Heart Rhythm O2 ; 5(6): 403-416, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38984358

ABSTRACT

Proactive esophageal cooling for the purpose of reducing the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation procedures is increasingly being used and has been Food and Drug Administration cleared as a protective strategy during left atrial RF ablation for the treatment of atrial fibrillation. In this review, we examine the evidence supporting the use of proactive esophageal cooling and the potential mechanisms of action that reduce the likelihood of atrioesophageal fistula (AEF) formation. Although the pathophysiology behind AEF formation after thermal injury from RF ablation is not well studied, a robust literature on fistula formation in other conditions (eg, Crohn disease, cancer, and trauma) exists and the relationship to AEF formation is investigated in this review. Likewise, we examine the abundant data in the surgical literature on burn and thermal injury progression as well as the acute and chronic mitigating effects of cooling. We discuss the relationship of these data and maladaptive healing mechanisms to the well-recognized postablation pathophysiological effects after RF ablation. Finally, we review additional important considerations such as patient selection, clinical workflow, and implementation strategies for proactive esophageal cooling.

2.
PLoS One ; 19(6): e0300445, 2024.
Article in English | MEDLINE | ID: mdl-38924000

ABSTRACT

The study investigates the efficacy of a bioinspired Particle Swarm Optimization (PSO) approach for PID controller tuning in Radiofrequency Ablation (RFA) for liver tumors. Ex-vivo experiments were conducted, yielding a 9th order continuous-time transfer function. PSO was applied to optimize PID parameters, achieving outstanding simulation results: 0.605% overshoot, 0.314 seconds rise time, and 2.87 seconds settling time for a unit step input. Statistical analysis of 19 simulations revealed PID gains: Kp (mean: 5.86, variance: 4.22, standard deviation: 2.05), Ki (mean: 9.89, variance: 0.048, standard deviation: 0.22), Kd (mean: 0.57, variance: 0.021, standard deviation: 0.14) and ANOVA analysis for the 19 experiments yielded a p-value ≪ 0.05. The bioinspired PSO-based PID controller demonstrated remarkable potential in mitigating roll-off effects during RFA, reducing the risk of incomplete tumor ablation. These findings have significant implications for improving clinical outcomes in hepatocellular carcinoma management, including reduced recurrence rates and minimized collateral damage. The PSO-based PID tuning strategy offers a practical solution to enhance RFA effectiveness, contributing to the advancement of radiofrequency ablation techniques.


Subject(s)
Liver Neoplasms , Radiofrequency Ablation , Liver Neoplasms/surgery , Radiofrequency Ablation/methods , Humans , Carcinoma, Hepatocellular/surgery , Animals , Algorithms , Computer Simulation , Catheter Ablation/methods
3.
Med Biol Eng Comput ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38822997

ABSTRACT

Cardiac catheter ablation requires an adequate contact between myocardium and catheter tip. Our aim was to quantify the relationship between the contact force (CF) and the resulting mechanical deformation induced by the catheter tip using an ex vivo model and computational modeling. The catheter tip was inserted perpendicularly into porcine heart samples. CF values ranged from 10 to 80 g. The computer model was built to simulate the same experimental conditions, and it considered a 3-parameter Mooney-Rivlin model based on hyper-elastic material. We found a strong correlation between the CF and insertion depth (ID) (R2 = 0.96, P < 0.001), from 0.7 ± 0.3 mm at 10 g to 6.9 ± 0.1 mm at 80 g. Since the surface deformation was asymmetrical, two transversal diameters (minor and major) were identified. Both diameters were strongly correlated with CF (R2 ≥ 0.95), from 4.0 ± 0.4 mm at 20 g to 10.3 ± 0.0 mm at 80 g (minor), and from 6.4 ± 0.7 mm at 20 g to 16.7 ± 0.1 mm at 80 g (major). An optimal fit between computer and experimental results was achieved, with a prediction error of 0.74 and 0.86 mm for insertion depth and mean surface diameter, respectively.

