Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Article in German | MEDLINE | ID: mdl-39107631

ABSTRACT

Medial clavicle fractures and injuries to the sternoclavicular joint are rare injuries but can have life-threatening consequences. There are no standardized treatment algorithms or guidelines for the diagnostics and treatment. This article provides an overview of the individual topographies as well as the conservative and surgical treatment strategies.Conservative treatment is preferred for medial clavicle fractures. The indications for surgical treatment are variable but this is frequently carried out if there is a fracture displacement > 1 cm or 1 shaft width and high functional demands. In the case of accompanying injuries to neurovascular structures, an open fracture or the threat of perforation of the skin, surgical treatment is mandatory. Open reduction and internal fixation using (locking) plates is currently the preferred form of treatment.In the case of posterior dislocation of the sternoclavicular joint, an immediate closed reduction must be attempted with the patient under analgosedation and with emergency treatment on standby. This temporal urgency does not exist for anterior and superior dislocations. Surgical treatment is indicated in cases of unsuccessful reduction, persistent symptomatic instability or injuries of the neurovascular bundle. From a multitude of treatment options, arthrodesis with suture cerclage has shown good results. Tendon grafts as well as special hook plates are increasingly being used due to better biomechanical qualities. The surgical treatment of combined injuries is determined by the individual injury pattern.Despite the variety of treatment strategies, the long-term outcome has consistently been positively described.

2.
Acta Biomater ; 180: 128-139, 2024 05.
Article in English | MEDLINE | ID: mdl-38636789

ABSTRACT

Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri­implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri­implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri­implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri­implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. STATEMENT OF SIGNIFICANCE: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n = 8 titanium and n = 8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.


Subject(s)
Benzophenones , Bone Plates , Carbon Fiber , Carbon , Inflammation , Ketones , Polyethylene Glycols , Polymers , Titanium , Humans , Ketones/chemistry , Titanium/chemistry , Titanium/adverse effects , Polyethylene Glycols/chemistry , Polymers/chemistry , Carbon Fiber/chemistry , Carbon/chemistry , Male , Inflammation/pathology , Female , Middle Aged , Aged , Adult
3.
Shoulder Elbow ; 15(2): 159-165, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37035612

ABSTRACT

Background: Open reduction and internal fixation (ORIF) of humeral head split fractures is challenging because of high instability and limited visibility. The aim of this retrospective study was to investigate the extend of the approach through the rotator interval (RI) on the reduction quality and functional outcome. Methods: 37 patients (mean age: 59 ± 16 years,16 female) treated by ORIF through a standard deltopectoral (DP) approach were evaluated. The follow-up period was at least two years. In 17 cases, the approach was extended through the RI. Evaluation was based on radiographs, Constant scores (CS) and DASH scores. Results: In group DP, "anatomic" reduction was achieved in 9 cases (45%), "acceptable" in 5 cases (25%), and "malreduced" in 6 cases (30%). In group RI, "anatomic" reduction was seen in 12 cases (71%), "acceptable" in 5 cases (29%), and "malreduced" in none (p = 0.04). In the DP group, the CS was 60.2 ± 16.2 and the %CS was 63.9 ± 22.3, while in the RI group, the CS was 74.5 ± 17.4 and the %CS was 79.1 ± 24.1 (p = 0.07, p = 0.08). DASH score was 22.8 ± 19.5 in DP compared to RI: 25.2 ± 20.6 (p = 0.53). Conclusions: The RI approach improves visualization as it enhances quality of fracture reduction, however functional outcomes may not differ significantly. Type of study and level of proof: Retrospective, level III.

