Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
J Clin Med ; 13(4)2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38398401

ABSTRACT

Aims: We report 30-day, 1-year, and 3-year outcomes for a new TAVR programme that used five different transcatheter heart valve (THV) systems. Methods: From 2014 to 2020, 122 consecutive patients with severe aortic stenosis (AS) received TAVR based on the Heart Team decision. Outcomes were analysed for the whole study population and in addition the first 63 patients (Cohort A, 2014 to 2019) were compared to the last 59 patients (Cohort B, 2019 to 2020). Outcomes included VARC-2 definitions and device performance assessed via transthoracic echocardiography by independent high-volume investigators. Results: The mean patient age was 77.9 ± 6.1 years old, and 48 (39.3%) were male. The mean logistic Euroscore II was 4.2 ± 4.5, and the mean STS score was 6.9 ± 4.68. The systems used were as follows: Medtronic Corevalve Evolute R/PRO (82 patients-67.2%); Abbott Portico (13-10.6%); Boston Scientific Lotus (10-8.2%); Meril Myval (11-9%); and Boston Scientific Neo Accurate (6-5%). Access was transfemoral (95.9% of patients); surgical cut down (18% vs. percutaneous 77.8%); subclavian (n = 2); trans-axillary (n = 2); and direct aorta (n = 1). VARC-2 outcomes were as follows: device success rate 97.5%; stroke rate 1.6%; major vascular complication 3.3%; permanent pacemaker implantation 12.4%. At discharge, the incidences of grade I and II aortic regurgitation were 39.95 and 55.5%, respectively. At one year, all-cause mortality was 7.4% without admissions for valve-related dysfunction. The 3-year all-cause mortality and all-stroke rates were 22.9% and 4.1%, respectively. Between the 1-year and 3-year follow-ups, valve-related dysfunction was detected in three patients; one had THV system endocarditis that led to death. There was a remarkable but statistically non-significant decrease in mortality from Cohort A to Cohort B [four (6.3%) vs. one patient (1.7%), p = 0.195] and major vascular complications occurred at a significantly higher rate in the Cohort B [zero (0%) vs. four (6.8% patient, p = 0.036)]. Overall, we found that using multiple devices was safe and allowed for a learning team to achieve a high device success rate from the beginning (97.5%). Conclusions: TAVR with different THV systems showed acceptable early and mid-term outcomes for survival, technical success, and valve-related adverse events in high-risk patients with significant AS, even in the learning curve phase.

2.
J Clin Med ; 13(2)2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38256647

ABSTRACT

Aims: To report our single-center data regarding the initial 52 consecutive patients with a bicuspid aortic valve who underwent a Transcatheter Aortic Valve Implantation (TAVI) procedure using the new balloon-expandable MYVAL system. The focus is on reporting procedural details and outcomes over the 30-day postoperative period. Methods: From December 2019 to July 2023, 52 consecutive patients underwent a TAVI procedure with bicuspid anatomy. All patients had moderate to-high surgical risk or were unsuitable for surgical aortic valve replacement based on the Heart Team's decision. Outcomes were analyzed according to the VARC-2 criteria. The results of bicuspid patients were compared to patients with tricuspid anatomy in the overall study group, and further analysis involved a comparison between 52 pairs after propensity score matching. The device performance was evaluated using transthoracic echocardiography. Data collection was allowed by the Local Ethical Committee. Results: The mean age was 71 ± 7.1 years, and 65.4% were male. The mean Euroscore II and STS score were 3.3 ± 3.2 and 5.2 ± 3.3, respectively. Baseline characteristics and echocardiographic parameters were well balanced even in the unmatched comparison. Procedures were significantly longer in the bicuspid group and resulted in a significantly higher ARI index. All relevant anatomic dimensions based on the CT scans were significantly higher in bicuspid anatomy, including a higher implantation angulation, a higher rate of horizontal aorta and a higher proportion of patients with aortopathy. In the unmatched bicuspid vs. tricuspid comparison, postprocedural outcomes were as follows: in-hospital mortality 0% vs. 1.4% (p = 0.394), device success 100% vs. 99.1% (p = 0.487), TIA 1.9% vs. 0% (p = 0.041), stroke 1.9% vs. 0.9% (p = 0.537), major vascular complication 3.8% vs. 2.3% (p = 0.530), permanent pacemaker implantation 34% vs. 30.4% (p = 0.429), and cardiac tamponade 0% vs. 0.5% (p = 0.624). In the propensity-matched bicuspid vs. tricuspid comparison, postprocedural outcomes were as follows: in-hospital mortality 0% vs. 0%, device success 100% vs. 100%, TIA 1.9% vs. 0% (p = 0.315), stroke 1.9% vs. 0.9% (p = 0.315), major vascular complication 3.8% vs. 0% (p = 0.475), permanent pacemaker implantation 34% vs. 24% (p = 0.274), and cardiac tamponade 0% vs. 0%. There was no annular rupture nor need for second valve or severe aortic regurgitation in both the unmatched and matched comparison. The peak and mean aortic gradients did not differ at discharge and at 30-day follow-up between the two groups regardless of whether the comparison was unmatched or matched. There were no paravalvular leakages (moderate or above) in the bicuspid patients. Intermediate and extra sizes of the Myval THV system used a significantly higher proportion in bicuspid anatomy with a significantly higher oversize percentage in tricuspid anatomy. Conclusions: The TAVI procedure using the Myval THV system in patients with significant aortic stenosis and bicuspid aortic valve anatomy is safe and effective. Hemodynamic parameters do not differ between tricuspid and bicuspid patients. However, the permanent pacemaker implantation rate is higher than expected; its relevance on long-term survival is controversial.