4.
Comput Biol Med ; 174: 108490, 2024 May.
Article in English | MEDLINE | ID: mdl-38642490

ABSTRACT

BACKGROUND: Pulsed Field Ablation (PFA) has recently been proposed as a non-thermal energy to treat atrial fibrillation by selective ablation of ganglionated plexi (GP) embedded in epicardial fat. While some of PFA-technologies use an endocardial approach, others use epicardial access with promising pre-clinical results. However, as each technology uses a different and sometimes proprietary pulse application protocol, the comparation between endocardial vs. epicardial approach is almost impossible in experimental terms. For this reason, our study, based on a computational model, allows a direct comparison of electric field distribution and thermal-side effects of both approaches under equal conditions in terms of electrode design, pulse protocol and anatomical characteristics of the tissues involved. METHODS: 2D computational models with axial symmetry were built for endocardial and epicardial approaches. Atrial (1.5-2.5 mm) and fat (1-5 mm) thicknesses were varied to simulate a representative sample of what happens during PFA ablation for different applied voltage values (1000, 1500 and 2000 V) and number of pulses (30 and 50). RESULTS: The epicardial approach was superior for capturing greater volumes of fat when the applied voltage was increased: 231 mm3/kV with the epicardial approach vs. 182 mm3/kV with the endocardial approach. In relation to collateral damage to the myocardium, the epicardial approach considerably spares the myocardium, unlike what happens with the endocardial approach. Although the epicardial approach caused much more thermal damage in the fat, there is not a significant difference between the approaches in terms of size of thermal damage in the myocardium. CONCLUSIONS: Our results suggest that epicardial PFA ablation of GPs is more effective than an endocardial approach. The proximity and directionality of the electric field deposited using an epicardial approach are key to ensuring that higher electric field strengths and increased temperatures are obtained within the epicardial fat, thus contributing to selective ablation of the GPs with minimal myocardial damage.


Subject(s)
Atrial Fibrillation , Computer Simulation , Endocardium , Models, Cardiovascular , Pericardium , Endocardium/physiopathology , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/methods
5.
Lasers Surg Med ; 56(4): 392-403, 2024 04.
Article in English | MEDLINE | ID: mdl-38436122

ABSTRACT

BACKGROUND AND OBJECTIVES: Laser ablation is increasingly used to treat atrial fibrillation (AF). However, atrioesophageal injury remains a potentially serious complication. While proactive esophageal cooling (PEC) reduces esophageal injury during radiofrequency ablation, the effects of PEC during laser ablation have not previously been determined. We aimed to evaluate the protective effects of PEC during laser ablation of AF by means of a theoretical study based on computer modeling. METHODS: Three-dimensional mathematical models were built for 20 different cases including a fragment of atrial wall (myocardium), epicardial fat (adipose tissue), connective tissue, and esophageal wall. The esophagus was considered with and without PEC. Laser-tissue interaction was modeled using Beer-Lambert's law, Pennes' Bioheat equation was used to compute the resultant heating, and the Arrhenius equation was used to estimate the fraction of tissue damage (FOD), assuming a threshold of 63% to assess induced necrosis. We modeled laser irradiation power of 8.5 W over 20 s. Thermal simulations extended up to 250 s to account for thermal latency. RESULTS: PEC significantly altered the temperature distribution around the cooling device, resulting in lower temperatures (around 22°C less in the esophagus and 9°C in the atrial wall) compared to the case without PEC. This thermal reduction translated into the absence of transmural lesions in the esophagus. The esophagus was thermally damaged only in the cases without PEC and with a distance equal to or shorter than 3.5 mm between the esophagus and endocardium (inner boundary of the atrial wall). Furthermore, PEC demonstrated minimal impact on the lesion created across the atrial wall, either in terms of maximum temperature or FOD. CONCLUSIONS: PEC reduces the potential for esophageal injury without degrading the intended cardiac lesions for a variety of different tissue thicknesses. Thermal latency may influence lesion formation during laser ablation and may play a part in any collateral damage.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Laser Therapy , Humans , Esophagus/surgery , Esophagus/injuries , Esophagus/pathology , Heart Atria/surgery , Atrial Fibrillation/surgery , Lasers , Computers , Catheter Ablation/methods
6.
PLoS One ; 18(11): e0287614, 2023.
Article in English | MEDLINE | ID: mdl-37917621

