Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Stud Health Technol Inform ; 142: 62-7, 2009.
Article in English | MEDLINE | ID: mdl-19377115

ABSTRACT

Robotic surgery has gradually gained acceptance due to its numerous advantages such as tremor filtration, increased dexterity and motion scaling. There remains, however, a significant scope for improvement, especially in the areas of surgeon-robot interface and autonomous procedures. Previous studies have attempted to identify factors affecting a surgeon's performance in a master-slave robotic system by tracking hand movements. These studies relied on conventional optical or magnetic tracking systems, making their use impracticable in the operating room. This study concentrated on building an intrinsic movement capture platform using microcontroller based hardware wired to a surgical robot. Software was developed to enable tracking and analysis of hand movements while surgical tasks were performed. Movement capture was applied towards automated movements of the robotic instruments. By emulating control signals, recorded surgical movements were replayed by the robot's end-effectors. Though this work uses a surgical robot as the platform, the ideas and concepts put forward are applicable to telerobotic systems in general.


Subject(s)
Computers , Motion , Robotics/instrumentation , Surgery, Computer-Assisted , Humans , Software , Telemedicine
2.
Surg Endosc ; 23(4): 727-33, 2009 Apr.
Article in English | MEDLINE | ID: mdl-18622547

ABSTRACT

BACKGROUND: Technical advances in the application of laparoscopic and robotic surgical systems have improved platform usability. The authors hypothesized that using two monitors instead of one would lead to faster performance with fewer errors. METHODS: All tasks were performed using a surgical robot in a training box. One of the monitors was a standard camera with two preset zoom levels (zoomed in and zoomed out, single-monitor condition). The second monitor provided a static panoramic view of the whole surgical field. The standard camera was static at the zoomed-in level for the dual-monitor condition of the study. The study had two groups of participants: 4 surgeons proficient in both robotic and advanced laparoscopic skills and 10 lay persons (nonsurgeons) who were given adequate time to train and familiarize themselves with the equipment. Running a 50-cm rope was the basic task. Advanced tasks included running a suture through predetermined points and intracorporeal knot tying with 3-0 silk. Trial completion times and errors, categorized into three groups (orientation, precision, and task), were recorded. RESULTS: The trial completion times for all the tasks, basic and advanced, in the two groups were not significantly different. Fewer orientation errors occurred in the nonsurgeon group during knot tying (p=0.03) and in both groups during suturing (p=0.0002) in the dual-monitor arm of the study. Differences in precision and task error were not significant. CONCLUSIONS: Using two camera views helps both surgeons and lay persons perform complex tasks with fewer errors. These results may be due to better awareness of the surgical field with regard to the location of the instruments, leading to better field orientation. This display setup has potential for use in complex minimally invasive surgeries such as esophagectomy and gastric bypass. This technique also would be applicable to open microsurgery.


Subject(s)
Computer Terminals/standards , Digestive System Surgical Procedures/methods , Monitoring, Intraoperative/instrumentation , Robotics/instrumentation , Suture Techniques/instrumentation , Equipment Design , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...