Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Sustain Chem Eng ; 10(7): 2388-2396, 2022 Feb 21.
Article in English | MEDLINE | ID: mdl-35223215

ABSTRACT

Electrochemical continuous-flow reactors offer a great opportunity for enhanced and sustainable chemical syntheses. Here, we present a novel application of electrochemical continuous-flow oscillatory baffled reactors (ECOBRs) that combines advanced mixing features with electrochemical transformations to enable efficient electrochemical oxidations under continuous flow at a millimeter distance between electrodes. Different additive manufacturing techniques have been employed to rapidly fabricate reactors. The electrochemical oxidation of NADH, a very sensitive substrate key for the regeneration of enzymes in biocatalytic transformations, has been employed as a benchmark reaction. The oscillatory conditions improved bulk mixing, facilitating the contact of reagents to electrodes. Under oscillatory conditions, the ECOBR demonstrated improved performance in the electrochemical oxidation of NADH, which is attributed to improved mass transfer associated with the oscillatory regime.

2.
Beilstein J Org Chem ; 13: 111-119, 2017.
Article in English | MEDLINE | ID: mdl-28228852

ABSTRACT

Additive manufacturing or '3D printing' is being developed as a novel manufacturing process for the production of bespoke micro- and milliscale fluidic devices. When coupled with online monitoring and optimisation software, this offers an advanced, customised method for performing automated chemical synthesis. This paper reports the use of two additive manufacturing processes, stereolithography and selective laser melting, to create multifunctional fluidic devices with embedded reaction monitoring capability. The selectively laser melted parts are the first published examples of multifunctional 3D printed metal fluidic devices. These devices allow high temperature and pressure chemistry to be performed in solvent systems destructive to the majority of devices manufactured via stereolithography, polymer jetting and fused deposition modelling processes previously utilised for this application. These devices were integrated with commercially available flow chemistry, chromatographic and spectroscopic analysis equipment, allowing automated online and inline optimisation of the reaction medium. This set-up allowed the optimisation of two reactions, a ketone functional group interconversion and a fused polycyclic heterocycle formation, via spectroscopic and chromatographic analysis.

3.
Mater Sci Eng C Mater Biol Appl ; 67: 294-303, 2016 Oct 01.
Article in English | MEDLINE | ID: mdl-27287125

ABSTRACT

Selective laser melting (SLM) has previously been shown to be a viable method for fabricating biomedical implants; however, the surface chemistry of SLM fabricated parts is poorly understood. In this study, X-ray photoelectron spectroscopy (XPS) was used to determine the surface chemistries of (a) SLM as-fabricated (SLM-AF) Ti6Al4V and (b) SLM fabricated and mechanically polished (SLM-MP) Ti6Al4V samples and compared with (c) traditionally manufactured (forged) and mechanically polished Ti6Al4V samples. The SLM-AF surface was observed to be porous with an average surface roughness (Ra) of 17.6±3.7µm. The surface chemistry of the SLM-AF was significantly different to the FGD-MP surface with respect to elemental distribution and their existence on the outermost surface. Sintered particles on the SLM-AF surface were observed to affect depth profiling of the sample due to a shadowing effect during argon ion sputtering. Surface heterogeneity was observed for all three surfaces; however, vanadium was witnessed only on the mechanically polished (SLM-MP and FGD-MP) surfaces. The direct and indirect 3T3 cell cytotoxicity studies revealed that the cells were viable on the SLM fabricated Ti6Al4V parts. The varied surface chemistry of the SLM-AF and SLM-MP did not influence the cell behaviour.


Subject(s)
Biomedical Technology/methods , Lasers , Titanium/pharmacology , Alloys , Animals , Cell Death/drug effects , Mice , NIH 3T3 Cells , Oxides/chemistry , Photoelectron Spectroscopy , Surface Properties
4.
Molecules ; 20(10): 19041-50, 2015 Oct 20.
Article in English | MEDLINE | ID: mdl-26492231

ABSTRACT

The thermal influence of carbon nanotubes (CNTs) on the PA12 in the laser sintering process was assessed by physical experiments and a three dimensional simulation model. It appears that, by adding the CNTs into the PA12 matrix, the thermal conductivity increased. A double ellipsoidal heat flux model was applied to input a three dimensional, continuous moving, volumetric laser heat source. The predicted three dimensional temperature distributions suggested that the laser heat was conducted wider and deeper in the PA12-CNT sample than PA12. Greater heat conduction can reduce the interspace between two successive layers, and result in the increase of the parts' density and properties.