ABSTRACT

Even though the preliminary experimental data suggests that cardiac Pulsed Field Ablation (PFA) could be superior to radiofrequency ablation (RFA) in terms of being able to ablate the viable myocardium separated from the catheter by collagen and fat, as yet there is no formal physical-based analysis that describes the process by which fat can affect the electric field distribution. Our objective was thus to determine the electrical impact of intramyocardial fat during PFA by means of computer modeling. Computer models were built considering a PFA 3.5-mm blunt-tip catheter in contact with a 7-mm ventricular wall (with and without a scar) and a 2-mm epicardial fat layer. High voltage was set to obtain delivered currents of 19, 22 and 25 A. An electric field value of 1000 V/cm was considered as the lethal threshold. We found that the presence of fibrotic tissue in the scar seems to have a similar impact on the electric field distribution and lesion size to that of healthy myocardium only. However, intramyocardial fat considerably alters the electrical field distribution and the resulting lesion shape. The electric field tends to peak in zones with fat, even away from the ablation electrode, so that 'cold points' (i.e. low electric fields) appear around the fat at the current entry and exit points, while 'hot points' (high electric fields) occur in the lateral areas of the fat zones. The results show that intramyocardial fat can alter the electric field distribution and lesion size during PFA due to its much lower electrical conductivity than that of myocardium and fibrotic tissue.


Subject(s)
Catheter Ablation , Cicatrix , Humans , Cicatrix/pathology , Catheter Ablation/methods , Computer Simulation , Pericardium/pathology , Fibrosis , Computers
7.
J Cardiovasc Dev Dis ; 10(6)2023 May 29.
Article in English | MEDLINE | ID: mdl-37367403

ABSTRACT

Atrial fibrillation (AF) is the most common cardiac arrhythmia affecting millions of people worldwide. The cardiac autonomic nervous system (ANS) is widely recognized as playing a key role in both the initiation and propagation of AF. This paper reviews the background and development of a unique cardioneuroablation technique for the modulation of the cardiac ANS as a potential treatment for AF. The treatment uses pulsed electric field energy to selectively electroporate ANS structures on the epicardial surface of the heart. Insights from in vitro studies and electric field models are presented as well as data from both pre-clinical and early clinical studies.

8.
Int J Hyperthermia ; 40(1): 2163310, 2023.
Article in English | MEDLINE | ID: mdl-36592987

ABSTRACT

PURPOSE: While radiofrequency catheter ablation (RFCA) creates a lesion consisting of the tissue points subjected to lethal heating, the sublethal heating (SH) undergone by the surrounding tissue can cause transient electrophysiological block. The size of the zone of heat-induced transient block (HiTB) has not been quantified to date. Our objective was to use computer modeling to provide an initial estimate. METHODS AND MATERIALS: We used previous experimental data together with the Arrhenius damage index (Ω) to fix the Ω values that delineate this zone: a lower limit of 0.1-0.4 and upper limit of 1.0 (lesion boundary). An RFCA computer model was used with different power-duration settings, catheter positions and electrode insertion depths, together with dispersion of the tissue's electrical and thermal characteristics. RESULTS: The HiTB zone extends in depth to a minimum and maximum distance of 0.5 mm and 2 mm beyond the lesion limit, respectively, while its maximum width varies with the energy delivered, extending to a minimum of 0.6 mm and a maximum of 2.5 mm beyond the lesion, reaching 3.5 mm when high energy settings are used (25 W-20s, 500 J). The dispersion of the tissue's thermal and electrical characteristics affects the size of the HiTB zone by ±0.3 mm in depth and ±0.5 mm in maximum width. CONCLUSIONS: Our results suggest that the size of the zone of heat-induced transient block during RFCA could extend beyond the lesion limit by a maximum of 2 mm in depth and approximately 2.5 mm in width.


