Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
Surg Radiol Anat ; 46(2): 231-233, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38238595

ABSTRACT

PURPOSE: Knowing the anatomical variation of the coeliac trunk (CT) and its detailed interpretation in the preoperative period is important for the prevention of iatrogenic injury during liver surgery or endovascular intervention on the coeliac trunk and its branches. METHODS: A diagnostic abdominal computed tomography angiography (CTA) was performed in a 61-year-old male patient, who was investigated for a liver cancer and chemoembolization was planned. RESULTS: CTA reveals that right hepatic artery (RHA) arises directly from the abdominal aorta, at the level of CT. This vessel coursing to the right hepatic lobe, functioning therefore as a replaced right hepatic artery (RRHA). Also, the left gastric artery (LGA) arises directly from the abdominal aorta. This patient successfully underwent chemoembolization from RRHA. CONCLUSION: We presented a case of new anatomical variation involving the origination of RRHA and LGA from the abdominal aorta.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Humans , Male , Middle Aged , Aorta, Abdominal/diagnostic imaging , Gastric Artery , Hepatic Artery/diagnostic imaging , Hepatic Artery/surgery , Liver Neoplasms/therapy
3.
Struct Heart ; 6(5): 100086, 2022 Oct.
Article in English | MEDLINE | ID: mdl-37288061

ABSTRACT

Background: Endovascular baroreflex amplification with the MobiusHD, a self-expanding stent-like device that is implanted in the internal carotid artery, was designed to reduce the sympathetic overactivity that contributes to progressive heart failure with reduced ejection fraction. Methods: Symptomatic patients (New York Heart Association class III) with heart failure with reduced ejection fraction (left ventricular ejection fraction [LVEF] ≤40%) despite guideline directed medical therapy and n-terminal pro-B type natriuretic peptide (NT-proBNP) levels ≥400 pg/mL in whom carotid ultrasound and computed tomographic angiography demonstrated absence of carotid plaque were enrolled. Baseline and follow-up measures included 6-minute walk distance (6MWD), Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ OSS), and repeat biomarkers and transthoracic echocardiography. Results: Twenty-nine patients underwent device implantation. The mean age was 60.6 ± 11.4 years, and all had New York Heart Association class III symptoms. Mean KCCQ OSS was 41.4 ± 12.7, mean 6MWD was 216.0 ± 43.7 m, median NT-proBNP was 1005.9 pg/mL (894, 1294), and mean LVEF was 34.7 ± 2.9%. All device implantations were successful. Two patients died (161 days and 195 days) and one stroke occurred (170 days) during follow-up. For the 17 patients with 12-month follow-up, mean KCCQ OSS improved by 17.4 ± 9.1 points, mean 6MWD increased by 97.6 ± 51.1 meters, a mean 28.4% reduction from the baseline NT-proBNP concentration was found, and mean LVEF improved by 5.6% ± 2.9 (paired data). Conclusion: Endovascular baroreflex amplification with the MobiusHD device was safe and effected positive changes in quality of life, exercise capacity, and LVEF, consistent with observed reductions in NT-proBNP levels.

4.
Catheter Cardiovasc Interv ; 71(7): 921-6, 2008 Jun 01.
Article in English | MEDLINE | ID: mdl-18412251

ABSTRACT

OBJECTIVES: This study evaluated the feasibility of percutaneous patent foramen ovale (PFO) closure using a transcatheter suture (Superstitch), leaving no device behind. BACKGROUND: PFO has been implicated in cryptogenic strokes and migraine with auras. Percutaneous PFO closure, being less invasive than surgical closure, is increasingly performed. There are, however, early and long-term risks including device embolization, fracture, thrombosis, or infection, erosions into the free atrial wall and aorta, arrhythmias, and death. Furthermore, device implantation may complicate future percutaneous access to the left atrium. Partially reabsorbable devices and tissue welding to close PFO have recently been introduced. The first-in-man transcatheter suture closure of a PFO in an 18-year-old female with chronic migraine with aura and a well documented stroke is described. METHODS: The right femoral vein was cannulated under mild sedation and local anesthesia. Using intracardiac echocardiography imaging, bubble study demonstrated a right-to-left shunt through the PFO at rest. A Superstitch device was advanced across the PFO and sutures were delivered through the septum primum and secundum. The sutures were exteriorized and a knot was advanced to the right atrial septum and cut. RESULTS: Bubble study confirmed successful PFO suture closure. Transesophageal and transthoracic echocardiograms with bubble studies at 1 and 2 months, respectively showed complete closure with no right-to-left shunt even during Valsalva maneuver. At 6 months, the patient remained free of symptoms or migraine episodes. CONCLUSION: Percutaneous transcatheter suture closure of a PFO can be successfully achieved with no residual shunt and leaving no device behind. Technological refinements are required for wider scale use.


Subject(s)
Cardiac Catheterization , Cardiac Surgical Procedures/instrumentation , Foramen Ovale, Patent/surgery , Migraine with Aura/etiology , Stroke/etiology , Surgical Staplers , Suture Techniques/instrumentation , Adolescent , Chronic Disease , Echocardiography, Transesophageal , Equipment Design , Female , Fluoroscopy , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/pathology , Humans , Migraine with Aura/surgery , Stroke/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...