Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Waste Manag ; 33(3): 634-44, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23085306

ABSTRACT

In Switzerland many kinds of waste, e.g. paper, metals, electrical and electronic equipment are separately collected and recycled to a large extent. The residual amount of municipal solid waste (MSW) has to be thermally treated before final disposal. Efforts to recover valuable metals from incineration residues have recently increased. However, the resource potential of critical elements in the waste input (sources) and their partitioning into recyclable fractions and residues (fate) is unknown. Therefore, a substance flow analysis (SFA) for 31 elements including precious metals (Au, Ag), platinum metal group elements (Pt, Rh) and rare earth elements (La, Ce, etc.) has been conducted in a solid waste incinerator (SWI) with a state-of-the-art bottom ash treatment according to the Thermo-Re® concept. The SFA allowed the determination of the element partitioning in the SWI, as well as the elemental composition of the MSW by indirect analysis. The results show that the waste-input contains substantial quantities of precious metals, such as 0.4 ± 0.2mg/kg Au and 5.3 ± 0.7 mg/kg Ag. Many of the valuable substances, such as Au and Ag are enriched in specific outputs (e.g. non-ferrous metal fractions) and are therefore recoverable. As the precious metal content in MSW is expected to rise due to its increasing application in complex consumer products, the results of this study are essential for the improvement of resource recovery in the Thermo-Re® process.


Subject(s)
Incineration , Metals, Rare Earth/analysis , Solid Waste/analysis , Gold/analysis , Metals/analysis , Platinum/analysis , Silver/analysis , Switzerland
2.
Environ Sci Technol ; 46(2): 628-35, 2012 Jan 17.
Article in English | MEDLINE | ID: mdl-22126427

ABSTRACT

The disposal and recovery of plastics from waste electrical and electronic equipment (WEEE) are of considerable importance, both from an environmental and an economic perspective. This paper presents the results of a study investigating current concentrations of hazardous substances in mixed plastics from WEEE and their implications for an environmentally sound recovery. The study included 53 sampling campaigns for mixed plastics from WEEE. The samples were analyzed with regard to heavy metals (cadmium, chromium, mercury, and lead) and flame retardants (PentaBDE, OctaBDE, DecaBDE, DecaBB) regulated in the RoHS Directive. Besides these substances, other brominated flame retardants known to occur in electronics (HBCD, TBBPA) as well as the total bromine and phosphorus contents were considered. Results show that no mixed plastics fraction from WEEE is completely free from substances regulated in the RoHS Directive. The lowest number and average concentrations were found in flat screen monitors. The highest concentrations were found in mixed plastics from CRT monitors and TVs. Mixed plastics fractions with high average concentrations of heavy metals originate from the treatment of small household appliances (cadmium), ICT equipment (lead), and consumer equipment (lead). Mixed plastics fractions with high average concentrations of brominated flame retardants mainly originate from the treatment of small household appliances for high temperature applications (DecaBDE), CRT monitors (OctaBDE and DecaBDE) and consumer equipment (DecaBDE), in particular CRT TVs (DecaBDE). To avoid a dissipation of hazardous substances into plastics and the environment, it is recommended that mixed plastics from WEEE are subject to a strict quality management.


Subject(s)
Electronic Waste/analysis , Environmental Pollutants/chemistry , Hazardous Substances/analysis , Plastics/chemistry , Refuse Disposal/legislation & jurisprudence , Europe , Flame Retardants , Molecular Structure , Phosphorus , Recycling , Refuse Disposal/methods
3.
Waste Manag ; 27(10): 1306-16, 2007.
Article in English | MEDLINE | ID: mdl-17008085

ABSTRACT

The chemical composition of waste of small electrical and electronic equipment (s-WEEE), a rapidly growing waste stream, was determined for selected metals (Cu, Sb, Hg etc.) and non-metals (Cl, Br, P) and PCBs. During a 3-day experiment, all output products and the s-WEEE input mass flows in a WEEE recycling plant were measured. Only output products were sampled and analyzed. Material balances were established, applying substance flow analysis (SFA). Transfer coefficients for the selected substances were also determined. The results demonstrate the capability of SFA to determine the composition of the highly heterogeneous WEEE for most substances with rather low uncertainty (2 sigma +/- 30%). The results confirm the growing importance of s-WEEE regarding secondary resource metals and potential toxic substances. Nowadays, the thirty times smaller s-WEEE turns over larger flows for many substances, compared to municipal solid waste. Transfer coefficient results serve to evaluate the separation efficiency of the recycling process and confirm--with the exception of PCB and Hg--the limitation of hand-sorting and mechanical processing to separate pollutants (Cd, Pb, etc.) out of reusable fractions. Regularly applied SFA would serve to assess the efficacy of legislative, organizational and technical measures on the WEEE.