Subject(s)
Catheter Ablation , Hot Temperature , Heart , Catheter Ablation/adverse effects , Catheter Ablation/methods , Computer Simulation
9.
J Interv Card Electrophysiol ; 66(5): 1085-1093, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35796934

ABSTRACT

BACKGROUND: Pilot clinical studies suggest that very high power-very short duration (vHPvSD, 90 W/4 s, 360 J energy) is a feasible and safe technique for ablation of atrial fibrillation (AF), compared with standard applications using moderate power-moderate duration (30 W/30 s, 900 J energy). However, it is unclear whether alternate power and duration settings for the delivery of the same total energy would result in similar lesion formation. This study compares temperature dynamics and lesion size at different power-duration settings for the delivery of equivalent total energy (360 J). METHODS: An in silico model of radiofrequency (RF) ablation was created using the Arrhenius function to estimate lesion size under different power-duration settings with energy balanced at 360 J: 30 W/12 s (MPSD), 50 W/7.2 s (HPSD), and 90 W/4 s (vHPvSD). Three catheter orientations were considered: parallel, 45°, and perpendicular. RESULTS: In homogenous tissue, vHPvSD and HPSD produced similar size lesions independent of catheter orientation, both of which were slightly larger than MPSD (lesion size 0.1 mm deeper, ~ 0.7 mm wider, and ~ 25 mm3 larger volume). When considering heterogeneous tissue, these differences were smaller. Tissue reached higher absolute temperature with vHPvSD and HPSD (5-8 °C higher), which might increase risk of collateral tissue injury or steam pops. CONCLUSION: Ablation for AF using MPSD or HPSD may be a feasible alternative to vHPvSD ablation given similar size lesions with similar total energy delivery (360 J). Lower absolute tissue temperature and slower heating may reduce risk of collateral tissue injury and steam pops associated with vHPvSD and longer applications using moderate power.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Humans , Steam , Catheter Ablation/methods , Radiofrequency Ablation/methods , Atrial Fibrillation/surgery , Computer Simulation , Pulmonary Veins/surgery , Treatment Outcome
10.
Bioengineering (Basel) ; 11(1)2023 Dec 24.
Article in English | MEDLINE | ID: mdl-38247895

ABSTRACT

Epicardial pulsed field ablation (PFA) of ganglionated plexi (GPs) is being explored as a potential treatment for atrial fibrillation. Initial work using open-chest access with a monopolar ablation device has been completed. This study describes the early development work for a device that can be used with subxiphoid access and deliver bipolar ablation pulses. Electric field computational models have been used for the initial guidance on pulse parameters. An in vivo assessment of these ablation parameters has been performed in an open-chest canine study, while subxiphoid access and navigation of the device has been demonstrated in a porcine model. Results from this acute study have demonstrated the promising potential of this approach.

11.
Bioengineering (Basel) ; 9(12)2022 Nov 27.
Article in English | MEDLINE | ID: mdl-36550937

ABSTRACT

BACKGROUND AND OBJECTIVES: Pulsed Electric Field (PEF) ablation has been proposed as a non-thermal energy to treat atrial fibrillation (AF) by epicardial ablation of ganglionated plexi (GP), which are embedded within epicardial fat. Our objective was to study the distribution of the electric field through the involved tissues (fat, GPs, myocardium and blood) during epicardial PEF ablation. METHODS: A two-dimensional model was built considering different tissue layers below the ablation device which consists of an irrigated electrode. The 1000 V/cm threshold was used to estimate the 'PEF-zone'. RESULTS: The PEF-zone was almost 100% circumscribed in the epicardial fat layer, with very little incidence in the myocardium. The presence of the saline on the epicardial fat causes the PEF-zone to spread laterally around the electrode from ~5 mm to ~15 mm, relatively independently of how embedded the electrode is in the saline layer. For a saline layer well spread over the tissue surface and an electrode fully embedded in the saline layer, the PEF-zone width decreases as the fat layer thickens: from ~15 mm for fat thickness of 1 and 2 mm, down to ~10 mm for fat thickness of 5 mm. The presence of a GP in the center of the fat layer hardly affects the size of the PEF-zone, but significantly alters the distribution of the electric field around the GP, resulting in progressively lower values than in the surrounding adipose tissue as the fat layer thickness increased. CONCLUSIONS: Our results suggest how some procedural (irrigation) and anatomical parameters (fat thicknesses and presence of GPs) could be relevant in terms of the size of the tissue area affected by pulsed field ablation.

