Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 92(4): 044708, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243427

ABSTRACT

We describe a method of analyzing gate profile data for ultrafast x-ray imagers that allows pixel-by-pixel determination of temporal sensitivity in the presence of substantial background oscillations. With this method, systematic timing errors in gate width and gate arrival time of up to 1 ns (in a 2 ns wide gate) can be removed. In-sensor variations in gate arrival and gate width are observed, with variations in each up to 0.5 ns. This method can be used to estimate the coarse timing of the sensor, even if errors up to several ns are present.

2.
Phys Rev E ; 103(3): L031201, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33862680

ABSTRACT

Achieving a high conversion efficiency into relativistic electrons is central to short-pulse laser application and fundamentally relies on creating interaction regions with intensities ≫10^{18}W/cm^{2}. Small focal length optics are typically employed to achieve this goal; however, this solution is impractical for large kJ-class systems that are constrained by facility geometry, debris concerns, and component costs. We fielded target-mounted compound parabolic concentrators to overcome these limitations and achieved nearly an order-of-magnitude increase to the conversion efficiency and more than tripled electron temperature compared to flat targets. Particle-in-cell simulations demonstrate that plasma confinement within the cone and formation of turbulent laser fields that develop from cone wall reflections are responsible for the improved laser-to-target coupling. These passive target components can be used to improve the coupling efficiency for all high-intensity short-pulse laser applications, particularly at large facilities with long focal length optics.

3.
Rev Sci Instrum ; 92(3): 033506, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33820043

ABSTRACT

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single "Furi" hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual "Icarus" sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium-triterium experiments, enable significantly greater return of data per experiment.

4.
Rev Sci Instrum ; 81(10): 10D921, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033953

ABSTRACT

Backscattered light via laser-plasma instabilities has been measured in early NIF hohlraum experiments on two beam quads using a suite of detectors. A full aperture backscatter system and near backscatter imager (NBI) instrument separately measure the stimulated Brillouin and stimulated Raman scattered light. Both instruments work in conjunction to determine the total backscattered power to an accuracy of ∼15%. In order to achieve the power accuracy we have added time-resolution to the NBI for the first time. This capability provides a temporally resolved spatial image of the backscatter which can be viewed as a movie.

5.
Rev Sci Instrum ; 81(10): 10E121, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033986

ABSTRACT

Moderately priced oscilloscopes available for the NIF power sensors and target diagnostics have 6 GHz bandwidths at 20-25 Gsamples/s (40 ps sample spacing). Some NIF experiments require cross timing between instruments be determined with accuracy better than 30 ps. A simple analysis algorithm for Gaussian-like pulses such as the 100-ps-wide NIF timing fiducial can achieve single-event cross-timing precision of 1 ps (1/50 of the sample spacing). The midpoint-timing algorithm is presented along with simulations that show why the technique produces good timing results. Optimum pulse width is found to be ∼2.5 times the sample spacing. Experimental measurements demonstrate use of the technique and highlight the conditions needed to obtain optimum timing performance.

6.
Opt Lett ; 24(3): 160-2, 1999 Feb 01.
Article in English | MEDLINE | ID: mdl-18071440

ABSTRACT

We have developed a hybrid Ti:sapphire-Nd:glass laser system that produces more than 1500 TW (1.5 PW) of peak power. The system produces 660 J of power in a compressed 440+/-20 fs pulse by use of 94-cm master diffraction gratings. Focusing to an irradiance of >7x10(20) W/cm (2) is achieved by use of a Cassegrainian focusing system employing a plasma mirror.

SELECTION OF CITATIONS
SEARCH DETAIL
...