4.
BMC Musculoskelet Disord ; 23(1): 95, 2022 Jan 27.
Article in English | MEDLINE | ID: mdl-35086539

ABSTRACT

BACKGROUND: Posttraumatic shoulder stiffness remains a problem after proximal humerus fracture (PHF) despite good healing rates. The aim of this pilot study was to determine whether the implant material and overlying soft tissue have an effect on shoulder range of motion (ROM) before and after implant removal (IR). METHODS: 16 patients (mean age 55.2 ± 15.3 (SD) years; 62.5% female) were included who underwent operative treatment with locking plates of either carbon fiber reinforced Polyetheretherketone (PEEK) (PEEKPower® humeral fracture plate, Arthrex, Naples, Florida, USA, n = 8) or titanium alloy (Ti) (Philos®, DePuy Synthes, Johnson & Johnson Medical, Raynham, Massachusetts, USA, n = 8) for PHF. All patients presented with a limited ROM and persistent pain in everyday life after the fracture had healed, whereupon IR was indicated. ROM before and after IR were compared as well as the Constant Score (CS) and the CS compared to the contralateral shoulder (%CS) 1 year after IR. RESULTS: In group PEEK, elevation was 116.3° ± 19.2° pre- and 129.4° ± 23.7° post-IR (p = 0.027). External rotation was 35.0° ± 7.6° pre- and 50.6° ± 21.8° post-IR (p = 0.041). External rotation with the humerus abducted 90° was 38.8° ± 18.1° pre- and 52.5° ± 25.5° post-IR (p = 0.024). In group Ti, elevation was 110.0° ± 34.6° pre- and 133.8° ± 31.1° post-IR (p = 0.011). External rotation with the humerus at rest was 33.8° ± 23.1° pre- and 48.8° ± 18.7° post-IR (p = 0.048). External rotation with the humerus abducted 90° was 40.0° ± 31.6° pre- and 52.5° ± 22.5° post-IR (p = 0.011). Comparison of the two implant materials showed no significant difference. The overall CS was 90.3 ± 8.8, the %CS was 91.8% ± 14.7%. CONCLUSION: There was no significant difference in ROM, CS and %CS with respect to plate materials, although lower cell adhesion is reported for the hydrophobic PEEK. However, all patients showed improved functional outcomes after IR in this pilot study. In patients with shoulder stiffness following locked plating for PHF, implants should be removed and open arthrolysis should be performed, independently from the hardware material. LEVEL OF EVIDENCE: II.


Subject(s)
Shoulder Fractures , Titanium , Adult , Aged , Benzophenones , Bone Plates , Female , Fracture Fixation, Internal , Humans , Humerus/diagnostic imaging , Humerus/surgery , Male , Middle Aged , Pilot Projects , Polymers , Retrospective Studies , Shoulder , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery , Treatment Outcome
5.
Osteoporos Int ; 33(4): 901-907, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34817618

ABSTRACT

This is the first study that highlighted the amount of missed information related on bone health in orthogeriatric patients suffering fragility fractures of the pelvis and also evaluated its prevalence and differing etiology in the assessed patients, regarding osteoporosis and/or osteomalacia, based on laboratory and instrumental measurements. This evaluation should become a standardized procedure in the treatment of orthogeriatric patients presenting with a FFP. INTRODUCTION: Fragility fractures of the pelvis (FFP) are common in orthogeriatric patients. Secondary fracture prevention regarding evaluation and treatment of an underlying osteoporosis or osteomalacia is still often neglected. The purpose of this study was to evaluate the amount of missed information related on bone health in older adult FFP patients, the prevalence of vitamin D deficiency in assessed patients, and if fracture type-dependent distribution patterns could be observed. METHODS: A retrospective analysis of prospectively collected data of an institutional register was performed. Patients aged 80 years and older (n = 456) admitted with a FFP from 01/2003 until 12/2019 to a level I trauma center were included. RESULTS: In 456 patients, FFP type II were leading (66.7%). Diagnostics were conducted in 37.1% of the patients regarding measurement of vitamin D levels and 21.7% regarding DXA measurements; vitamin D deficiency was observed in 62.7%, indicators for an underlying osteomalacia in 45.8%, and an osteoporosis in 46.5% of the assessed patients. CONCLUSION: Although FFP are common and will increase, there is still a lack of secondary fracture prevention, starting with information related on bone health. In the assessed patients, a high prevalence of vitamin D deficiency was present, but no significant correlation between vitamin D level and type of fracture was observed. Ongoing education for varying etiology and specific treatment of these fractures is necessary, as surgical treatment was unified, but drug therapy remains different.