12.
J Cardiovasc Dev Dis ; 9(12)2022 Dec 14.
Article in English | MEDLINE | ID: mdl-36547455

ABSTRACT

Background: Pulsed Electric Field (PEF) ablation has been recently proposed to ablate cardiac ganglionic plexi (GP) aimed to treat atrial fibrillation. The effect of metal intracoronary stents in the vicinity of the ablation electrode has not been yet assessed. Methods: A 2D numerical model was developed accounting for the different tissues involved in PEF ablation with an irrigated ablation device. A coronary artery (with and without a metal intracoronary stent) was considered near the ablation source (0.25 and 1 mm separation). The 1000 V/cm threshold was used to estimate the 'PEF-zone'. Results: The presence of the coronary artery (with or without stent) distorts the E-field distribution, creating hot spots (higher E-field values) in the front and rear of the artery, and cold spots (lower E-field values) on the sides of the artery. The value of the E-field inside the coronary artery is very low (~200 V/cm), and almost zero with a metal stent. Despite this distortion, the PEF-zone contour is almost identical with and without artery/stent, remaining almost completely confined within the fat layer in any case. The mentioned hot spots of E-field translate into a moderate temperature increase (<48 °C) in the area between the artery and electrode. These thermal side effects are similar for pulse intervals of 10 and 100 µs. Conclusions: The presence of a metal intracoronary stent near the ablation device during PEF ablation simply 'amplifies' the E-field distortion already caused by the presence of the vessel. This distortion may involve moderate heating (<48 °C) in the tissue between the artery and ablation electrode without associated thermal damage.

14.
Bioengineering (Basel) ; 9(7)2022 Jul 19.
Article in English | MEDLINE | ID: mdl-35877380

ABSTRACT

Beating heart (BH) and thigh muscle (TM) are two pre-clinical models aimed at studying the lesion sizes created by radiofrequency (RF) catheters in cardiac ablation. Previous experimental results have shown that thermal lesions created in the TM are slightly bigger than in the BH. Our objective was to use in-silico modeling to elucidate some of the causes of this difference. In-silico RF ablation models were created using the Arrhenius function to estimate lesion size under different energy settings (25 W/20 s, 50 W/6 s and 90 W/4 s) and parallel, 45° and perpendicular catheter positions. The models consisted of homogeneous tissue: myocardium in the BH model and striated muscle in the TM model. The computer results showed that the lesion sizes were generally bigger in the TM model and the differences depended on the energy setting, with hardly any differences at 90 W/4 s but with differences of 1 mm in depth and 1.5 m in width at 25 W/20 s. The higher electrical conductivity of striated muscle (0.446 S/m) than that of the myocardium (0.281 S/m) is possibly one of the causes of the higher percentage of RF energy delivered to the tissue in the TM model, with differences between models of 2-5% at 90 W/4 s, ~9% at 50 W/6 s and ~10% at 25 W/20 s. Proximity to the air-blood interface (just 2 cm from the tissue surface) artificially created in the TM model to emulate the cardiac cavity had little effect on lesion size. In conclusion, the TM-based experimental model creates fairly similar-sized lesions to the BH model, especially in high-power short-duration ablations (50 W/6 s and 90 W/4 s). Our computer results suggest that the higher electrical conductivity of striated muscle could be one of the causes of the slightly larger lesions in the TM model.

15.
Comput Methods Programs Biomed ; 221: 106886, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35597202

ABSTRACT

BACKGROUND AND OBJECTIVES: Pulsed Electric Field (PEF) ablation has been proposed as a non-thermal energy to treat atrial fibrillation (AF) by ablation of ganglionated plexi using the epicardial approach. The electric field distribution at the target site (heart) and its surroundings has not yet been assessed previously, using epicardial ablation technique. Our objective was to develop computational models, incorporating the real anatomy of the heart and the patient's torso, to assess the electric field distribution when applying epicardial monopolar PEF. METHODS: A novel 3D realistic full torso model was built with the multi-electrode ablation device placed on the epicardium and a dispersive pad on the patient's back to evaluate the electric field distribution. The 400 V/cm isoline was used to estimate the 'PEF-zone'. A 3D limited-domain model was also built including only the region of interest around the ablation device to assess its validity in comparison with the full torso model. RESULTS: The electrical field is mainly limited to the target site (PEF-zone with lengths of 25.79 to 29.00 mm, depths of 5.98-7.02 mm and maximum widths of 8.75-10.57 mm) and is practically negligible in adjacent organs (<30 V/cm and <36 V/cm in oesophagus and lungs, respectively). The electrical currents ranged from 3.67 A to 7.44 A. The 3D limited-domain model provided a similar electric field distribution to those obtained from the 3D full torso models (differences < 0.5 mm in PEF-zone depth). CONCLUSIONS: Computational results suggest that PEF-zone is very focused around the ablation catheter. Limited-domain models offer similar results in terms of PEF-zone size, reducing the complexity of the modelling.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Catheter Ablation/methods , Computer Simulation , Humans , Pericardium/surgery , Torso/surgery
16.
Comput Methods Programs Biomed ; 220: 106817, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35468542

