1.
JVS Vasc Sci ; 5: 100198, 2024.
Article in English | MEDLINE | ID: mdl-38846626

ABSTRACT

Objective: Strain has become a viable index for evaluating abdominal aortic aneurysm stability after endovascular aneurysm repair (EVAR). In addition, literature has shown that healthy aortic tissue requires a degree of strain to maintain homeostasis. This has led to the hypothesis that too much strain reduction conferred by a high degree of graft oversizing is detrimental to the aneurysm neck in the seal zone of abdominal aortic aneurysms after EVAR. We investigated this in a laboratory experiment by examining the effects that graft oversizing has on the pressure-normalized strain ( ε ρ + ¯ /pulse pressure [PP]) reduction using four different infrarenal EVAR endografts and our ultrasound elastography technique. Approximate graft oversizing percentages were 20% (30 mm phantom-graft combinations), 30% (28 mm phantom-graft combinations), and 50% (24 mm phantom-graft combinations). Methods: Axisymmetric, 10% by mass polyvinyl alcohol phantoms were connected to a flow simulator. Ultrasound elastography was performed before and after implantation with the four different endografts: (1) 36 mm polyester/stainless steel, (2) 36 mm polyester/electropolished nitinol, (3) 35 mm polytetrafluoroethylene (PTFE)/nitinol, and (4) 36 mm nitinol/polyester/platinum-iridium. Five ultrasound cine loops were taken of each phantom-graft combination. They were analyzed over two different cardiac cycles (end-diastole to end-diastole), yielding a total of 10 maximum mean principal strain ( ε ρ + ¯ ) values. ε ρ + ¯ was divided by pulse pressure to yield pressure-normalized strain ( ε ρ + ¯ /PP). An analysis of variance was performed for graft comparisons. We calculated the average percent ε ρ + ¯ /PP reduction by manufacturer and percent oversizing. These values were used for linear regression analysis. Results: Results from one-way analysis of variance showed a significant difference in ε ρ + ¯ /PP between the empty phantom condition and all oversizing conditions for all graft manufacturers (F(3, 56) = 106.7 [graft A], 132.7 [graft B], 106.5 [graft C], 105.7 [graft D], P < .0001 for grafts A-D). There was a significant difference when comparing the 50% condition with the 30% and 20% conditions across all manufacturers by post hoc analysis (P < .0001). No significant difference was found when comparing the 20% and 30% oversizing conditions for any of the manufacturers or when comparing ε ρ + ¯ /PP values across the manufacturers according to percent oversize. Linear regression demonstrated a significant positive correlation between the percent graft oversize and the all-graft average percent ε ρ + ¯ /PP reduction ( R 2  = 0.84, P < .0001). Conclusions: This brief report suggests that a 10% increase in graft oversizing leads to an approximate 5.9% reduction in ε ρ + ¯ /PP on average. Applied clinically, this increase may result in increased stiffness in axisymmetric vessels after EVAR. Further research is needed to determine if this is clinically significant.

