Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38475148

ABSTRACT

Ensuring precise angle measurement during surgical correction of orientation-related deformities is crucial for optimal postoperative outcomes, yet there is a lack of an ideal commercial solution. Current measurement sensors and instrumentation have limitations that make their use context-specific, demanding a methodical evaluation of the field. A systematic review was carried out in March 2023. Studies reporting technologies and validation methods for intraoperative angular measurement of anatomical structures were analyzed. A total of 32 studies were included, 17 focused on image-based technologies (6 fluoroscopy, 4 camera-based tracking, and 7 CT-based), while 15 explored non-image-based technologies (6 manual instruments and 9 inertial sensor-based instruments). Image-based technologies offer better accuracy and 3D capabilities but pose challenges like additional equipment, increased radiation exposure, time, and cost. Non-image-based technologies are cost-effective but may be influenced by the surgeon's perception and require careful calibration. Nevertheless, the choice of the proper technology should take into consideration the influence of the expected error in the surgery, surgery type, and radiation dose limit. This comprehensive review serves as a valuable guide for surgeons seeking precise angle measurements intraoperatively. It not only explores the performance and application of existing technologies but also aids in the future development of innovative solutions.


Subject(s)
Surgery, Computer-Assisted , Surgery, Computer-Assisted/methods , Fluoroscopy/methods
2.
Bone Joint Res ; 12(12): 712-721, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38043570

ABSTRACT

Aims: Research on hip biomechanics has analyzed femoroacetabular contact pressures and forces in distinct hip conditions, with different procedures, and used diverse loading and testing conditions. The aim of this scoping review was to identify and summarize the available evidence in the literature for hip contact pressures and force in cadaver and in vivo studies, and how joint loading, labral status, and femoral and acetabular morphology can affect these biomechanical parameters. Methods: We used the PRISMA extension for scoping reviews for this literature search in three databases. After screening, 16 studies were included for the final analysis. Results: The studies assessed different hip conditions like labrum status, the biomechanical effect of the cam, femoral version, acetabular coverage, and the effect of rim trimming. The testing and loading conditions were also quite diverse, and this disparity limits direct comparisons between the different researches. With normal anatomy the mean contact pressures ranged from 1.54 to 4.4 MPa, and the average peak contact pressures ranged from 2 to 9.3 MPa. Labral tear or resection showed an increase in contact pressures that diminished after repair or reconstruction of the labrum. Complete cam resection also decreased the contact pressure, and acetabular rim resection of 6 mm increased the contact pressure at the acetabular base. Conclusion: To date there is no standardized methodology to access hip contact biomechanics in hip arthroscopy, or with the preservation of the periarticular soft-tissues. A tendency towards improved biomechanics (lower contact pressures) was seen with labral repair and reconstruction techniques as well as with cam correction.

3.
Membranes (Basel) ; 13(3)2023 Mar 17.
Article in English | MEDLINE | ID: mdl-36984734

ABSTRACT

In this paper, we propose an optimized protocol to synthesize reproducible, accurate, sustainable integrally skinned monophasic hybrid cellulose acetate/silica membranes for ultrafiltration. Eight different membrane compositions were studied, divided into two series, one and two, each composed of four membranes. The amount of silica increased from 0 wt.% up to 30 wt.% (with increments of 10 wt.%) in each series, while the solvent composition was kept constant within each series (formamide/acetone ratio equals 0.57 wt.% in series one and 0.73 wt.% in series two). The morphology of the membranes was analyzed by scanning electron microscopy and the chemical composition by Fourier transform infrared spectroscopy, in attenuated total reflection mode (FTIR-ATR). Mechanical tensile properties were determined using tensile tests, and a retest trial was performed to assess mechanical properties variability over different membrane batches. The hydraulic permeability of the membranes was evaluated by measuring pure water fluxes following membrane compaction. The membranes in series two produced with a higher formamide/acetone solvent ratio led to thicker membranes with higher hydraulic permeability values (47.2-26.39 kg·h-1·m-2·bar-1) than for the membranes in series one (40.01-19.4 kg·h-1·m-2·bar-1). Results obtained from the FTIR-ATR spectra suggest the presence of micro/nano-silica clusters in the hybrid membranes of series one, also exhibiting higher Young's modulus values than the hybrid membranes in series two.

