Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38793995

ABSTRACT

A broadband differential-MMIC low-noise amplifier (DLNA) using metamorphic high-electron-mobility transistors of 70 nm in Gallium Arsenide (70 nm GaAs mHEMT technology) is presented. The design and results of the performance measurements of the DLNA in the frequency band from 1 to 16 GHz are shown, with a high dynamic range, and a noise figure (NF) below 1.3 dB is obtained. In this work, two low-noise amplifiers (LNAs) were designed and manufactured in the OMMIC foundry: a dual LNA, which we call balanced, and a differential LNA, which we call DLNA. However, the paper focuses primarily on DLNA because of its differential architecture. Both use a 70 nm GaAs mHEMT space-qualified technology with a cutoff frequency of 300 GHz. With a low power bias Vbias/Ibias (5 V/40.5 mA), NF < 1.07 dB "on wafer" was achieved, from 2 to 16 GHz; while with the measurements made "on jig", NF = 1.1 dB, from 1 to 10 GHz. Furthermore, it was obtained that NF < 1.5 dB, from 1 to 16 GHz, with a figure of merit equal to 145.5 GHz/mW. Finally, with the proposed topology, several LNAs were designed and manufactured, both in the OMMIC process and in other foundries with other processes, such as UMS. The experimental results showed that the NF of the DLNA MMIC with multioctave bandwidth that was built in the frequency range of the L-, S-, C-, and X-bands was satisfactory.

2.
Cancers (Basel) ; 16(4)2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38398184

ABSTRACT

Early analysis and diagnosis of breast tumors is essential for either quickly launching a treatment or for seeing the evolution of patients who, for instance, have already undergone chemotherapy treatment. Once tissues are excised, histological analysis is the most frequent tool used to characterize benign or malignant tumors. Dielectric microwave spectroscopy makes use of an open-ended coaxial probe in the 1-8 GHz frequency range to quickly identify the type of tumor (ductal carcinoma, lobular carcinoma, mucinous carcinoma and fibroadenoma). The experiment was undertaken with data from 70 patients who had already undergone chemotherapy treatment, which helped to electrically map the histological tissues with their electric permittivity. Thus, the variations in the permittivity of different types of tumors reveal distinctive patterns: benign tumors have permittivity values lower than 35, while malignant ones range between 40 and 60. For example, at a frequency of 2 GHz, the measured permittivity was 45.6 for ductal carcinoma, 33.1 for lobular carcinoma, 59.5 for mucinous carcinoma, and 27.6 for benign tumors. This differentiation remains consistent in a frequency range of 1 to 4.5 GHz. These results highlight the effectiveness of these measurements in the classification of breast tumors, providing a valuable tool for quick and accurate diagnosis and effective treatment.

3.
Sensors (Basel) ; 23(23)2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38067975

ABSTRACT

In this paper, the precise design of a high-power amplifier (HPA) is shown, along with the problems associated with the stability of "on-wafer" measurements. Here, techniques to predict possible oscillations are discussed to ensure the stability of a monolithic microwave-integrated circuit (MMIC). In addition, a deep reflection is made on the instabilities that occur when measuring both on wafer and using a mounted chip. Stability techniques are used as tools to characterize measurement results. Both a precise design and instabilities are shown through the design of a three-stage X-band HPA in gallium nitride (GaN) from the WIN Semiconductors Corp. foundry. As a result, satisfactory performance was obtained, achieving a maximum output power equal to 42 dBm and power-added efficiency of 32% at a 20 V drain bias. In addition to identifying critical points in the design or measurement of the HPA, this research shows that the stability of the amplifier can be verified through a simple analysis and that instabilities are often linked to errors in the measurement process or in the characterization of the measurement process.

