Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 10(8): e0136419, 2015.
Article in English | MEDLINE | ID: mdl-26295337

ABSTRACT

The objective of this study was to design and validate a next-generation sequencing assay (NGS) to detect BRCA1 and BRCA2 mutations. We developed an assay using random shearing of genomic DNA followed by RNA bait tile hybridization and NGS sequencing on both the Illumina MiSeq and Ion Personal Gene Machine (PGM). We determined that the MiSeq Reporter software supplied with the instrument could not detect deletions greater than 9 base pairs. Therefore, we developed an alternative alignment and variant calling software, Quest Sequencing Analysis Pipeline (QSAP), that was capable of detecting large deletions and insertions. In validation studies, we used DNA from 27 stem cell lines, all with known deleterious BRCA1 or BRCA2 mutations, and DNA from 67 consented control individuals who had a total of 352 benign variants. Both the MiSeq/QSAP combination and PGM/Torrent Suite combination had 100% sensitivity for the 379 known variants in the validation series. However, the PGM/Torrent Suite combination had a lower intra- and inter-assay precision of 96.2% and 96.7%, respectively when compared to the MiSeq/QSAP combination of 100% and 99.4%, respectively. All PGM/Torrent Suite inconsistencies were false-positive variant assignments. We began commercial testing using both platforms and in the first 521 clinical samples MiSeq/QSAP had 100% sensitivity for BRCA1/2 variants, including a 64-bp deletion and a 10-bp insertion not identified by PGM/Torrent Suite, which also suffered from a high false-positive rate. Neither the MiSeq nor PGM platform with their supplied alignment and variant calling software are appropriate for a clinical laboratory BRCA sequencing test. We have developed an NGS BRCA1/2 sequencing assay, MiSeq/QSAP, with 100% analytic sensitivity and specificity in the validation set consisting of 379 variants. The MiSeq/QSAP combination has sufficient performance for use in a clinical laboratory.


Subject(s)
BRCA1 Protein/genetics , BRCA2 Protein/genetics , Biological Assay , Breast Neoplasms/genetics , Genetic Testing/methods , User-Computer Interface , Breast Neoplasms/diagnosis , Cell Line, Tumor , Female , Genetic Testing/instrumentation , High-Throughput Nucleotide Sequencing , Humans , Mutation , Sensitivity and Specificity , Sequence Analysis, DNA
2.
PLoS One ; 8(8): e71703, 2013.
Article in English | MEDLINE | ID: mdl-23990977

ABSTRACT

BACKGROUND: Response to cetuximab (Erbitux®) and panitumumab (Vectibix®) varies among individuals, and even those who show response ultimately gain drug resistance. One possible etiologic factor is differential interaction between the drug and target. We describe the development of an assay based on Slow Off-rate Modified Aptamer (SOMAmer(™)) reagents that can distinguish drug-bound from unbound epidermal growth factor receptor (EGFR). METHODS: This quantitative assay uses a SOMAmer reagent specific for EGFR extracellular domain (ECD) as a capturing reagent. Captured SOMAmer is quantitated using PCR. Linearity and accuracy (recovery) of the assay were assessed using normal sera and purified EGFR ECD. RESULTS: This EGFR ECD assay showed linearity between 2.5 and 600 ng/mL. Average recovery was 101%. The assay detected EGFR but showed little cross-reactivity to other ErbB proteins: 0.4% for ErbB2, 6.9% for ErbB3, and 1.3% for ErbB4. Preincubation of normal serum with either cetuximab or panitumumab resulted in a dose-dependent decrease in EGFR ECD levels measured using the SOMAmer assay; preincubation did not affect measurement with an ELISA. CONCLUSIONS: This SOMAmer-based serum EGFR ECD assay accurately and specifically measures EGFR in serum. Detection of significant amounts of drug-unbound EGFR in patients undergoing cetuximab or panitumumab treatment could be an indicator of poor drug response. Further studies are needed to evaluate the utility of the assay as an indicator of drug efficacy or as a guide to dosing.


Subject(s)
Antibodies, Monoclonal, Humanized/metabolism , Antibodies, Monoclonal/metabolism , Clinical Laboratory Techniques/methods , ErbB Receptors/blood , Antibodies, Monoclonal/administration & dosage , Antibodies, Monoclonal, Humanized/administration & dosage , Antineoplastic Agents/administration & dosage , Antineoplastic Agents/metabolism , Aptamers, Nucleotide/genetics , Aptamers, Nucleotide/metabolism , Binding Sites , Binding, Competitive , Biomarkers/blood , Cetuximab , Enzyme-Linked Immunosorbent Assay , ErbB Receptors/antagonists & inhibitors , ErbB Receptors/metabolism , Humans , Panitumumab , Polymerase Chain Reaction , Receptor, ErbB-2/antagonists & inhibitors , Receptor, ErbB-2/blood , Receptor, ErbB-2/metabolism , Receptor, ErbB-3/antagonists & inhibitors , Receptor, ErbB-3/blood , Receptor, ErbB-3/metabolism , Receptor, ErbB-4 , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...