Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Surg Res ; 18(1): 768, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37817247

ABSTRACT

INTRODUCTION: Miserable malalignment syndrome is a complex torsional lower limb deformity with limited consensus on surgical treatment. We present the outcome of de-rotation of the tibia alone using an external fixator. METHODS: Fifteen patients (22 segments) were operated on between 2012 and 2020; 13 presented with anterior knee pain, and two presented with out-toeing. Gait analysis was done in nine patients, and CT scan rotational profile, including tibial tubercle-trochlear groove distance, femoral version, and tibial torsion, were calculated. Kujala knee pain score and visual analogue pain score (VAS) were recorded. All underwent infra-tubercular osteotomy of the tibia and midshaft osteotmy of the fibula and application of a hexapod circular frame to gradually internally rotate the tibia until the foot aligned with the patella. RESULTS: There was no preoperative clinical or radiographic evidence for patellar instability, femoral anteversion 30° (21°-54°), and external tibial torsion 50° (37-70). The mean age at surgery was 21 years (12-37) with a mean follow-up of 20 months (9-83). All osteotomies healed, and the frames were removed at a mean of 111 days (80-168). The mean VAS score improved from 8(5-9) to 1(0-4) postoperatively (P < 0.001). The mean Kujala knee pain score increased from 53 (30-75) to 92 (54-100) postoperatively (P < 0.001). The mean preoperative foot progression angle (FPA) was 37° (20°-50°), with 13 postoperatively walking with neutral FPA. One patient walked with symmetrical + 10° and the other with - 5° FPA. All patients reported relief of knee pain and were satisfied with the alignment. CONCLUSION: Gradual correction of severe external tibia torsion with a hexapod external fixator and an infra-tubercle tibial osteotomy could provide an optimum method to eliminate knee pain and improve limb alignment in miserable malalignment syndrome.


Subject(s)
Joint Instability , Patellofemoral Joint , Humans , Child , Adolescent , Young Adult , Adult , Joint Instability/surgery , Patellofemoral Joint/surgery , Retrospective Studies , Knee Joint/diagnostic imaging , Knee Joint/surgery , Tibia/diagnostic imaging , Tibia/surgery , Lower Extremity , Osteotomy/methods , Syndrome
2.
Bone Jt Open ; 2(8): 599-610, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34352183

ABSTRACT

AIMS: The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. METHODS: We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions. RESULTS: All nails were removed at the end of treatment, having achieved their intended lengthening (20 mm to 65 mm) and after regenerate consolidation. All nails had evidence of corrosion localized to the screw holes and the extendable junctions; corrosion was graded as moderate at the junction of one nail and severe at the junctions of five nails. EDS analysis showed surface deposits to be chromium rich. Plain radiographs showed cortical thickening and osteolysis around the junction of six nails, corresponding to the same nails with moderate - severe junction corrosion. CONCLUSION: We found, in fully united bones, evidence of cortical thickening and osteolysis that appeared to be associated with corrosion at the extendable junction; when corrosion was present, cortical thickening was adjacent to this junction. Further work, with greater numbers of retrievals, is required to fully understand this association between corrosion and bony changes, and the influencing surgeon, implant, and patient factors involved. Cite this article: Bone Jt Open 2021;2(8):599-610.

3.
Bone Joint J ; 103-B(6): 1168-1172, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34058877

ABSTRACT

AIMS: The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device. METHODS: This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies. RESULTS: At the time of reporting, eight patients (13 implants) had completed lengthening. Osteolysis and periosteal reaction at the junction of the telescopic nail was evident in nine implants. Five patients experienced localized pain and swelling. Macroscopic appearances following retrieval were consistent with corrosion at the telescopic junction. Tissue histology was consistent with effects of focal metallic wear debris. CONCLUSION: From our early experience with this implant we have found the process of lengthening to be accurate and reliable with good regenerate formation and consolidation. Proposed advantages of early load bearing and the ability for bilateral lengthening are promising. We have, however, encountered concerning clinical and radiological findings in several patients. We have elected to discontinue its use to allow further investigation into the retrieved implants and patient outcomes from users internationally. Cite this article: Bone Joint J 2021;103-B(6):1168-1172.


Subject(s)
Bone Lengthening/instrumentation , Bone Nails , Leg Length Inequality/surgery , Adolescent , Adult , Aged , Device Removal , Female , Femur/diagnostic imaging , Femur/surgery , Humans , Leg Length Inequality/diagnostic imaging , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Tibia/diagnostic imaging , Tibia/surgery
4.
Strategies Trauma Limb Reconstr ; 15(2): 98-105, 2020.
Article in English | MEDLINE | ID: mdl-33505526

ABSTRACT

Limb lengthening by distraction osteogenesis is an accepted orthopaedic surgical technique. The Precice intramedullary lengthening system is the most recent innovation in limb lengthening. Early results have been favourable in femoral lengthening but there is little reported on the outcome in tibial lengthening. The aim of this study is to present our early results of Precice tibial lengthening, and the stepwise evolution of our surgical technique. MATERIALS AND METHODS: A case series of 17 consecutive tibial lengthenings were prospectively analysed. Healing index, length achieved, range of motion, and complications were recorded. The initial cases followed the recommended surgical technique. Progressive regenerate deformity during lengthening required changes to the surgical method. RESULTS: No cases were lost to follow-up. All the nails lengthened at the desired rate. There were no complications of infection or poor regenerate formation. Progressive valgus and procurvatum was prevented in later cases by the positioning of Poller blocking screws at the time of nail insertion. CONCLUSION: The tibial Precice nail is successful in obtaining length and good regenerate formation. The recommended technique was insufficient to control the deforming forces from the lower limb muscle compartments during lengthening. We therefore recommend the addition of multiple blocking screws in an amended technique. HOW TO CITE THIS ARTICLE: Wright SE, Goodier WD, Calder P. Regenerate Deformity with the Precice Tibial Nail. Strategies Trauma Limb Reconstr 2020;15(2):98-105.

SELECTION OF CITATIONS
SEARCH DETAIL
...