Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Urology ; 182: 125-132, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37673406

ABSTRACT

OBJECTIVE: To report the impact of resection base inner layer renorrhaphy suture type on renal artery pseudoaneurysm (RAP) rate following robotic-assisted partial nephrectomy (RAPN). METHODS: Five hundred and sixty-three consecutive RAPNs performed by a single surgeon were retrospectively reviewed. Patients were classified into 3 categories: (1) No base suture, (2) monofilament barbed suture (2-0 V-Loc 180 absorbable suture, Medtronic, Minneapolis, MN), (3) polyglactin 910 (2-0 Vicryl coated suture, Ethicon Inc, Cincinnati, OH). In a secondary analysis, we evaluated suturing (Vicryl and V-Loc) vs no base suture. All patients had outer cortical renorrhaphy performed with 0-Vicryl suture utilizing the standard sliding clip technique. RESULTS: One hundred ten patients (19.5%) had V-Loc suturing, 255 patients (45.3%) had Vicryl suturing, and 198 patients (35.2%) had no base suture. Patients had a median age of 62.8years (interquartile range: 53.5-69.7) and median RENAL score was 8 (6-9). Median mass size from preoperative imaging was 3.0 cm (2.5-4.0) for V-Loc, 3.3 cm (2.5-4.2) for Vicryl, and 2.0 cm (1.8-3.0) for no base suture (P < .001). Overall, 21 patients (3.7%) developed a symptomatic postoperative RAP. The rate of RAP was 3.6% (4/110) for V-Loc, 3.9% (10/255) for 2-0 Vicryl, and 3.5% (7/198) for no base suture (P = 1.00). Similarly, the rate of RAP was 3.5% (7/198) for no base suture and 3.8% (14/365) for base suture (P = 1.00). CONCLUSION: Utilization of base suture and type of base suture used during RAPN was not predictive of postoperative RAP development.


Subject(s)
Aneurysm, False , Robotic Surgical Procedures , Humans , Middle Aged , Renal Artery/surgery , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/methods , Aneurysm, False/etiology , Aneurysm, False/surgery , Polyglactin 910 , Retrospective Studies , Nephrectomy/adverse effects , Nephrectomy/methods , Sutures/adverse effects , Suture Techniques/adverse effects
2.
Urology ; 180: 209-213, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37437611

ABSTRACT

OBJECTIVE: To compare outcomes in males given perioperative tranexamic acid (TXA) during holmium laser enucleation of the prostate (HoLEP) to a historical cohort that did not receive TXA. METHODS: Our cohort included HoLEP patients (N = 1037) from August 2018 through November 2022. Exclusion criteria included history of stroke, transient ischemic attack, or coronary stent placed within 18 months. The primary predictor was TXA during HoLEP. The primary outcome variable was a return to the operating room (RTOR) for bleeding. Secondary outcomes included catheter reinsertion, transfusion, and clotting complications. Multivariable models evaluating associations of TXA with outcomes were adjusted for potential confounders. RESULTS: In our cohort, 214/1035 had one or more complications with 81 having a Clavien-Dindo Grade of 3a or higher, 114/1037 with catheter reinsertion, 36/1037 RTOR for bleeding, and 15/1035 had a transfusion. TXA use was not associated with 30-day RTOR. 3.7% of those without TXA had a RTOR, and 3.1% of those with TXA had a RTOR (adjusted odds ratio 0.63, 95% CI 0.28-1.38, P = .25). Transfusion rates were higher for those without TXA (2.0%) compared to with (0.5%). This was statistically significant after adjustment (adjusted odds ratio 0.13, 95% CI 0.03-0.69, P = .016) and after correction for multiple testing (corrected P = .048). TXA use was not associated with catheter reinsertion or clotting complications. CONCLUSION: Routine perioperative intravenous TXA in HoLEP patients was not associated with a reduction of RTOR for bleeding, catheter reinsertion, or clotting complications. TXA was associated with decreased transfusions with a low overall event rate of 1.4%.


