Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Cardiothorac Surg ; 19(1): 305, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38816838

ABSTRACT

BACKGROUND: Cardiac hemangiomas are very uncommon benign primary tumors. They are usually located preferentially in the right atrium and their location in the interatrial septum is extremely rare. CASE PRESENTATION: We report the case of a 41-year-old patient who was admitted due to a stroke. The transthoracic echocardiogram revealed a large mass in the right atrium adhered to the interatrial septum. Suspecting an atrial myxoma, surgical intervention was performed confirming that the mass extended within the thickness of the interatrial septum, protruding into the right atrial cavity. The histologic report confirmed a hemangioma. CONCLUSIONS: Cardiac hemangiomas are rare primary tumors and are usually misdiagnosed as other cardiac tumors. Histopathological examination is essential for a definitive diagnosis.


Subject(s)
Atrial Septum , Echocardiography , Heart Neoplasms , Hemangioma , Humans , Heart Neoplasms/surgery , Heart Neoplasms/diagnosis , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/pathology , Adult , Hemangioma/diagnosis , Hemangioma/surgery , Hemangioma/diagnostic imaging , Atrial Septum/diagnostic imaging , Atrial Septum/surgery , Atrial Septum/pathology , Male , Diagnosis, Differential , Heart Atria/diagnostic imaging , Heart Atria/pathology , Female
3.
J Hosp Med ; 11(11): 778-784, 2016 11.
Article in English | MEDLINE | ID: mdl-27264844

ABSTRACT

BACKGROUND: Prognostication of patients hospitalized with acute decompensated heart failure (ADHF) is important to patients, providers, and healthcare systems. Few bedside tools exist to prognosticate patients hospitalized with ADHF. OBJECTIVE: The objective of this study was to assess the relationship between inferior vena cava (IVC) diameter and postdischarge mortality in patients hospitalized with ADHF. DESIGN: Prospective observational study. SETTING: A 247-bed urban teaching hospital in Spain PATIENTS: Ninety-seven patients hospitalized with ADHF. INTERVENTION: None. MEASUREMENTS: The IVC diameter and collapsibility were measured by a hospitalist at the time of admission and discharge. Primary outcome was 90-day all-cause mortality. Secondary outcomes were readmission rates at 90 and 180 days, and 180-day all-cause mortality. Patients were followed for 180 days. RESULTS: Data from 80 patients were analyzed. From admission to discharge, a significant improvement in IVC maximum (IVCmax ) diameter (2.12 vs 1.87 cm; P < 0.001) and IVC collapsibility (25.7% vs 33.1%; P < 0.001) was seen in the total study cohort. During the 90-day follow-up period, 11 patients (13.7%) died. An admission IVCmax diameter ≥1.9 cm was associated with a higher mortality rate at 90 days (25.4% vs 3.4%; P = 0.009) and 180 days (29.3% vs 3.4%; P = .003). In a multivariate Cox proportional hazards regression analysis, admission IVCmax diameter was an independent predictor of 90-day mortality (hazard ratio [HR]: 5.88; 95% confidence interval [CI]: 1.21-28.10; P = 0.025) and 90-day readmission (HR: 3.20; 95% CI: 1.24-8.21; P = 0.016). CONCLUSION: In patients hospitalized with acute decompensated heart failure, a dilated IVC by bedside ultrasound at the time of admission is associated with a higher 90-day mortality after hospitalization. Journal of Hospital Medicine 2016;11:778-784. © 2016 Society of Hospital Medicine.


Subject(s)
Heart Failure/mortality , Hospitalization , Ultrasonography/statistics & numerical data , Vena Cava, Inferior/diagnostic imaging , Acute Disease , Aged , Aged, 80 and over , Female , Heart Failure/diagnostic imaging , Humans , Male , Patient Readmission , Prospective Studies , Spain , Time Factors , Ultrasonography/methods
4.
Rev Port Cardiol ; 35(3): 133-8, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26919889

ABSTRACT

INTRODUCTION AND OBJECTIVES: To investigate the incidence and clinical relevance of the presence of mobile echogenic images (MEI) during transesophageal echocardiography (TEE) for monitoring of transcatheter aortic valve implantation (TAVI). METHODS: Consecutive patients referred to our center for transfemoral or transapical TAVI were included. The procedure was monitored by three-dimensional (3D) TEE and images were analyzed by two independent experts. In-hospital follow-up was carried out and correlated with imaging findings. RESULTS: A total of 104 patients were included. MEI were visualized in 11 patients during the procedure (11%) and in over 50% of cases were identified as thrombi, however no differences in periprocedural stroke were found in follow-up. CONCLUSIONS: Visualization of MEI during 3D TEE monitoring of TAVI is relatively common (11%) and in over 50% of cases they are identified as thrombi. The clinical implications of this finding are uncertain, as despite their frequency, the incidence of clinical stroke in this patient population was no higher. 3D TEE is a useful tool for diagnosis of MEI and can alert the operator to their presence.


Subject(s)
Aortic Valve Stenosis/diagnosis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Imaging, Three-Dimensional , Incidence
5.
Rev Port Cardiol ; 34(11): 665-72, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26604049

ABSTRACT

INTRODUCTION: A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. OBJECTIVE: To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. METHODS: We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. RESULTS: A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). CONCLUSION: The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Pacemaker, Artificial , Aortic Valve/surgery , Cardiac Catheterization/adverse effects , Electrocardiography , Heart Valve Prosthesis/adverse effects , Humans , Incidence , Treatment Outcome
6.
Rev Port Cardiol ; 31(2): 143-9, 2012 Feb.
Article in Portuguese | MEDLINE | ID: mdl-22240099

ABSTRACT

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is an alternative to surgical aortic valve replacement in patients with severe aortic stenosis (AS) and unacceptably high surgical risk. METHODS: We present our first two years' experience with TAVI. A total of 76 AS patients were evaluated for TAVI and 23 of them underwent a TAVI procedure. These patients had a mean EuroSCORE of 22.4% and a mean age of 81.5 years, and were prospectively followed for a mean of 12.9 ± 11 months. RESULTS: The percutaneous aortic valve was successfully implanted in 100% of the patients. Mortality at 30 days was 4%. The most common complications were access site-related bleeding and transfusion (22%), followed by new permanent pacemaker implantation (9%). After a mean follow-up of 12.9 months, survival was 87%. In a maximum follow-up of 30 months there were no cases of prosthesis dysfunction or cardiovascular death. CONCLUSIONS: Two years after the introduction of a TAVI program in our center, the procedure has established itself as a safe and effective alternative for patients with severe AS and unacceptably high surgical risk.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Female , Humans , Male , Prospective Studies , Prosthesis Design , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...