resolved from the CyA peak. Isocratic elution at a flow rate of 1.0mLmin(-1) was employed on a Lichrospher RP-18 (4mmx250mm; 5microm) analytical column maintained at 75 degrees C with a tetrahydrofuran:phosphoric acid (0.05M) (44:56, v/v) as mobile phase. The chromatograms were recorded using a Hewlett Packard 1100 chromatographic system. The UV detection wavelength was performed at 220nm and 10microL of sample was injected. The developed method was validated in terms of selectivity, linearity, precision, accuracy, limit of detection and limit of quantitation. The validate method was successfully applied to commercial capsules, Neoral and generic versions. Therefore, the proposed method is suitable for the simultaneous determination of CyA as well as its major impurities.


Subject(s)
Cyclosporine/chemistry , Drug Contamination/prevention & control , Drugs, Generic/chemistry , Immunosuppressive Agents/chemistry , Calibration , Capsules , Chromatography, High Pressure Liquid/instrumentation , Chromatography, High Pressure Liquid/methods , Molecular Structure , Quality Control , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet
2.
Biomed Chromatogr ; 6(1): 20-3, 1992.
Article in English | MEDLINE | ID: mdl-1600370

ABSTRACT

A rapid, specific and reliable gas chromatographic assay procedure for Nifedipine in plasma has been developed. With a single-step solvent extraction, and electron capture detection, the method is sensitive to 0.5 ng/mL of plasma and the standard curve is linear from 0.5 to 500 ng/mL. Samples are protected from light to prevent formation of photodecomposition products. The method has been used to monitor drug concentrations in patients receiving therapeutic doses.


Subject(s)
Nifedipine/blood , Chromatography, Gas , Humans , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...