Subject(s)
Nanocomposites/chemistry , Nanotubes, Carbon/chemistry , Nylons/chemistry , Electric Conductivity , Lasers , Models, Theoretical , Thermal Conductivity
5.
Mater Sci Eng C Mater Biol Appl ; 46: 52-61, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25491959

ABSTRACT

Surface modification of an implant with a biomolecule is used to improve its biocompatibility and to reduce post-implant complications. In this study, a novel approach has been used to functionalise phosphonic acid monolayers with a drug. Ti6Al4V components fabricated using selective laser melting (SLM) were functionalised with Paracetamol (a pharmaceutically relevant biomolecule) using phosphonic acid based self-assembled monolayers (SAMs). The attachment, stability of the monolayers on the SLM fabricated surface and functionalisation of SAMs with Paracetamol were studied using X-ray photoelectron spectroscopy (XPS) and surface wettability measurements. The obtained results confirmed that SAMs were stable on the Ti6Al4V surface for over four weeks and then began to desorb from the surface. The reaction used to functionalise the phosphonic acid monolayers with Paracetamol was noted to be successful. Thus, the proposed method has the potential to immobilise drugs/proteins to SAM coated surfaces and improve their biocompatibility and reduce post-implant complications.


Subject(s)
Coated Materials, Biocompatible/chemistry , Lasers , Titanium/chemistry , Acetaminophen , Alloys , Drug Stability , Photoelectron Spectroscopy , Surface Properties
6.
Lab Chip ; 13(23): 4583-90, 2013 Dec 07.
Article in English | MEDLINE | ID: mdl-24100659

ABSTRACT

We review the use of additive manufacturing (AM) as a novel manufacturing technique for the production of milli-scale reactor systems. Five well-developed additive manufacturing techniques: stereolithography (SL), multi-jet modelling (MJM), selective laser melting (SLM), laser sintering (LS) and fused deposition modelling (FDM) were used to manufacture a number of miniaturised reactors which were tested using a range of organic and inorganic reactions.

7.
Acta Biomater ; 3(2): 221-31, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17215172

ABSTRACT

The biological performance of a porous apatite-mullite glass-ceramic, manufactured via a selective laser sintering (SLS) method, was evaluated to determine its potential as a bone replacement material. Direct contact and extract assays were used to assess the cytotoxicity of the material. A pilot animal study, implanting the material into rabbit tibiae for 4 weeks, was also carried out to assess in vivo bioactivity. The material produced by SLS did not show any acute cytotoxic effects by either contact or extract methods. There was no evidence of an apatite layer forming on the surface of the material when soaked in SBF for 30 days, suggesting that the material was unlikely to exhibit bioactive behaviour in vivo. It is hypothesized that the material was unable to form an apatite layer in SBF due to the fact that this glass-ceramic was highly crystalline and the fluorapatite crystal phase was relatively stable in SBF, as were the two aluminosilicate crystal phases. There was thus no release of calcium and phosphorus and no formation of silanol groups to trigger apatite deposition from solution within the test time period. Following implantation in rabbit tibiae for 4 weeks, bone was seen to have grown into the porous structure of the laser-sintered parts, and appeared to be very close to, or directly contacting, the material surface. This result may reflect the local environment in vivo compared to that artificially found with the in vitro SBF test and, furthermore, confirms previous in vivo data on these glass-ceramics.


Subject(s)
Aluminum Silicates/chemistry , Apatites/chemistry , Biocompatible Materials/chemistry , Bone Substitutes/chemistry , Ceramics/chemistry , Glass/chemistry , Tibia/metabolism , Animals , Body Fluids/metabolism , Lasers , Materials Testing , Microscopy, Electron, Scanning , Rabbits , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...