Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730391

ABSTRACT

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Subject(s)
Benzophenones , Crowns , Dental Abutments , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Finite Element Analysis , Titanium , Titanium/chemistry , Humans , Dental Porcelain/chemistry , Polyethylene Glycols/chemistry , Dental Materials/chemistry , Polymers , Ketones/chemistry , Zirconium/chemistry , Dental Implants, Single-Tooth , Materials Testing , Dental Implant-Abutment Design , Biomechanical Phenomena
2.
J Prosthodont ; 2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37434476

ABSTRACT

PURPOSE: To evaluate the effect of restorative materials with or without resin content, modeled on zirconia and titanium abutment materials, on the stress distribution on the alveolar bone, implant, and prosthetic crowns with a 3D finite element stress analysis. MATERIAL AND METHODS: Titanium and zirconia abutments were combined with three implant-supported crown materials (polymer infiltrated hybrid ceramic (PICN), lithium disilicate (LD), and zirconia-reinforced lithium silicate (ZLS)) to create six experimental groups. The 40 × 30 × 20 mm alveolar bone, 3.75 × 10 mm implant, esthetic abutment, and maxillary first premolar crown bonded over the abutment were the components of the finite element models. On the lingual cusp of the crown, the 150 N occlusal loading was applied in the buccolingual direction at a 30° angle. Equivalent von Mises stress and maximum and minimum principal stresses were used for both the qualitative and quantitative evaluation of the stress distribution of the created models. RESULTS: The von Mises stress in implant and abutment did not differ according to the crown materials. The use of a zirconia abutment resulted in higher von Mises stress values in the abutment but lower stress values in the implant. The highest stress values were obtained in ZLS (196.65 MPa) and LD (194.05 MPa) crowns. The use of titanium abutments, regardless of crown materials, resulted in higher von Mises stress values in restorative crowns than in zirconia abutments. The principal stress values in alveolar bone showed similar distribution and concentration in all models. CONCLUSIONS: Changes in crown material did not affect stress distribution in the implant and peripheral bone. However, the zirconia esthetic abutment resulted in a lower stress concentration on the implant.

3.
Article in English | MEDLINE | ID: mdl-35410030

ABSTRACT

This study aimed to investigate the effect of different cleansing solutions on the retention of precision attachments. A precision attachment patrix was embedded into acrylic resin and the matrix was placed onto the patrix. The red (high retention, 8 N), yellow (regular retention, 6 N), and green (reduced retention, 4 N) plastic matrixes of the attachments (n = 32) were soaked in three different denture cleansing solutions (sodium laureth sulfate, sodium bicarbonate-sodium perborate, sodium bicarbonate) for a duration simulating 6 months of clinical use. The control group was soaked in tap water. A universal testing machine was used to measure the retention values of attachments after they were soaked in denture cleansers. The retention values were compared among the groups with repeated-measures analysis of variance followed by the Tukey HSD test (p = 0.05). Yellow attachments were affected by sodium laureth sulfate, sodium bicarbonate-sodium perborate, and water (p = 0.012). Green attachments' retention increased after immersion in sodium laureth sulfate (p = 0.04) and water (p = 0.02). Red attachments' retention increased after immersion in sodium laureth sulfate or sodium bicarbonate-sodium perborate (p = 0.045). Water did not affect the retention of red attachments. Because sodium bicarbonate tablets did not affect the retention of attachments, clinicians may recommend their use as a cleanser. Clinicians also may inform patients using fixed and removable partial prostheses with precision attachments of a possible increase in retention after the use of sodium laureth sulfate or when using sodium bicarbonate-sodium perborate with yellow and red attachments.


Subject(s)
Denture Cleansers , Denture Retention , Acrylic Resins , Humans , Sodium Bicarbonate , Water