Subject(s)
Bone Density , Osteoporotic Fractures , Aged , Aged, 80 and over , Humans , Osteoporotic Fractures/epidemiology , Osteoporotic Fractures/etiology , Osteoporotic Fractures/prevention & control , Pelvis , Prevalence , Retrospective Studies
6.
Radiologe ; 61(12): 1107-1114, 2021 Dec.
Article in German | MEDLINE | ID: mdl-34767032

ABSTRACT

BACKGROUND: Due to our ageing population, the number of elderly patients who are treated in the emergency department due to low-energy trauma (e.g., tripping) continues to rise. These minor accidents often result in fragility fractures classically located in the proximal humerus, distal radius, spine, pelvis, and near the hip joint. Pre-existing conditions, polypharmacy, and general frailty increase the risk of fragility fractures in this patient population. METHODS: Geriatric trauma fractures and especially insufficiency fractures of the posterior pelvic ring are often difficult to diagnose by plain X­ray. Therefore, in geriatric trauma patients, cross-sectional imaging, e.g., computed tomography (CT), dual-energy CT (DECT), or magnetic resonance imaging (MRI), should be considered early for reliable evaluation of a suspected fracture. This also allows for the identification of older fractures. Particularly in cognitively impaired elderly patients, difficult examination conditions or an unclear fall event, cross-sectional imaging is often indicated. However, this may also involve risks, e.g., use of contrast medium in patients with impaired renal function, so that each case must be considered individually. Furthermore, the diagnosis and treatment of osteoporosis, which is an underlying disease that leads to fragility fractures, is of particular importance. In the diagnostic workup, measurement of bone density using dual energy X­ray absorptiometry (DXA) is the standard method according to guidelines. In specific situations, high-resolution peripheral quantitative CT (HR-pQCT) may also be used. CONCLUSION: Due to the special challenges of correctly detecting fragility fractures and being able to quickly initiate adequate therapy, good cooperation between radiologists and trauma surgeons is necessary.


Subject(s)
Fractures, Bone , Osteoporosis , Absorptiometry, Photon , Aged , Bone Density , Humans , Tomography, X-Ray Computed
7.
Unfallchirurg ; 124(2): 108-116, 2021 Feb.
Article in German | MEDLINE | ID: mdl-33346861

ABSTRACT

Rotator cuff (RC) tears comprise a broad spectrum of lesions ranging from partial to full thickness tears of a single tendon and massive cuff tears. Both glenohumeral trauma as well as degenerative processes can result in tearing of the RC. Treatment therefore requires a meticulous diagnosis as well as a differentiated approach by careful consideration of morphological and patient-specific factors. The pathogenesis, tear morphology, clinical symptoms and functional demands of the patient determine the therapeutic approach. Despite pathological and individual patient-related factors, early surgical repair is generally recommended for traumatic RC tears in young patients and in patients with high functional demands due to the high risk of tear progression. The results of RC repair are negatively correlated with the size of the lesion, the number of tendons involved, the degree of tendon retraction, muscular alteration and patient age. This article provides an overview of the various pathogenesis, indications and surgical repair of RC tears with respect to modern pathology-specific reconstructive procedures.


Subject(s)
Rotator Cuff Injuries , Rotator Cuff , Arthroscopy , Humans , Rotator Cuff Injuries/diagnosis , Rotator Cuff Injuries/surgery , Rupture , Tendons
8.
Unfallchirurg ; 124(2): 89-95, 2021 Feb.
Article in German | MEDLINE | ID: mdl-33346862

ABSTRACT

Tendon pathologies are a frequent cause of shoulder pain and can lead to significant decline in the quality of life. Conservative treatment is suitable for most tendon pathologies. In addition to classical conservative treatment options, such as physiotherapy, oral analgesia and infiltrations, there are a number of additive treatment options to promote structural tendon healing and clinical outcome. Furthermore, there are approaches to improve the results of the surgical treatment of tendon injuries by biological augmentation. The objective of this article is to give an overview of biological and regenerative therapeutic options in the treatment of tendon injuries of the shoulder. Therefore, the anatomical and molecular biological principles of the tendon structure and their importance for tendon healing are explained in order to highlight the various therapeutic options for daily practice. Biological augmentation procedures and regenerative medicine represent a promising therapeutic option for tendon injuries of the shoulder, however, the benefits are so far supported by little or no evidence at all.


