Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Interv Card Electrophysiol ; 65(2): 429-440, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35438393

ABSTRACT

BACKGROUND: The Real-World Experience of Catheter Ablation for Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation (REAL-AF) is a multicenter prospective registry of atrial fibrillation (AF) ablation. We sought to describe the baseline workflows of REAL-AF operators. METHODS: REAL-AF enrolls high volume minimum fluoroscopy radiofrequency ablators. A 150 item questionnaire was administered to participating operators. Responses were analyzed using standard methods. RESULTS: Forty-two respondents had a mean 178.2 ± 89.2 yearly AF ablations, with 42.4 ± 11.9% being paroxysmal (PAF). Most operators performed ablation with uninterrupted or minimally interrupted anticoagulation (66.7% and 28.6%). Left atrial appendage (LAA) thrombus was most commonly ruled out with transesophageal echocardiography (33.3% and 42.9% for PAF and persistent AF). Consistent with registry design, radiofrequency energy (92.1% ± 18.8% of cases) and zero fluoroscopy ablation (73.8% goal 0 fluoroscopy) were common. The majority of operators relied on index-guided ablation (90.5%); Mean Visitag surpoint targets were higher anteriorly vs posteriorly (508.3 ± 49.8 vs 392.3 ± 37.0, p < 0.01), but power was similar. There was considerable heterogeneity related to gaps in current knowledge, such as lesion delivery targets and sites of extra-pulmonary vein ablation (most common was the posterior wall followed by the roof). Peri-procedural risk factor management of obesity, hypertension, and sleep apnea was common. There was a mean of 3.0 ± 1.2 follow-up visits at 12 months. CONCLUSIONS: REAL-AF operators were high volume low fluoroscopy "real world" operators with good follow-up and adherence to known best-practices. There was disagreement related to knowledge gaps in guidelines.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Diseases , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Recurrence , Treatment Outcome , Catheter Ablation/methods , Pulmonary Veins/surgery , Registries
3.
J Innov Card Rhythm Manag ; 13(10): 5196-5201, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36605293

ABSTRACT

Atrial fibrillation (AF) represents a significant health care burden in the United States that will continue to increase as the population ages; thus, the introduction of cost-effective strategies to limit this burden is critical. The establishment of dedicated electrophysiology programs focusing on AF care within hospitals can improve patient care while providing added financial benefits for institutions if properly planned and delivered. This paper explains how to develop an efficient and quality-focused AF ablation program as part of a larger AF center of excellence by highlighting the experience of a single center and demonstrating how the same principles were adopted to implement a similar program at another institution.

4.
J Interv Card Electrophysiol ; 62(3): 487-494, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34212280

ABSTRACT

PURPOSE: Catheter ablation has become a mainstay therapy for atrial fibrillation (AF) with rapid innovation over the past decade. Variability in ablation techniques may impact efficiency, safety, and efficacy; and the ideal strategy is unknown. Real-world evidence assessing the impact of procedural variations across multiple operators may provide insight into these questions. The Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal (PAF) and Persistent (PsAF) Atrial Fibrillation registry (Real-AF) is a multicenter prospective registry that will enroll patients at high volume centers, including academic institutions and private practices, with operators performing ablations primarily with low fluoroscopy when possible. The study will also evaluate the contribution of advent in technologies and workflows to real-world clinical outcomes. METHODS: Patients presenting at participating centers are screened for enrollment. Data are collected at the time of procedure, 10-12 weeks, and 12 months post procedure and include patient and detailed procedural characteristics, with short and long-term outcomes. Arrhythmia recurrences are monitored through standard of care practice which includes continuous rhythm monitoring at 6 and 12 months, event monitors as needed for routine care or symptoms suggestive of recurrence, EKG performed at every visit, and interrogation of implanted device or ILR when applicable. RESULTS: Enrollment began in January 2018 with a single site. Additional sites began enrollment in October 2019. Through May 2021, 1,243 patients underwent 1,269 procedures at 13 institutions. Our goal is to enroll 4000 patients. DISCUSSION: Real-AF's multiple data sources and detailed procedural information, emphasis on high volume operators, inclusion of low fluoroscopy operators, and use of rigorous standardized follow-up methodology allow systematic documentation of clinical outcomes associated with changes in ablation workflow and technologies over time. Timely data sharing may enable real-time quality improvements in patient care and delivery. Trial registration Clinicaltrials.gov: NCT04088071 (registration date: September 12, 2019).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Humans , Prospective Studies , Recurrence , Registries , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...