Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1715: 464631, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38184989

ABSTRACT

This study investigated the removal of Reactive Blue 21 (RB 21) dye from aqueous solutions by adsorption, evaluating the waste fly ash (FA). The effects of the parameters, such as initial dye concentration (100-750 mg/L), initial pH (2.0-8.0), adsorbent dose (1.0-4.0 g/L), and temperature (298-323 K) on the adsorption process were investigated. The optimum initial pH value was 2.0 for the highest RB21 dye removal (75.2 mg/g). At optimized conditions (pH 2.0, an adsorbent dosage of 1.0 g/L, a dye concentration of 750 mg/L, and an equilibrium time of 72 h), the highest adsorption capacity was found to be 105.2 mg/g. Moreover, the results of the kinetic studies fitted the pseudo-second-order kinetic model. Equilibrium data were best represented by the Langmuir isotherm model, with a maximum monolayer adsorption capacity of 103.41 mg/g at 323 K. ΔGads0 values were negative and varied from 11.64 to 9.50 kJ/mol in the temperature range of 298-323 K, the values of enthalpy (ΔHadso) and entropy (ΔSadso) of thermodynamics parameters were calculated as 37.62 kJ/mol and 86.67 J/mol K, respectively, indicating that this process was endothermic. Furthermore, the adsorbent costs for powdered activated carbon (PAC) and FA to remove 1 kg of RB 21 dye from aqueous solutions are calculated as 2.52 U.S. $ and 0.34 U.S. $, respectively. It is seen that the cost of FA is approximately 7.4 times lower than PAC. The results showed that FA, a low-cost industrial waste, was promising for the adsorption of RB 21 from aqueous solutions.


Subject(s)
Metalloporphyrins , Water Pollutants, Chemical , Water Purification , Coal Ash , Kinetics , Water Purification/methods , Thermodynamics , Adsorption , Hydrogen-Ion Concentration
2.
ACS Omega ; 8(9): 8557-8568, 2023 Mar 07.
Article in English | MEDLINE | ID: mdl-36910959

ABSTRACT

The Çanakkale-Kirazli region (Turkey) is enriched with minerals, especially aluminum (Al), which dangerously get transported into aquatic media due to several mining and geological activities in recent years. In this study, Al and other potentially toxic metals (PTMs) including B, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Si, and Zn, in both water and soil samples, were measured for quality determination. Selected metals were also analyzed by the enrichment factor (EF), the geoaccumulation index (I geo), the contamination factor (CF), and the pollution load index (PLI) to evaluate both water and soil pollution geogenically or anthropogenically. Also, the metals were clustered to support the pollution source with Pearson's correlation, principal component analysis (PCA), and hierarchical cluster analysis (HCA). Forty-five natural water samples and 12 soil samples were collected spatially. To perform pollution assessment, two fundamental treatment processes to remove Al pollution from the sample including the highest Al concentration (38.38 mg/L) in water were applied: (1) precipitation with pH adjustment and (2) removal with ion exchange. The pH values of water samples were changed in the range of 3-9 to test the dissolution of Al. The results demonstrated that the study area was mostly under the influence of geogenic aluminum pollution.

3.
ACS Omega ; 7(41): 36457-36467, 2022 Oct 18.
Article in English | MEDLINE | ID: mdl-36278098

ABSTRACT

Countrywide surface soil concentrations of potentially toxic elements (PTEs) in Turkey were reviewed in the Web of Science database. A total of 93 papers were investigated to compose a PTE dataset for determining spatial variations and estimating exposure and health risks. Al, As, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, and Zn were selected as PTEs in surface soil. A compiled PTE concentration dataset was used to estimate chronic toxic risks (CTRs) and carcinogenic risks (CRs) according to the deterministic and probabilistic approaches. While the CTR and CR levels of age and sex groups were estimated using a deterministic approach, population risks were estimated using a probabilistic approach. CTR and CR levels in lower age groups and female sex groups were estimated to be higher than those in higher age groups and associated male sex groups. The average CTR levels of the nondietary ingestion of As-containing soil in <11 year age groups were near/just above the threshold level, while As-associated average CR levels of adults and other age groups were estimated to be in the acceptable risk range (10-6 < CR < 10-5) and low priority risk range (10-5 < CR < 10-4), respectively. As-, Cr(VI)-, and Pb-associated upper-bound CR levels of the Turkish population were simulated to be 5.14 × 10-4, 6.23 × 10-5, and 2.34 × 10-6, respectively. Health risk models show the significance of As in both chronic toxic and carcinogenic effects.

4.
Heliyon ; 8(9): e10489, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36105457

ABSTRACT

Electrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 µg L-1, GW-2: 1132.1 µg L-1, and GW-3: 52, 000 µg L-1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 µg L-1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were >99.9%, 180 min and 0.406 $ m-3 for ball anodes, >99.9%, 100 min and 0.0813 $ m-3 for plate anodes, >99.9%, 80 min and 0.0815 $ m-3 for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.