Subject(s)
Platelet-Rich Plasma , Rotator Cuff Injuries , Humans , Quality of Life , Regenerative Medicine , Rotator Cuff , Rotator Cuff Injuries/surgery , Shoulder , Tendons , Treatment Outcome
9.
Injury ; 52(3): 506-510, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32917384

ABSTRACT

BACKGROUND: The aim of this study was to evaluate functional outcomes in patients with varus malposition following open reduction and internal fixation of displaced proximal humeral fractures. METHODS: Data of 685 patients with a mean age of 67±15.8 years (67% female), that were treated by open reduction and internal fixation for a displaced proximal humeral fracture at a level 1 trauma center, were analyzed. On standardized x-ray imaging, the degree of varus displacement was measured over a minimum of two years follow-up and patients were divided into three groups. Group A: anatomic or <10° of varus or valgus malposition, group B: 10-20° of varus malposition and group C: >20° varus malposition, while anatomic head-shaft-angle was defined 135° The groups were compared with regards to functional outcomes by means of the Constant Score (CS). RESULTS: In 565 patients with anatomic to minor <10° varus or valgus malposition (Group A), the mean CS was 72.5 ± 18.8 points. The %CS to the uninjured side was 87.2 ± 24.1 and the age and gender normalized nCS was 84.7 ± 21.7. In comparison, in group B (10-20° varus) the mean CS was 64.7 ± 16.9, the mean %CS was 84.5 ± 18.3 and the mean nCS was 76.2 ± 20.6. In group C (>20° varus) the mean CS was 54.1 ± 19.5, the mean was %CS: 72.3 ± 26.4 and the mean nCS was 64.8 ± 23.8 (p = 0.02, p = 0.03, p = 0.01). Overall, the CS, %CS and nCS correlated significantly with the degree of varus position (Pearson correlation, r = 0.23, r = 0.21, r = 0.25). CONCLUSION: Varus malposition is related to inferior functional outcomes compared to anatomic healing in patients treated by open reduction and internal fixation for proximal humeral fractures. The data supports suggestions to prevent varus malposition in open reduction and internal fixation. In severe >20° of varus malposition, revision surgery should be considered.


Subject(s)
Bone Plates , Shoulder Fractures , Aged , Aged, 80 and over , Cohort Studies , Female , Follow-Up Studies , Fracture Fixation, Internal , Humans , Male , Middle Aged , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery , Treatment Outcome
10.
Unfallchirurg ; 123(6): 496-500, 2020 Jun.
Article in German | MEDLINE | ID: mdl-32140813

ABSTRACT

This article reports the case of a 42-year-old male patient, who sustained a gluteal compartment syndrome after drug-induced immobilization with subsequent rhabdomyolysis and sciatic nerve palsy. Unlike compartment syndrome of the forearm or lower leg, this is a rare condition. After immediate surgical decompression and installation of negative pressure wound treatment, hemofiltration in acute renal failure could be averted using forced diuresis. The sensorimotor function of the lower extremity improved already after the first treatment and secondary wound closure was possible after 1 week. The patient was discharged 11 days after admission with complete recovery of sensorimotor and renal functions.


Subject(s)
Acute Kidney Injury/prevention & control , Buttocks/injuries , Buttocks/surgery , Compartment Syndromes/surgery , Opioid-Related Disorders/therapy , Acute Kidney Injury/etiology , Adult , Compartment Syndromes/etiology , Decompression, Surgical , Diuresis , Diuretics/therapeutic use , Humans , Male , Negative-Pressure Wound Therapy , Opioid-Related Disorders/complications , Recovery of Function , Rhabdomyolysis/etiology , Rhabdomyolysis/surgery , Sciatic Neuropathy/etiology , Sciatic Neuropathy/surgery , Wound Closure Techniques
11.
Exp Clin Endocrinol Diabetes ; 116(8): 481-6, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18680073

ABSTRACT

The Polycystic ovary syndrome (PCOS) is the most frequent endocrine disorder in premenopausal women and is associated with features of the insulin resistance syndrome, altered glucose homeostasis, and central obesity. Inflammation appears to be a link between obesity and insulin resistance, because adipose tissue is one major source of proinflammatory cytokines. Since peroxisome proliferator-activated receptor (PPAR)gamma affects adipocyte differentiation as well as insulin sensitivity, we investigated whether the levels of proinflammatory factors in PCOS patients are related to sequence variations of the PPAR gamma gene. Proinflammatory cytokine levels, i.e. IL-1 beta, IL-6, IL-7, IL-8, IL-17 and TNFalpha, were evaluated in PCOS patients (n=21) in comparison to obese controls (n=120). Next to this the complete coding sequence of the PPAR gamma gene was investigated by resequencing all probands. We show that the levels of IL-8 and IL-17 were unchanged, IL-1 beta, IL-6 and TNFalpha were elevated and the level of IL-7 was decreased in PCOS patients compared to obese controls. Sequence analyses of the PPAR gamma gene indicated that neither the common polymorphisms P12A or H478 H, nor novel polymorphisms (E79Q, V32G, -39 T>C, c.480 +33 t > g,) or unique sequence variations (S22S, A23A, T41A, S226C, K272 T, I484I, c.819 +24 a>c) detected in this investigation revealed evidence for a direct association of PPAR gamma with altered IL-7, IL-1beta, IL-6 and TNFalpha levels in PCOS patients. So, alterations in inflammatory serum markers appear to be a feature of PCOS per se, and are independent of PPAR gamma variants.


