ABSTRACT
We report the successful salvage of cardiac implantable electronic device pulse generator protrusion sealed by the surrounding skin in a frail patient presenting 5 months after the last surgical revision. (Level of Difficulty: Advanced.).
ABSTRACT
This study evaluates per-procedure, collective and per capita effective dose to the population by interventional cardiology (IC) procedures performed during 2002-11 at the main hospital of Aosta Valley Region that can be considered as representative of the health-care level I countries, as defined by the UNSCEAR, based on its socio-demographic characteristics. IC procedures investigated were often multiple procedures in patients older than 60 y. The median extreme dose-area product values of 300 and 22 908 cGycm(2) were found for standard pacemaker implantation and coronary angioplasty, respectively, while the relative mean per-procedure effective dose ranged from 0.7 to 47 mSv. A 3-fold increase in frequency has been observed together with a correlated increase in the delivered per capita dose (0.05-0.27 mSv y(-1)) and the collective dose (5.8-35 man Sv y(-1)). Doses increased particularly from 2008 onwards mainly because of the introduction of coronary angioplasty procedures in the authors' institution. IC practice contributed remarkably in terms of effective dose to the population, delivering â¼10% of the total dose by medical ionising radiation examination categories.