Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Surg ; 38(6): 1422-5, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14681652

ABSTRACT

The use of endovascular stent grafts in the repair of thoracic aortic aneurysms has provided an alternative means of treatment, particularly in the high-risk patient who may not tolerate conventional open repair. The combination of conventional surgery and endovascular repair may allow for successful treatment in patients with anatomy unsuitable for repair entirely by endovascular means alone. We present the case of a patient with a syphilitic thoracic aortic aneurysm involving the aortic arch and descending thoracic aorta. He underwent a staged repair with an elephant trunk reconstruction of the aortic arch followed by endovascular repair of the descending thoracic aorta. This is the first reported case of the repair of a syphilitic aneurysm by means of endovascular techniques.


Subject(s)
Angioplasty/methods , Aortic Aneurysm, Thoracic/surgery , Syphilis, Cardiovascular/surgery , Humans , Male , Middle Aged
2.
J Vasc Surg ; 38(4): 676-83, 2003 Oct.
Article in English | MEDLINE | ID: mdl-14560212

ABSTRACT

OBJECTIVES: Endovascular stent-graft repair has great potential in treatment of thoracic aortic aneurysms. This study analyzed a single center's experience with first-generation commercially produced thoracic stent grafts used to treat descending thoracic aortic aneurysms. METHODS: Over 58 months 84 patients underwent endovascular stent-graft repair of descending thoracic aortic aneurysms; 22 patients received the Gore TAG stent graft, and 62 patients received the Talent thoracic endovascular stent-graft system. Each patient was enrolled in one of three distinct US Food and Drug Administration trials at Mount Sinai Medical Center in accordance with strict inclusion and exclusion criteria, including suitability for open surgery, aneurysm anatomy, and presence of comorbid medical illness. Mean age of this cohort was 71 +/- 12 years. There were 54 men and 30 women, and 74 (88%) had three or more comorbid illnesses. Primary technical success was achieved in 76 patients (90%). Mean follow-up was 15 months (range, 0-52 months). RESULTS: Successful aneurysm exclusion was achieved in 69 patients (82%). Major procedure-related or device-related complications occurred in 32 patients (38%). There were six proximal attachment failures (8%), four distal attachment failures (6%), one intergraft failure (1%), two mechanical device failures (3%), five periprocedural deaths (6%), and five late aneurysm ruptures (6%). At 40 months, overall survival was 67% (+/-10%), and freedom from rupture or from type I or type III endoleak was 74% (+/-10%). CONCLUSION: While promising, this midterm experience with commercially available devices highlights the shortcomings of current stent-graft technology. Three significant advancements are required to fulfill the potential of this important treatment method: a stent graft with a durable proximal and distal fixation device, enhanced engineering to accommodate high thoracic aortic fatigue forces, and a mechanism to adapt to aortic arch and visceral segment branches to enable treatment of lesions that extend to or include these vessels.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Stents , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Postoperative Complications , Prosthesis Failure , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL
...