ABSTRACT

BACKGROUND AND OBJECTIVES: To study temperature distribution and lesion size during two repeated radiofrequency (RF) pulses applied at the same point in the context of RF cardiac ablation (RFCA). METHODS: An in-silico RFCA model accounting for reversible and irreversible changes in myocardium electrical properties due to RF-induced heating. Arrhenius damage model to estimate lesion size during the application of two 20 W pulses at intervals (INT) of from 5 to 70 s. We considered two pulse durations: 20 s and 30 s. RESULTS: INT has a significant effect on lesion size and maximum tissue temperature (TMAX). The shorter the INT the greater the increase in lesion size after the second pulse but also the greater the TMAX. If the second pulse is applied almost immediately (INT=5 s), depth increases 1.4 mm and 1.5 mm for pulses of 20 s and 30 s, respectively. If INT is longer than 30 s it increases 1.1 mm and 1.3 mm for pulses of 20 s and 30 s, respectively. While a single 20 s pulse causes TMAX=79 ºC, a second pulse produces values of from 92 to 96 ºC (the higher the temperature the shorter the INT). For 30 s pulses, TMAX=93 ºC for a single pulse, and varied from 98 to 104 ºC for a second pulse. CONCLUSIONS: Applying a second RF pulse at the same ablation site increases lesion depth by 1 - 1.5 mm more than a single pulse and could lead to higher temperatures (up to 17 ºC). Both lesion depth and maximum tissue temperature increased at shorter inter-pulse intervals, which could cause clinical complications from overheating such as steam pops.


Subject(s)
Cardiac Catheters , Catheter Ablation , Catheters , Computer Simulation , Heart
17.
Comput Biol Med ; 144: 105346, 2022 05.
Article in English | MEDLINE | ID: mdl-35240375

ABSTRACT

BACKGROUND: The state of the art in computer modeling of radiofrequency catheter ablation (RFCA) only considers a static situation, i.e. it ignores ablation electrode displacements induced by tissue movement due to heartbeats. This feature is theoretically required, since heartbeat-induced changes in contact force can be detected during this clinical procedure. METHODS: We built a 2D RFCA model coupling electrical, thermal and mechanical problems and simulated a standard energy setting (25 W-30 s). The mechanical interaction between the ablation electrode and tissue was dynamically modeled to reproduce heartbeat-induced changes in the electrode insertion depth from 0.86 to 2.05 mm, which corresponded with contact forces between 10 and 30 g when cardiac tissue was modeled by a hyperelastic Neo-Hookean model with a Young's modulus of 75 kPa and Poisson's ratio of 0.49. RESULTS: The lesion size computed in the dynamic case was 6.04 mm deep, 9.48 mm maximum width and 6.98 mm surface width, which is within the range of previous experimental results based on a beating heart for a similar energy setting and contact force. The lesion size was practically identical (less than 0.04 mm difference) in the static case with the electrode inserted to an average depth of 1.46 mm (equivalent to 20 g contact force). CONCLUSIONS: The RFCA model including heartbeat-induced electrode displacement predicts lesion depth reasonably well compared to previous experimental results based on a beating heart model.