2.
Front Cardiovasc Med ; 10: 1232844, 2023.
Article in English | MEDLINE | ID: mdl-37719977

ABSTRACT

Introduction: Current abdominal aortic aneurysm (AAA) assessment relies on analysis of AAA diameter and growth rate. However, evidence demonstrates that AAA pathology varies among patients and morphometric analysis alone is insufficient to precisely predict individual rupture risk. Biomechanical parameters, such as pressure-normalized AAA principal wall strain (ερ+¯/PP, %/mmHg), can provide useful information for AAA assessment. Therefore, this study utilized a previously validated ultrasound elastography (USE) technique to correlate ερ+¯/PP with the current AAA assessment methods of maximal diameter and growth rate. Methods: Our USE algorithm utilizes a finite element mesh, overlaid a 2D cross-sectional view of the user-defined AAA wall, at the location of maximum diameter, to track two-dimensional, frame-to-frame displacements over a full cardiac cycle, using a custom image registration algorithm to produce ερ+¯/PP. This metric was compared between patients with healthy aortas and AAAs (≥3 cm) and compared between small and large AAAs (≥5 cm). AAAs were then separated into terciles based on ερ+¯/PP values to further assess differences in our metric across maximal diameter and prospective growth rate. Non-parametric tests of hypotheses were used to assess statistical significance as appropriate. Results: USE analysis was conducted on 129 patients, 16 healthy aortas and 113 AAAs, of which 86 were classified as small AAAs and 27 as large. Non-aneurysmal aortas showed higher ερ+¯/PP compared to AAAs (0.044 ± 0.015 vs. 0.034 ± 0.017%/mmHg, p = 0.01) indicating AAA walls to be stiffer. Small and large AAAs showed no difference in ερ+¯/PP. When divided into terciles based on ερ+¯/PP cutoffs of 0.0251 and 0.038%/mmHg, there was no difference in AAA diameter. There was a statistically significant difference in prospective growth rate between the intermediate tercile and the outer two terciles (1.46 ± 2.48 vs. 3.59 ± 3.83 vs. 1.78 ± 1.64 mm/yr, p = 0.014). Discussion: There was no correlation between AAA diameter and ερ+¯/PP, indicating biomechanical markers of AAA pathology are likely independent of diameter. AAAs in the intermediate tercile of ερ+¯/PP values were found to have nearly double the growth rates than the highest or lowest tercile, indicating an intermediate range of ερ+¯/PP values for which patients are at risk for increased AAA expansion, likely necessitating more frequent imaging follow-up.

3.
J Vasc Surg Cases Innov Tech ; 8(4): 762-769, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36438670

ABSTRACT

Objective: Predicting success after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) relies on measurements of aneurysm sac regression. However, in the absence of regression, morphometric analysis alone is insufficient to reliably predict the successful remodeling of AAAs after EVAR. Biomechanical parameters, such as pressure-normalized principal strain, might provide useful information in the post-EVAR AAA assessment. Our objective was to assess the feasibility of our novel ultrasound elastography (USE) technique to detect changes in the aortic wall principal strain in patients who had undergone EVAR and determine the temporal nature of the biomechanical changes in the aorta. Methods: USE images were obtained from patients undergoing elective EVAR intraoperatively, immediately before and after endograft implantation, and at their 30-day follow-up. The maximal mean principal strain ( ε ρ + ¯ ) for each scan was assessed using our novel technique, which uses a finite element mesh to track the frame-to-frame displacements of the aortic wall over one cardiac cycle. The ε ρ + ¯ in the user-defined aortic wall was then divided by the pulse pressure at the time of the scan to produce a pressure-normalized strain measurement ( ε ρ + ¯ /PP), a surrogate for tissue stiffness. Paired t tests were used to compare the pre- and postoperative ε ρ + ¯ /PP and the postoperative and 30-day ε ρ + ¯ /PP. Patient 30-day sac regression and endoleak data were collected by a review of 30-day follow-up computed tomography scans. Results: USE analysis of the data from 12 patients demonstrated a significant reduction in aortic wall ε ρ + ¯ /PP (average, 0.191% ± 0.09%/kPa vs 0.087% ± 0.04%/kPa; P = .002) immediately after graft implantation, with a nonsignificant change in the ε ρ + ¯ /PP (0.091% ± 0.04%/kPa vs 0.102% ± 0.05%/kPa; P = .47) from postoperatively to 30-day follow-up. This represents an average 46.5% reduction after stent placement, with a nonsignificant 18.1% increase at 30-day follow-up. All the patients showed sac stability, except for two patients who had demonstrated 7.3-mm and 6.8-mm sac regressions. Conclusions: Our analysis has demonstrated that the presented USE technique is a feasible method for detecting significant reductions in aortic ε ρ + ¯ /PP intraoperatively after EVAR. We found that patients undergoing EVAR will experience large reductions in the ε ρ + ¯ /PP intraoperatively after graft implantation, with stabilization found at their 30-day follow-up. These preliminary data have shown that an intraoperative ε ρ + ¯ /PP reduction could be a promising correlate of post-EVAR aneurysm remodeling. Our results have also suggested that endograft design likely plays a large role in determining the aneurysm biomechanical changes immediately after implantation.