Subject(s)
Conservation of Natural Resources/methods , Electricity , Electronics , Metals/analysis , Polychlorinated Biphenyls/analysis , Refuse Disposal/methods , Waste Management/methods , Bromides/analysis , Bromides/chemistry , Chlorine/analysis , Chlorine/chemistry , Conservation of Natural Resources/legislation & jurisprudence , Environmental Monitoring , Humans , Metals/chemistry , Phosphorus/analysis , Phosphorus/chemistry , Polychlorinated Biphenyls/chemistry , Refuse Disposal/legislation & jurisprudence , Switzerland , Time Factors , Waste Management/legislation & jurisprudence
4.
Environ Sci Technol ; 39(22): 8691-9, 2005 Nov 15.
Article in English | MEDLINE | ID: mdl-16323764

ABSTRACT

Brominated flame retardants (BFRs) are synthetic additives mainly used in electrical and electronic appliances and in construction materials. The properties of some BFRs are typical for persistent organic pollutants, and certain BFRs, in particular some polybrominated diphenyl ether (PBDE) congeners and hexabromocyclododecane (HBCD), are suspected to cause adverse health effects. Global consumption of the most demanded BFRs, i.e., penta-, octa-, and decaBDE, tetrabromobisphenol A (TBBPA), and HBCD, has doubled in the 1990s. Only limited and rather uncertain data are available regarding the occurrence of BFRs in consumer goods and waste fractions as well as regarding emissions during use and disposal. The knowledge of anthropogenic substance flows and stocks is essential for early recognition of environmental impacts and effective chemicals management. In this paper, actual levels of penta-, octa-, and decaBDE, TBBPA, and HBCD in waste electrical and electronic equipment (WEEE) as a major carrier of BFRs are presented. These BFRs have been determined in products of a modern Swiss recycling plant applying gas chromatography/electron capture detection and gas chromatography/mass spectrometry analysis. A substance flow analysis (SFA) technique has been used to characterize the flows of target substances in the recycling process from the bulk WEEE input into the output products. Average concentrations in small size WEEE, representing the relevant electric and electronic appliances in WEEE, sampled in 2003 amounted to 34 mg/kg for pentaBDE, 530 mg/kg for octaBDE, 510 mg/kg for decaBDE, 1420 mg/kg for TBBPA (as an additive), 17 mg/kg for HBCD, 5500 mg/kg for bromine, and 1700 mg/kg for antimony. In comparison to data that have been calculated by SFA for Switzerland from literature for the 1990s, these measured concentrations in small size WEEE were 7 times higher for pentaBDE, unexpectedly about 50% lower for decaBDE, and agreed fairly well for TBBPA (as an additive) and octaBDE. Roughly 60% of the total bromine input determined by SFA based on X-ray fluorescence analysis of the output materials of the recycling plant cannot be assigned to the selected BFRs. This is an indication for the presence of other brominated substances as substitutes for PBDEs in electrical and electronic equipment. The presence of BFRs, in particular PBDEs in the low grams per kilogram concentration range, in the fine dust fraction recovered in the off-gas purification system of the recycling plant reveals a high potential for BFR emissions from WEEE management and point out the importance for environmentally sound recycling and disposal technologies for BFR-containing residues.


Subject(s)
Conservation of Natural Resources , Flame Retardants/analysis , Hydrocarbons, Brominated/analysis , Antimony/analysis , Bromine/analysis , Electricity , Electronics , Electrons , Gas Chromatography-Mass Spectrometry , Industry
SELECTION OF CITATIONS
SEARCH DETAIL
...