Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Mem Inst Oswaldo Cruz ; 118: e220202, 2023.
Article in English | MEDLINE | ID: mdl-36946838

ABSTRACT

BACKGROUND: The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES: The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS: Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS: The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS: The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19 Testing , Biological Assay , Chromosome Mapping
3.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1422150

ABSTRACT

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

4.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1430842

ABSTRACT

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

5.
Braz J Infect Dis ; 25(2): 101542, 2021.
Article in English | MEDLINE | ID: mdl-33587923

ABSTRACT

In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Subject(s)
Chikungunya Fever , Chikungunya virus , Dengue Virus , Dengue , Zika Virus Infection , Zika Virus , Brazil , Chikungunya Fever/diagnosis , Chikungunya virus/genetics , Dengue/diagnosis , Dengue Virus/genetics , Humans , Laboratories , Zika Virus/genetics , Zika Virus Infection/diagnosis
6.
Braz. j. infect. dis ; 25(2): 101542, 2021. tab
Article in English | LILACS | ID: biblio-1278571

ABSTRACT

ABSTRACT In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Subject(s)
Humans , Zika Virus/genetics , Zika Virus Infection/diagnosis , Brazil , Chikungunya virus/genetics , Dengue/diagnosis , Dengue Virus/genetics , Chikungunya Fever/diagnosis , Laboratories
7.
Am J Trop Med Hyg ; 100(1): 174-177, 2019 01.
Article in English | MEDLINE | ID: mdl-30398138

ABSTRACT

The potential for transfusion transmission of dengue virus (DENV), chikungunya virus (CHIKV), and Zika virus (ZIKV) has raised concerns about the safety of the blood supply in endemic areas. In this study, nucleic acid testing (NAT) for ZIKV, DENV, and CHIKV RNA was performed in asymptomatic blood donor samples in the city of Campinas, located in the southeast region of Brazil (1962 in 2015 and 1775 in 2016). The prevalence of reactive NAT was 0.15% in 2015 and 0.62% in 2016 for dengue, 0.05% in 2015 and 0.17% in 2016 for Zika, and 0% in both years for chikungunya. These results demonstrate the weakness of the clinical interview in screening these blood donors. Furthermore, positivity for ZIKV was detected in March 2015, 1 year before the first reported cases in the region. These data attest the feasibility of using donor samples held in library as a tool for retrospective epidemiological evaluation, which is particularly interesting considering emerging pathogens, for which data on their spread and penetrance are initially scarce.


Subject(s)
Blood Donors , Blood Safety , Zika Virus Infection/epidemiology , Zika Virus Infection/transmission , Zika Virus/isolation & purification , Antibodies, Viral/blood , Brazil/epidemiology , Chikungunya Fever/blood , Chikungunya Fever/epidemiology , Chikungunya virus/isolation & purification , Coinfection/blood , Coinfection/epidemiology , Coinfection/virology , Dengue/blood , Dengue/epidemiology , Dengue Virus/isolation & purification , Disease Outbreaks/prevention & control , Female , Genotype , Humans , Male , Mass Screening , Molecular Diagnostic Techniques/statistics & numerical data , RNA, Viral/genetics , Retrospective Studies , Surveys and Questionnaires , Zika Virus Infection/blood
8.
Transfusion ; 58(4): 862-870, 2018 04.
Article in English | MEDLINE | ID: mdl-29383720

ABSTRACT

BACKGROUND: The history of the development and implementation of the Brazilian nucleic acid testing (NAT) platform to detect and discriminate among human immunodeficiency virus (HIV), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections in blood donors is described here. The results for the sensitivity, reproducibility, and NAT yield of the platform since program implementation are provided. STUDY DESIGN AND METHODS: The Brazilian NAT HIV, HCV, and HBV kit was developed and evaluated with regard to analytical sensitivity, specificity, intralot and interlot reproducibility, interfering substances, and genotype and diagnostic sensitivity. Additionally, a sample of identified NAT-yield cases was characterized with regard to viral load. RESULTS: The 95% limits of detection for HIV, HCV, and HBV were 68.02, 102.35, and 9.08 IU/mL, respectively. All replicates were detected with reproducibility assays between the acceptable values. A total of 13,610,536 blood donors was screened from 2010 to 2016, and 63 HIV-yield cases and 28 HCV-yield cases were detected. Among 5,795,424 blood donors screened for HBV from 2014 to 2016, 42 yield cases were found. CONCLUSION: The Brazilian NAT HIV, HCV, and HBV kit is an automated NAT system suitable for routine blood donor screening in a completely traceable process. The analytical sensitivity as well as the diagnostic sensitivity fulfilled all requirements set by the health ministry for blood donor screening. A significant number of transmission cases were prevented by the implementation of this important program.


Subject(s)
Blood Donors , Blood Safety , DNA, Viral/blood , HIV Infections/diagnosis , Hepatitis B/diagnosis , Hepatitis C/diagnosis , Real-Time Polymerase Chain Reaction , Viremia/diagnosis , Automation , Blood Safety/instrumentation , Blood Safety/methods , Blood Safety/standards , Brazil , HIV Infections/blood , Hepatitis B/blood , Hepatitis C/blood , Humans , Mass Screening/methods , Real-Time Polymerase Chain Reaction/instrumentation , Real-Time Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/standards , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Viral Load , Viremia/transmission
9.
Rev Inst Med Trop Sao Paulo ; 56(4): 363-5, 2014.
Article in English | MEDLINE | ID: mdl-25076441

ABSTRACT

Bartonella henselae is associated with a wide spectrum of clinical manifestations, including cat scratch disease, endocarditis and meningoencephalitis, in immunocompetent and immunocompromised patients. We report the first molecularly confirmed case of B. henselae infection in an AIDS patient in state of Rio de Janeiro, Brazil. Although DNA sequence of B. henselae has been detected by polymerase chain reaction in a lymph node biopsy, acute and convalescent sera were nonreactive.


Subject(s)
AIDS-Related Opportunistic Infections/diagnosis , Bartonella henselae/isolation & purification , Cat-Scratch Disease/diagnosis , Adult , Animals , Bartonella henselae/genetics , Cats , DNA, Bacterial/analysis , Humans , Male , Polymerase Chain Reaction
10.
Rev. Inst. Med. Trop. Säo Paulo ; 56(4): 363-365, Jul-Aug/2014. graf
Article in English | LILACS | ID: lil-716416

ABSTRACT

Bartonella henselae is associated with a wide spectrum of clinical manifestations, including cat scratch disease, endocarditis and meningoencephalitis, in immunocompetent and immunocompromised patients. We report the first molecularly confirmed case of B. henselae infection in an AIDS patient in state of Rio de Janeiro, Brazil. Although DNA sequence of B. henselae has been detected by polymerase chain reaction in a lymph node biopsy, acute and convalescent sera were nonreactive.


Bartonella henselae está associada a um amplo espectro de manifestações clínicas, incluindo a doença da arranhadura de gato, endocardite, e meningoencefalite, em pacientes imunocompetentes e imunocomprometidos. Relatamos o primeiro caso confirmado por método molecular de B. henselae em um paciente com SIDA no estado do Rio de Janeiro, Brasil. Apesar da sequência de DNA de B. henselae ser detectada pela reação em cadeia da polimerase em uma biópsia do linfonodo, soros das fases aguda e convalescente foram não reativos.


Subject(s)
Adult , Animals , Cats , Humans , Male , AIDS-Related Opportunistic Infections/diagnosis , Bartonella henselae/isolation & purification , Cat-Scratch Disease/diagnosis , Bartonella henselae/genetics , DNA, Bacterial/analysis , Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL
...