Subject(s)
Catheter Ablation , Catheter Ablation/methods , Computer Simulation , Computers , Electrodes , Heart Rate
18.
Comput Methods Programs Biomed ; 214: 106546, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34844766

ABSTRACT

This review begins with a rationale of the importance of theoretical, mathematical and computational models for radiofrequency (RF) catheter ablation (RFCA). We then describe the historical context in which each model was developed, its contribution to the knowledge of the physics of RFCA and its implications for clinical practice. Next, we review the computer modeling studies intended to improve our knowledge of the biophysics of RFCA and those intended to explore new technologies. We describe the most important technical details of the implementation of mathematical models, including governing equations, tissue properties, boundary conditions, etc. We discuss the utility of lumped element models, which despite their simplicity are widely used by clinical researchers to provide a physical explanation of how RF power is absorbed in different tissues. Computer model verification and validation are also discussed in the context of RFCA. The article ends with a section on the current limitations, i.e. aspects not yet included in state-of-the-art RFCA computer modeling and on future work aimed at covering the current gaps.


Subject(s)
Catheter Ablation , Bioengineering , Biomedical Engineering , Computer Simulation , Computers , Treatment Outcome
19.
J Cardiovasc Electrophysiol ; 33(2): 220-230, 2022 02.
Article in English | MEDLINE | ID: mdl-34855276

ABSTRACT

OBJECTIVE: To model the evolution of peak temperature and volume of damaged esophagus during and after radiofrequency (RF) ablation using low power-moderate duration (LPMD) versus high power-short duration (HPSD) or very high power-very short duration (VHPVSD) settings. METHODS: An in silico simulation model of RF ablation accounting for left atrial wall thickness, nearby organs and tissues, as well as catheter contact force. The model used the Arrhenius equation to derive a thermal damage model and estimate the volume of esophageal damage over time during and after RF application under conditions of LPMD (30 W, 20 s), HPSD (50 W, 6 s), and VHPVSD (90 W, 4 s). RESULTS: There was a close correlation between maximum peak temperature after RF application and volume of esophageal damage, with highest correlation (R2 = 0.97) and highest volume of esophageal injury in the LPMD group. A greater increase in peak temperature and greater relative increase in esophageal injury volume in the HPSD (240%) and VHPSD (270%) simulations occurred after RF termination. Increased endocardial to esophageal thickness was associated with a longer time to maximum peak temperature (R2 > 0.92), especially in the HPSD/VHPVSD simulations, and no esophageal injury was seen when the distances were >4.5 mm for LPMD or >3.5 mm for HPSD. CONCLUSION: LPMD is associated with a larger total volume of esophageal damage due to the greater total RF energy delivery. HPSD and VHPVSD shows significant thermal latency (resulting from conductive tissue heating after RF termination), suggesting a requirement for fewer esophageal temperature cutoffs during ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Body Temperature , Catheter Ablation/adverse effects , Humans , Pulmonary Veins/surgery , Temperature
20.
Int J Hyperthermia ; 38(1): 582-592, 2021.
Article in English | MEDLINE | ID: mdl-33847211

ABSTRACT

PURPOSE: While the standard setting during radiofrequency catheter ablation (RFCA) consists of applying low power for long times, a new setting based on high power and short duration (HPSD) has recently been suggested as safer and more effective. Our aim was to compare the electrical and thermal performance of standard vs. HPSD settings, especially to assess the effect of the catheter orientation. METHODS: A 3D computational model was built based on a coupled electric-thermal-flow problem. Standard (20 W-45 s and 30 W-30 s) and HPSD settings (70 W-7 s and 90 W-4 s) were compared. Since the model only included a cardiac tissue fragment, the power values were adjusted to 80% of the clinical values (15, 23, 53 and 69 W). Three catheter-tissue orientations were considered (90°, 45° and 0°). Thermal lesions were assessed by the Arrhenius equation. Safety was assessed by checking the occurrence of steam pops (100 °C in tissue) and thrombus formation (80 °C in blood). RESULTS: The computed thermal lesions were in close agreement with the experimental data in the literature, in particular with in vivo studies. HPSD created shallower and wider lesions than standard settings, especially with the catheter at 45°. Steam pops occurred earlier with HPSD, regardless of catheter orientation. CONCLUSION: HPSD seems to be more effective in cases that need shallow and extensive lesions, especially when the catheter is at 0° or at 45°, as used in pulmonary vein isolation.


Subject(s)
Catheter Ablation , Pulmonary Veins , Computer Simulation , Pulmonary Veins/surgery , Time Factors