Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Transl Radiat Oncol ; 16: 34-39, 2019 May.
Article in English | MEDLINE | ID: mdl-30949592

ABSTRACT

During exclusive curative radiotherapy for head and neck tumors, the patient's organs at risk (OAR) and target volumes frequently change size and shape, leading to a risk of higher toxicity and lower control than expected on planned dosimetry. Adaptive radiotherapy is often necessary but 1) tools are needed to define the optimal time for replanning, and 2) the subsequent workflow is time-consuming. We designed a prospective study to evaluate 1) the validity of automatically deformed contours on the daily MVCT, in order to safely use the "dose-of the day" tool to check daily if replanning is necessary; 2) the automatically deformed contours on the replanning CT and the time gained in the replanning workflow. Forty-eight patients with T3-T4 and/or involved node >2 cm head and neck squamous cell carcinomas, planned for curative radiotherapy without surgery, will be enrolled. They will undergo treatment with helical IMRT including daily repositioning MVCTs. The contours proposed will be compared weekly on intermediate planning CTs (iCTs) on weeks 3, 4, 5 and 6. On these iCTs both manual recontouring and automated deformable registration of the initial contours will be compared with the contours automatically defined on the MVCT. The primary objective is to evaluate the Dice similarity coefficient (DSC) of the volumes of each parotid gland. The secondary objectives will evaluate, for target volumes and all OARs: the DSC, the mean distance to agreement, and the average surface-to-surface distance. Time between the automatic and the manual recontouring workflows will be compared.

2.
Injury ; 41(7): 680-6, 2010 Jul.
Article in English | MEDLINE | ID: mdl-19880114

ABSTRACT

We asked whether locally applied recombinant-bone morphogenic protein-2 (rh-BMP-2) with a type I collagen carrier could enhance the consolidation phase in distraction osteogenesis and whether a dose effect could be reported. We performed unilateral transverse osteotomy of the tibia in 15 immature male rabbits. In Group I (five rabbits), 750 microg of rh-BMP-2 on the type I collagen sponge (Inductos, Medtronic) was locally applied on the day of osteotomy; the Group II animals (five rabbits) received 375 microg of the drug and the Group III (control group, five rabbits) had no local application. After 7 days, 3 weeks of distraction was begun at a rate of 0.5 mm/12 h. Starting week 2 of distraction, we assessed radiographic, ultrasonographic, and densitometric parameters once per week. Animals were sacrificed after a 3-week consolidation period. Radiographic evaluation revealed increased regenerate ossification in the rh-BMP-2 groups compared with the control group. The bone mineral content was significantly higher in the rh-BMP-2 treated groups at each time point. A dose effect is shown as densitometric parameters were significantly higher between Groups I and II. 3/5 of the Group I treated animals developed a premature bony union in the regenerate resulting in premature fusion and incomplete distraction.


Subject(s)
Bone Morphogenetic Protein 2/pharmacokinetics , Osteogenesis, Distraction/methods , Tibia/metabolism , Animals , Bone Morphogenetic Protein 2/administration & dosage , Dose-Response Relationship, Drug , Male , Osteotomy , Rabbits , Recombinant Proteins/administration & dosage , Recombinant Proteins/pharmacokinetics , Tibia/drug effects , Tibia/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...