Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Environ Manage ; 158: 40-7, 2015 Aug 01.
Article in English | MEDLINE | ID: mdl-25950836

ABSTRACT

Restricted by federal regulations and limited remediation options, buildings contaminated with paint laden with polychlorinated biphenyls (PCBs) have high costs associated with the disposal of hazardous materials. As opposed to current remediation methods which are often destructive and a risk to the surrounding environment, this study suggests a non-metal treatment system (NMTS) and a bimetallic treatment system (BTS) as versatile remediation options for painted industrial structures including concrete buildings, and metal machine parts. In this field study, four areas of a discontinued Department of Defense site were treated and monitored over 3 weeks. PCB levels in paint and treatment system samples were analyzed through gas chromatography/electron capture detection (GC-ECD). PCB concentrations were reduced by 95 percent on painted concrete and by 60-97 percent on painted metal with the majority of the PCB removal occurring within the first week of application. Post treatment laboratory studies including the utilization of an activated metal treatment system (AMTS) further degraded PCBs in BTS and NMTS by up to 82 percent and 99 percent, respectively, indicating that a two-step remediation option is viable. These findings demonstrate that the NMTS and BTS can be an effective, nondestructive, remediation process for large painted structures, allowing for the reuse or sale of remediated materials that otherwise may have been disposed.


Subject(s)
Environmental Pollutants/chemistry , Environmental Restoration and Remediation , Paint , Polychlorinated Biphenyls/chemistry , Construction Materials , Humans , Military Personnel , United States
2.
J Environ Health Sci Eng ; 12(1): 57, 2014 Mar 06.
Article in English | MEDLINE | ID: mdl-24602329

ABSTRACT

BACKGROUND: Paint laden with polychlorinated biphenyls (PCBs) often acts as a point source for environmental contamination. It is advantageous to address contaminated paint before the PCBs transport to surrounding media; however, current disposal methods of painted material introduce a variety of complications. Previous work demonstrates that PCBs can be broken down at ambient temperatures and pressures through a degradation process involving magnesium metal and acidified ethanol. This report is an extension of that work by describing the development of a delivery system for said reaction in preparation for a field test. Two treatment options including the Activated Metal Treatment System (AMTS) and the Non-Metal Treatment System (NMTS) remove and degrade PCBs from painted surfaces. FINDINGS: AMTS decreased the Aroclor® concentration of a solution by more than 97% within 120 minutes and the Aroclor® concentration of industrial paint chips by up to 98% over three weeks. After removing up to 76% of PCBs on a painted surface after seven days, NMTS also removed trace amounts of PCBs in the paint's concrete substrate. The evaporation rate of the solvent (ethanol) from the treatment system was reduced when the application area was increased. The solvent system's ability to remove more than 90% of PCBs was maintained after losing 36% of its mass to solvent evaporation. CONCLUSIONS: The delivery systems, AMTS and NMTS, are able to support the hydrodechlorination reaction necessary for PCB degradation and are therefore attractive options for further studies regarding the remediation of contaminated painted surfaces.

SELECTION OF CITATIONS
SEARCH DETAIL
...