Subject(s)
Laser Therapy , Lasers, Solid-State , Prostatic Hyperplasia , Tranexamic Acid , Transurethral Resection of Prostate , Male , Humans , Prostate/surgery , Tranexamic Acid/adverse effects , Lasers, Solid-State/adverse effects , Prostatic Hyperplasia/surgery , Treatment Outcome , Hemorrhage/prevention & control , Hemorrhage/complications , Holmium , Laser Therapy/adverse effects
3.
P R Health Sci J ; 41(4): 247-249, 2022 12.
Article in English | MEDLINE | ID: mdl-36516213

ABSTRACT

Leiomyomas are the most common mesenchymal tumors of the urinary bladder. They account for 0.43% of all bladder tumors. Their incidence is 3 times higher in women than in men. There are approximately 250 cases described in the scientific literature, but none are of Caribbean males. The intramural location of the neoplasm described in this article was uncommon; only 7% of all the leiomyomas of the urinary bladder are found in this location. We present a case of a 65-year-old male with an intramural leiomyoma that was found incidentally during the evaluation of left lower-quadrant abdominal pain. The histopathological specimen that was taken at the time at the time of surgery showed a tumor with atypical smooth muscle cells indicative of a leiomyoma. The clinical presentation, radiographic imaging, and surgical management of this rare tumor are presented herein.


Subject(s)
Leiomyoma , Urinary Bladder Neoplasms , Male , Female , Humans , Aged , Urinary Bladder/pathology , Urinary Bladder/surgery , Leiomyoma/diagnosis , Leiomyoma/surgery , Leiomyoma/pathology , Urinary Bladder Neoplasms/diagnosis , Urinary Bladder Neoplasms/surgery , Abdominal Pain , Caribbean Region
4.
Int J Urol ; 29(12): 1439-1444, 2022 12.
Article in English | MEDLINE | ID: mdl-36000924

ABSTRACT

OBJECTIVE: To validate a new baseline estimated glomerular filtration rate (NB-GFR) formula in a cohort of robotic-assisted partial nephrectomies (RAPN). METHODS: NB-GFR = 35 + preoperative GFR (× 0.65) - 18 (if radical nephrectomy) - age (× 0.25) + 3 (if tumor size >7 cm) - 2 (if diabetes). NB-GFR was calculated in 464 consecutive RAPN from a single surgeon cohort. 143 patients were excluded secondary to insufficient eGFR follow up. We analyzed NB-GFR accuracy utilizing the last observed eGFR 3-12 months post RAPN. Categorical variables were summarized with the frequency and percentage of patients. Numerical variables were summarized with the median, 25th percentile, and 75th percentile. RESULTS: The mean difference between observed and predicted NB-GFR was 4.6 ml/min/1.73m2 (95% CI -6.9 to 16.1 ml/min/1.73m2 ). There was a pattern of higher observed NB-GFRs being underestimated by the NB-GFR equation while lower observed NB-GFRs were overestimated by the NB-GFR equation. The NB-GFR formula had a high level of accuracy with 98.8% of predicted NB-GFRs falling within 30% of the observed NB-GFR (95% CI 86.8% to 99.5%). The median and interquartile range of the difference between observed and predicted NB-GFR was 3.9 ml/min/1.73m2 (IQR 0.7 to 8.2 ml/min/1.73m2 ). The sensitivity, specificity, positive predictive value, and negative predictive value for the ability of predicted NB-GFR to identify those with an observed NB-GFR <60 ml/min/1.73m2 after RAPN was 98%, 92%, 88%, and 99%, respectively. CONCLUSION: The NB-GFR equation developed with partial and radical nephrectomy cohorts is accurate in predicting post-operative eGFR 3-12 months following RAPN.


Subject(s)
Kidney Neoplasms , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/adverse effects , Kidney Neoplasms/surgery , Retrospective Studies , Treatment Outcome , Nephrectomy/adverse effects , Glomerular Filtration Rate , Kidney/diagnostic imaging , Kidney/surgery , Kidney/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...