4.
Sensors (Basel) ; 22(22)2022 Nov 20.
Article in English | MEDLINE | ID: mdl-36433581

ABSTRACT

In this paper, a comparative analysis between the PM2.5 concentration in downtown Quito, Ecuador, during the COVID-19 pandemic in 2020 and the previous five years (from 2015 to 2019) was carried out. Here, in order to fill in the missing data and achieve homogeneity, eight datasets were constructed, and 35 different estimates were used together with six interpolation methods to put in the estimated value of the missing data. Additionally, the quality of the estimations was verified by using the sum of squared residuals and the following correlation coefficients: Pearson's r, Kendall's τ, and Spearman's ρ. Next, feature vectors were constructed from the data under study using the wavelet transform, and the differences between feature vectors were studied by using principal component analysis and multidimensional scaling. Finally, a robust method to impute missing data in time series and characterize objects is presented. This method was used to support the hypothesis that there were significant differences between the PM2.5 concentration in downtown Quito in 2020 and 2015-2019.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , Pandemics , Communicable Disease Control , Research Design , Particulate Matter
5.
Sensors (Basel) ; 21(1)2021 Jan 03.
Article in English | MEDLINE | ID: mdl-33401639

ABSTRACT

This paper analyzes 12 years of tropospheric ozone (O3) concentration measurements using robust techniques. The measurements were taken at an air quality monitoring station called Belisario, which is in Quito, Ecuador; the data collection time period was 1 January 2008 to 31 December 2019, and the measurements were carried out using photometric O3 analyzers. Here, the measurement results were used to build variables that represented hours, days, months, and years, and were then classified and categorized. The index of air quality (IAQ) of the city was used to make the classifications, and robust and nonrobust confidence intervals were used to make the categorizations. Furthermore, robust analysis methods were compared with classical methods, nonparametric methods, and bootstrap-based methods. The results showed that the analysis using robust methods is better than the analysis using nonrobust methods, which are not immune to the influence of extreme observations. Using all of the aforementioned methods, confidence intervals were used to both establish and quantify differences between categories of the groups of variables under study. In addition, the central tendency and variability of the O3 concentration at Belisario station were exhaustively analyzed, concluding that said concentration was stable for years, highly variable for months and hours, and slightly changing between the days of the week. Additionally, according to the criteria established by the IAQ, it was shown that in Quito, the O3 concentration levels during the study period were not harmful to human health.

6.
Sensors (Basel) ; 20(11)2020 May 30.
Article in English | MEDLINE | ID: mdl-32486331

ABSTRACT

Development of contaminant detection systems in various natural and industrial environments has been favored in recent years thanks to the evolution of processors and sensors. Our group works specifically on contaminant detection systems in inland waters: immediate and continuous detection is a fundamental requirement in this type of sensing. Regarding the sensors, the proposed system is based on fluorescence, since it offers a method in which there is no contact with water, which means less wear on the components and a great saving in cleaning and maintenance. On the other hand, the spectrum processing is of great importance, since it is used both in the generation of a library of fluorescence spectra taken in the laboratory and in the continuous analysis of the samples and in the comparison algorithm for identification. The validity of the system is based on the last process that is carried out in a very short time. This article describes a system to process spectra in a more accelerated way.

7.
Sensors (Basel) ; 16(3): 293, 2016 Feb 26.
Article in English | MEDLINE | ID: mdl-26927113

ABSTRACT

This work analyzes the long-term functionality of HP (High-power) UV-LEDs (Ultraviolet Light Emitting Diodes) as the exciting light source in non-contact, continuous 24/7 real-time fluoro-sensing pollutant identification in inland water. Fluorescence is an effective alternative in the detection and identification of hydrocarbons. The HP UV-LEDs are more advantageous than classical light sources (xenon and mercury lamps) and helps in the development of a low cost, non-contact, and compact system for continuous real-time fieldwork. This work analyzes the wavelength, output optical power, and the effects of viscosity, temperature of the water pollutants, and the functional consistency for long-term HP UV-LED working operation. To accomplish the latter, an analysis of the influence of two types 365 nm HP UV-LEDs degradation under two continuous real-system working mode conditions was done, by temperature Accelerated Life Tests (ALTs). These tests estimate the mean life under continuous working conditions of 6200 h and for cycled working conditions (30 s ON & 30 s OFF) of 66,000 h, over 7 years of 24/7 operating life of hydrocarbon pollution monitoring. In addition, the durability in the face of the internal and external parameter system variations is evaluated.


Subject(s)
Hydrocarbons/isolation & purification , Ultraviolet Rays , Water Pollutants, Chemical/isolation & purification , Water/analysis , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...