Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Int J Radiat Oncol Biol Phys ; 109(4): 1096-1110, 2021 03 15.
Article in English | MEDLINE | ID: mdl-33181248

ABSTRACT

PURPOSE: This study investigated deep learning models for automatic segmentation to support the development of daily online dose optimization strategies, eliminating the need for internal target volume expansions and thereby reducing toxicity events of intensity modulated radiation therapy for cervical cancer. METHODS AND MATERIALS: The cervix-uterus, vagina, parametrium, bladder, rectum, sigmoid, femoral heads, kidneys, spinal cord, and bowel bag were delineated on 408 computed tomography (CT) scans from patients treated at MD Anderson Cancer Center (n = 214), Polyclinique Bordeaux Nord Aquitaine (n = 30), and enrolled in a Medical Image Computing & Computer Assisted Intervention challenge (n = 3). The data were divided into 255 training, 61 validation, 62 internal test, and 30 external test CT scans. Two models were investigated: the 2-dimensional (2D) DeepLabV3+ (Google) and 3-dimensional (3D) Unet in RayStation (RaySearch Laboratories). Three intensity modulated radiation therapy plans were generated on each CT of the internal and external test sets using either the manual, 2D model, or 3D model segmentations. The dose constraints followed the External beam radiochemotherapy and MRI based adaptive BRAchytherapy in locally advanced CErvical cancer (EMBRACE) II protocol, with reduced margins of 5 and 3 mm for the target and nodal planning target volume. Geometric discrepancies between the manual and predicted contours were assessed using the Dice similarity coefficient (DSC), distance-to-agreement, and Hausdorff distance. Dosimetric discrepancies between the manual and model doses were assessed using clinical indices on the manual contours and the gamma index. Interobserver variability was assessed for the cervix-uterus, parametrium, and vagina for the definition of the primary clinical target volume (CTVT) on the external test set. RESULTS: Average DSCs across all organs were 0.67 to 0.96, 0.71 to 0.97, and 0.42 to 0.92 for the 2D model and 0.66 to 0.96, 0.70 to 0.97, and 0.37 to 0.93 for the 3D model on the validation, internal, and external test sets. Average DSCs of the CTVT were 0.88 and 0.81 for the 2D model and 0.87 and 0.82 for the 3D model on the internal and external test sets. Interobserver variability of the CTVT corresponded to a mean (range) DSC of 0.85 (0.77-0.90) on the external test set. On the internal test set, the doses from the 2D and 3D model contours provided a CTVT V42.75 Gy >98% for 98% and 91% of the CT scans, respectively. On the external test set, these percentages were increased to 100% and 93% for the 2D and 3D models, respectively. CONCLUSIONS: The investigated models provided auto-segmentation of the cervix anatomy with similar performances on 2 institutional data sets and reasonable dosimetric accuracies using small planning target volume margins, paving the way to automatic online dose optimization for advanced adaptive radiation therapy strategies.


Subject(s)
Deep Learning , Radiotherapy Planning, Computer-Assisted/methods , Uterine Cervical Neoplasms/radiotherapy , Female , Humans , Observer Variation , Radiotherapy Dosage , Retrospective Studies , Tomography, X-Ray Computed , Uterine Cervical Neoplasms/diagnostic imaging
2.
IEEE Trans Med Imaging ; 38(2): 406-416, 2019 02.
Article in English | MEDLINE | ID: mdl-30130179

ABSTRACT

External beam radiotherapy is extensively used to treat cervical carcinomas. A single planning CT scan enables the calculation of the dose distribution. The treatment is delivered over five weeks. Large per-treatment anatomical variations may hamper the dose delivery, with the potential of an organ-at-risk (OAR) overdose and a tumor underdose. To anticipate these deformations, a recent approach proposed three planning CTs with variable bladder volumes, which had the limitation of not covering all per-treatment anatomical variations. An original patient-specific population-based library has been proposed. It consisted of generating two representative anatomies, in addition to the standard planning CT anatomy. First, the cervix and bladder meshes of a population of 20 patients (314 images) were registered to an anatomical template, using a deformable mesh registration. An iterative point-matching algorithm was developed based on local shape context (histogram of polar or cylindrical coordinates and geodesic distance to the base) and on a topology constraint filter. Second, a standard principal component analysis (PCA) model of the cervix and bladder was generated to extract the dominant deformation modes. Finally, specific deformations were obtained using posterior PCA models, with a constraint representing the top of the uterus deformation. For a new patient, the cervix-uterus and bladder were registered to the template, and the patient's modeled planning library was built according to the model deformations. This method was applied following a leave-one-patient-out cross-validation. The performances of the modeled library were compared to those of the three-CT-based library, showing an improvement in both target coverage and OAR sparing.