3.
Catheter Cardiovasc Interv ; 102(7): 1317-1330, 2023 12.
Article in English | MEDLINE | ID: mdl-37870123

ABSTRACT

AIMS: To report our single-center data, regarding the first 100 patients who underwent TAVR procedure with the new balloon-expandable MYVAL system. We report 30-day and 1-year outcomes in low to high-risk TAVR patient population. METHODS: From November 2019 to July 2021, 100 consecutive patients underwent TAVR procedure. Patient outcome was classified according to the VARC-2 definitions. The device performance was assessed using transthoracic echocardiography. Data collection was allowed by the Local Ethical Committee. RESULTS: The mean age was 74.7 years, 63 (63%) were male. The mean Euroscore II and STS score were 4.8 ± 4.9 and 5.6 ± 3.9, respectively. Transfemoral access was the most frequent (surgical vs. percutaneous 2% vs. 97%) and in one patient surgical subclavian access was used. VARC-2 outcomes were as follows: device success 99%, STROKE 1%, major and minor vascular complication was 1% and 11%, respectively, the rate of new permanent pacemaker implantation was 30.7%. At discharge, the incidence of grade I, grade II aortic regurgitation was 39% and 1%, respectively, without relevant PVL. In-hospital mortality was only 1%. These results included a high proportion (17%) of patients with bicuspid aortic valves. At 1 year, the all-cause mortality rate was 7% (only two due to cardiac event) and only a single patient had valve-related dysfunction requiring surgical aortic replacement. CONCLUSIONS: TAVR procedure with MYVAL transcatheter heart valve system shows excellent 30-day and 1-year outcomes regarding patient survival, technical success, and valve-related adverse events. The limitations of our study comprise a single-center study with retrospective data collection.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Follow-Up Studies , Retrospective Studies , Treatment Outcome , Prosthesis Design
4.
Orv Hetil ; 158(35): 1390-1395, 2017 Sep.
Article in Hungarian | MEDLINE | ID: mdl-28847178

ABSTRACT

INTRODUCTION: Several studies have demonstrated that the prevalence of heart disease can be accounted for between 0.4 and 2% in developed countries. AIM: The present study aimed to use the PA% of the telemetry data to estimate the 6-minute walk test result. METHOD: A total of seventeen patients with heart disease; 3 females and 14 males; age: 57.35 yrs ± 9.54; body mass 98.71 ± 9.89 kg; average BMI 36.69 ± 3.67 were recruited into the study. Using the two sets of values describing physical performance, linear regression was calculated providing a mathematical equation, thus, the Physical Activity % value is used to estimate the distance traveled over a 6-minute walk test. RESULTS: On further data analysis, we have come to the conclusion that the distance walked during the six-minute-long test may be measured by PA% from the data of CRT device. CONCLUSIONS: With our method, based on the values received from the physical activity sensor implanted into the resynchronisation devices, changes in patients' health status could be monitored telemetrically with the assistance from the implanted electronic device. Orv Hetil. 2017; 158(35): 1390-1395.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure/therapy , Telemetry/methods , Walk Test/methods , Walking Speed/physiology , Adult , Female , Heart Failure/physiopathology , Humans , Male , Middle Aged , Motor Activity
5.
Orv Hetil ; 158(19): 748-753, 2017 May.
Article in Hungarian | MEDLINE | ID: mdl-28490242

ABSTRACT

INTRODUCTION: The effect of regular physical activity on health is widely recognized, but several studies have shown its key importance for heart patients. AIM: The present study aimed to define the PA % values, and to convert them into metabolic equivalent values (MET), which describes oxygen consumption during physical activity. METHOD: A total of seventeen patients with heart disease; 3 females and 14 males; age: 57.35 yrs ± 9.54; body mass 98.71 ± 9.89 kg; average BMI 36.69 ± 3.67 were recruited into the study. The measured values from Cardiac Resynchronisation Therapy devices and outer accelerometers (ActiGraph GT3X+) were studied over a 7-day time period. Using the two sets of values describing physical performance, linear regression was calculated providing a mathematical equation, thus, the Physical Activity values in percentage were converted into MET values. RESULTS: During the 6-minute walk test the patients achieved an average of 416.6 ± 48.2 m. During 6MWT the measured values averaged at 1.85 ± 0.18 MET's, and MET values averaged at 1.12 ± 0.06 per week. It clearly shows that this test is a challenge for the patients compared to their daily regular physical activity levels. CONCLUSION: With our method, based on the values received from the physical activity sensor implanted into the resynchronisation devices, changes in patients' health status could be monitored telemetrically with the assistance from the implanted electronic device. Orv Hetil. 2017; 158(17): 748-753.


Subject(s)
Cardiac Resynchronization Therapy , Exercise , Health Status , Telemetry/methods , Aged , Female , Heart Failure/therapy , Humans , Male , Middle Aged , Motor Activity , Walking
SELECTION OF CITATIONS
SEARCH DETAIL
...