4.
J Exp Orthop ; 9(1): 94, 2022 Sep 19.
Article in English | MEDLINE | ID: mdl-36117186

ABSTRACT

PURPOSE: Little is known about the direct influence of different technical options at the rotator cuff tendon-bone interface (TBI) and, more specifically, at the medial bearing row (MBR), regarding local contact force, area and pressure. We evaluated the mechanical repercussions of different medial row anchor configurations for that setting using different values of tension in the lateral row anchors. METHODS: Knotless transosseous equivalent (TOE) rotator cuff repairs with locked versus nonlocked medial anchors and single versus double-hole suture passage were tested in a synthetic rotator cuff mechanical model, using 2 different values of lateral row tension. Contact force, area, pressure, peak force and MBR force were compared at the simulated TBI using a pressure mapping sensor. RESULTS: When compared to locked anchors, medial row sliding configurations generate lower values for all the above-mentioned parameters. The use of double-hole suture passage in the medial cuff generated slightly higher values contact area regardless of lateral row tension. At higher lateral row tension values, lower values of the remaining parameters, including MBR force, were found when compared to single-hole suture passage. Lateral row anchor tension increase induced an increase of all parameters regardless of the medial row configuration and TBI contact force and MBR force were the most susceptible parameters, regardless of the medial row pattern. CONCLUSION: Medial row mechanism, suture configuration and lateral row tension interfere with the mechanical force, area and pressure at by TBI. Lateral row tension increase is a major influencer in those parameters. These results can help surgeons choose the right technique considering its mechanical effect at the TBI.

5.
Membranes (Basel) ; 12(9)2022 Aug 24.
Article in English | MEDLINE | ID: mdl-36135845

ABSTRACT

The production of medical devices follows strict guidelines where bio- and hemocompatibility, mechanical strength, and tear resistance are important features. Segmented polyurethanes (PUs) are an important class of polymers that fulfill many of these requirements, thus justifying the investigation of novel derivatives with enhanced properties, such as modulated carbon dioxide and oxygen permeability. In this work, three segmented polyurethane-based membranes, containing blocks of hard segments (HSs) dispersed in a matrix of soft segment (SS) blocks, were prepared by reacting a PU prepolymer (PUR) with tris(hydroxymethyl)aminomethane (TRIS), Congo red (CR) and methyl-ß-cyclodextrin (MBCD), rendering PU/TRIS, PU/CR and PU/MBCD membranes. The pure (control) PU membrane exhibited the highest degree of phase segregation between HSs and SSs followed by PU/TRIS and PU/MBCD membranes, and the PU/CR membrane displayed the highest degree of mixing. Pure PU and PU/CR membranes exhibited the highest and lowest values of Young's modulus, tangent moduli and ultimate tensile strength, respectively, suggesting that the introduction of CR increases molecular mobility, thus reducing stiffness. The CO2 permeability was highest for the PU/CR membrane, 347 Barrer, and lowest for the pure PU membrane, 278 Barrer, suggesting that a higher degree of mixing between HSs and SSs leads to higher CO2 permeation rates. The permeability of O2 was similar for all membranes, but ca. 10-fold lower than the CO2 permeability.

6.
Comput Methods Biomech Biomed Engin ; 25(13): 1459-1470, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34919009

ABSTRACT

This work presents Motion Envelopes (ME), a simple method to estimate the missing longitudinal rotations of minimal stick figures, which is based on the spatial-temporal surface traced by line segments that connect contiguous pairs of joints. We validate ME by analyzing the gait patterns of 6 healthy subjects, comprising a total of 18 gait cycles. A strong correlation between experimental and estimated data was obtained for lower limbs and upper arms, indicating that ME can predict their longitudinal orientation in normal gait, hence, ME can be used to complement the kinematic information of stick figures whenever it is incomplete.


Subject(s)
Canes , Walking , Biomechanical Phenomena , Gait , Humans , Motion
7.
J Exp Orthop ; 8(1): 9, 2021 Feb 03.
Article in English | MEDLINE | ID: mdl-33537914

ABSTRACT

PURPOSE: Knotless repairs have demonstrated encouraging performance regarding retear rate reduction, but literature aiming at identifying the specific variables responsible for these results is scarce and conflictive. The purpose of this paper was to evaluate the effect of the material (tape or wire suture) and medial tendon passage (single or double passage) on the contact force, pressure and area at the tendon bone interface in order to identify the key factors responsible for this repairs´ success. METHODS: A specific knotless transosseous equivalent cuff repair was simulated using 2 tape or suture wire loaded medial anchors and 2 lateral anchors, with controlled lateral suture limb tension. The repair was performed in a previously validated sawbones® mechanical model. Testing analyzed force, pressure and area in a predetermined and constant size "repair box" using a Tekscan® sensor, as well as peak force and pressure, force applied by specific sutures and force variation along the repair box. RESULTS: Tapes generate lower contact force and pressure and double medial passage at the medial tendon is associated with higher contact area. Suture wires generate higher peak force and pressure on the repair and higher mean force in their tendon path and at the medial bearing row. Force values decrease from medial to lateral and from posterior to anterior independently of the material or medial passage. CONCLUSION: Contrary to most biomechanical literature, suture tape use lowers the pressure and force applied at the tendon bone junction, while higher number of suture passage points medially increases the area of contact. These findings may explain the superior clinical results obtained with the use uf suture tapes because its smaller compressive effect over the tendon may create a better perfusion environment healing while maintaining adequate biomechanical stability.

SELECTION OF CITATIONS
SEARCH DETAIL
...