Subject(s)
Image Processing, Computer-Assisted/methods , Models, Statistical , Radiotherapy Planning, Computer-Assisted/methods , Cervix Uteri/diagnostic imaging , Databases, Factual , Female , Humans , Pelvis/diagnostic imaging , Reproducibility of Results , Urinary Bladder/diagnostic imaging , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy
3.
Med Phys ; 45(4): 1379-1390, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29453893

ABSTRACT

PURPOSE: In the context of adaptive radiation therapy (ART) for locally advanced cervical carcinoma (LACC), this study proposed an original cone-beam computed tomography (CBCT)-guided "Evolutive library" and evaluated it against four other known radiotherapy (RT) strategies. MATERIAL AND METHODS: For 20 patients who underwent intensity-modulated radiation therapy (IMRT) for LACC, three planning CTs [with empty (EB), intermediate (IB), and full (FB) bladder volumes], a CT scan at 20 Gy and bi-weekly CBCTs for 5 weeks were performed. Five RT strategies were simulated for each patient: "Standard RT" was based on one IB planning CT; "internal target volume (ITV)-based RT" was an ITV built from the three planning CTs; "RT with one mid-treatment replanning (MidTtReplan)" corresponded to the standard RT with a replanning at 20 Gy; "Pretreatment library ART" using a planning library based on the three planning CTs; and the "Evolutive library ART", which was the "Pretreatment library ART" strategy enriched by including some CBCT anatomies into the library when the daily clinical target volume (CTV) shape differed from the ones in the library. Two planning target volume (PTV) margins of 7 and 10 mm were evaluated. All the strategies were geometrically compared in terms of the percentage of coverage by the PTV, for the CTV and the organs at risk (OAR) delineated on the CBCT. Inadequate coverage of the CTV and OARs by the PTV was also assessed using deformable image registration. The cumulated dose distributions of each strategy were likewise estimated and compared for one patient. RESULTS: The "Evolutive library ART" strategy involved a number of added CBCTs: 0 for 55%; 1 for 30%; 2 for 5%; and 3 for 10% of patients. Compared with the other four, this strategy provided the highest CTV geometric coverage by the PTV, with a mean (min-max) coverage of 98.5% (96.4-100) for 10 mm margins and 96.2% (93.0-99.7) for 7 mm margins (P < 0.05). Moreover, this strategy significantly decreased the geometric coverage of the bowel. CTV undercoverage by PTV occurred in the anterior and superior uterine regions for all strategies. The dosimetric analysis at 7 mm similarly demonstrated that the "Evolutive library ART" increased the V42.75Gy of the CTV by 27%, 20%, 13%, and 28% compared with "Standard RT", "ITV-based RT", "MidTtReplan", and "Pretreatment library ART", respectively. The dose to the bowel was also decreased by the "Evolutive library ART" compared with that by the other strategies. CONCLUSION: The "Evolutive library ART" is a personalized ART strategy that comprises a pretreatment planning library of three CT scans, enriched for half of the patients by one to three per-treatment CBCTs. This original strategy increased both the CTV coverage and bowel sparing compared with all the other tested strategies and enables us to consider a PTV margin reduction.


Subject(s)
Cone-Beam Computed Tomography , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Radiotherapy Planning, Computer-Assisted
4.
Biomed Res Int ; 2015: 726268, 2015.
Article in English | MEDLINE | ID: mdl-25759821

ABSTRACT

In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiation therapy (IMRT). Ten DIR approaches using different registration methods (demons or B-spline free form deformation (FFD)), preprocessing, and similarity metrics were tested. Two observers identified 14 landmarks (LM) on each CT-scan to compute LM registration error. The cumulated doses estimated by each method were compared. The two most effective DIR methods were the demons and the FFD, with both the mutual information (MI) metric and the filtered CTs. The corresponding LM registration accuracy (precision) was 2.44 mm (1.30 mm) and 2.54 mm (1.33 mm), respectively. The corresponding LM estimated cumulated dose accuracy (dose precision) was 0.85 Gy (0.93 Gy) and 0.88 Gy (0.95 Gy), respectively. The mean uncertainty (difference between maximal and minimal dose considering all the 10 methods) to estimate the cumulated mean dose to the parotid gland (PG) was 4.03 Gy (SD = 2.27 Gy, range: 1.06-8.91 Gy).


Subject(s)
Head and Neck Neoplasms/radiotherapy , Radiation Monitoring/methods , Aged , Aged, 80 and over , Humans , Middle Aged , Radiation Dosage , Radiotherapy, Intensity-Modulated/methods , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...