Subject(s)
Genetic Variation , Inflammation/blood , PPAR gamma/genetics , Polycystic Ovary Syndrome/blood , Polycystic Ovary Syndrome/genetics , Adult , Biomarkers/blood , Blood Glucose/metabolism , Cholesterol/blood , Cytokines/blood , Female , Gene Frequency , Glycated Hemoglobin/metabolism , Humans , Inflammation/etiology , Inflammation/genetics
12.
Arch Dermatol ; 130(9): 1159-66, 1994 Sep.
Article in English | MEDLINE | ID: mdl-7522002

ABSTRACT

BACKGROUND AND DESIGN: Review of skin biopsy specimens showing necrotizing vasculitis revealed three patients with small dermal vessel eosinophilic vasculitis and common clinical features characterized by glucocorticoid responsive pruritic erythematous, purpuric papules and angioedema associated with peripheral blood eosinophilia. Indirect immunofluorescent localization of eosinophil granule proteins, neutrophil granule proteins, and mast cell tryptase, electron-microscopic evaluation and immunoperoxidase staining for vascular cell adhesion molecule type 1, intercellular adhesion molecule type I, endothelial-leukocyte adhesion molecule type 1, and very-late activation antigen type 4 were performed. Eosinophil-active cytokines in serum were evaluated by an eosinophil survival assay. OBSERVATIONS: Eight skin biopsy specimens from the three patients all showed small-vessel necrotizing vasculitis with exclusive eosinophil infiltration. Ultrastructural study demonstrated degenerating eosinophils and eosinophil granules in proximity to damaged endothelium. The affected small vessels showed marked deposition of the toxic eosinophil granule major basic protein in the vessel walls and expression of vascular cell adhesion molecule type 1 and intercellular adhesion molecule type 1 on the endothelium with adherence of very-late activation antigen type 4-positive eosinophils; E-selectin staining was negative. The presence of interleukin 5 in serum available from one patient was detected by an eosinophil survival assay. CONCLUSIONS: We studied three patients whose cutaneous lesions showed small-vessel eosinophilic vasculitis and who presented with recurrent glucocorticoid-responsive pruritic purpuric papules and angioedema. The presence of eosinophil-active cytokines in serum and the expression of vascular cell adhesion molecule type 1 on the endothelium of affected vessels may contribute to the selective adherence and localization of activate eosinophils. Subsequent release of cytotoxic proteins such as major basic protein may result in destruction of the endothelium in this unique syndrome.


Subject(s)
Eosinophilia/pathology , Vasculitis, Leukocytoclastic, Cutaneous/pathology , Adolescent , Adult , Cell Adhesion Molecules/analysis , Eosinophils/chemistry , Eosinophils/pathology , Female , Humans , Male , Middle Aged , Necrosis , Recurrence , Vascular Cell Adhesion Molecule-1
15.
J Wildl Dis ; 13(1): 43-6, 1977 Jan.
Article in English | MEDLINE | ID: mdl-839621

ABSTRACT

Seventeen-hundred terrestrial gastropods collected in central Maine were examined for Parelaphostrongylus tenuis and other nematodes. Prevalence of nematodes was 4 to 7% in most gastropod species, but was 19% in Pallifera spp. Cosmocercoides dukae and Rhabditis spp. were the most common nematodes recovered. Only four P. tenuis larvae (prevalence 0.1%) were found. Foci important for transmission of P. tenuis in Maine have not yet been found.


Subject(s)
Mollusca/parasitology , Nematoda , Animals , Maine
SELECTION OF CITATIONS
SEARCH DETAIL