5.
ACS Omega ; 7(36): 32640-32652, 2022 Sep 13.
Article in English | MEDLINE | ID: mdl-36119975

ABSTRACT

In this study, electrochemical removal of methylene blue (MB) from water using commercially available and low-cost flexible graphite was investigated. The operating conditions such as initial dye concentration, initial solution pH, electrolyte dose, electrical potential, and operating time were investigated. The Box-Behnken experimental design (BBD) was used to optimize the system's performance with the minimum number of tests possible, as well as to examine the independent variables' impact on the removal efficiency, energy consumption, operating cost, and effluent MB concentration. The electrical potential and electrolyte dosage both improved the MB removal efficiency, since increased electrical potential facilitated production of oxidizing agents and increase in electrolyte dosage translated into an increase in electrical current transfer. As expected, MB removal efficiency increased with longer operational periods. The combined effects of operating time-electrical potential and electrical potential-electrolyte concentration improved the MB removal efficiency. The maximum removal efficiency (99.9%) and lowest operating cost (0.012 $/m3) were obtained for initial pH 4, initial MB concentration 26.5 mg/L, electrolyte concentration 0.6 g/L, electrical potential 3 V, and operating time 30 min. The reaction kinetics was maximum for pH 5, and as the pH increased the reaction rates decreased. Consequent techno-economic assessment showed that electrochemical removal of MB using low-cost and versatile flexible graphite had a competitive advantage.

6.
Sci Total Environ ; 808: 152135, 2022 Feb 20.
Article in English | MEDLINE | ID: mdl-34864021

ABSTRACT

Arsenic (As) occurrence in water resources has become one of the most critical environmental problems worldwide. The detrimental health impacts on humans have been reported due to the consumption of As-contaminated groundwater resources. Consumption of As-containing water over the long term can cause arsenicosis and chronic effects on human health due to its toxicity. Several treatment processes are available for As removals such as coagulation, ion exchange, adsorption, and membrane technologies but they have various major drawbacks. In the present work, therefore, an aerated electrocoagulation (EC) system with aluminum anodes was operated for simultaneous arsenate (As(V)) and arsenite (As(III)) removal to overcome the disadvantages of other processes such as, sludge formation, difficulties in operation, high operating costs, high energy consumption, and the requirement of pre-treatment process and to enhance the conventional EC process. The combined effects of the applied current (0.075-0.3 A), aeration rate (0-6 L/min), pH (6.5-8.5), and As speciation (As(V)-As(III)) were studied on As removal efficiency. The findings revealed that As removal mostly depended on the airflow rate and the applied current in the EC system. The highest As removal efficiency (99.1%) was obtained at an airflow rate of 6 L/min, a pH of 6.5, an initial As (V) concentration of 200 µg/L, and a current of 0.3 A, with an energy consumption of 2.85 kWh/m3 and an operating cost of 0.66 $/m3. The human health risk assessment of treated water was also examined to understand the performance of the EC system. At most of the experimental runs, the chronic toxic risk (CTR) and carcinogenic risk (CR) of As were within the permissible limits except for an airflow rate of 0-2 L/min, an initial pH of 8.5, and a current of 0.075-0.15 A for high initial As (III) concentrations. Overall, the As removal performance and groundwater risk assessment show that the EC process is a promising option for industrial applications.


Subject(s)
Arsenic , Arsenites , Groundwater , Water Pollutants, Chemical , Water Purification , Adsorption , Arsenates/toxicity , Arsenic/toxicity , Arsenites/toxicity , Electrocoagulation , Humans , Water Pollutants, Chemical/toxicity
7.
Environ Chall (Amst) ; 5: 100239, 2021 Dec.
Article in English | MEDLINE | ID: mdl-38620652

ABSTRACT

The COVID-19 pandemic, which has reached 4 million global cases as of March 10, 2020, has become a worldwide problem. Turkey is one of the most affected (9th in the world) country with 139 771 cases. An intermittent curfew policy that differ for three age groups, and an intercity travel ban varying within the country have been implemented. The effects of changes in social life and industrial activity in terms of environmental pollution are not yet known. The short-term effects on PM2.5, PM10, SO2, NO2, NO, NOx, O3 and CO concentrations measured at 51 air quality measurement stations (AQMS) in 11 cities in March - April period of 2020 were statistically compared with that of the previous year. While PM2.5 (9/14 AQMS) and PM10 (29/35 AQMS) concentrations were not significantly affected, NO (12/24 AQMS), NO2 (20/29 AQMS), NOX (17/25 AQMS) concentrations were decreased, SO2 concentrations at half of the AQMSs (11/25) did not show a significant change. There were stations at which higher pollutant concentrations were measured in the study period in 2020 compared to that of 2019. Excess risks associated with PM2.5 and PM10 were estimated to be variable, albeit with a small difference. In conclusion, the heterogeneous actions taken in response to the COVID-19 pandemic resulted in mixed effects on ambient air quality.

8.
Sci Total Environ ; 683: 411-426, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31141744

ABSTRACT

Feasible reclamation of industrial wastewaters by consuming less resource and time requires researchers to develop advanced and sophisticated solutions to meet today's versatile needs. In this respect, novel technological applications of hybrid membrane oxidation reactor (MOR) comprising of the Fenton or photo-Fenton enhanced ultrafiltration (FEUF and pFEUF), was demonstrated for treating textile washing wastewater. Their comparative hybrid performances were explored based on response surface analyses of Taguchi experimental designs that were optimized for maximized responses at minimum oxidant and acid consumptions. From eleven specific variables, those affecting the hybrid treatment performances at significant levels were found as H2O2 amount, process time, membrane type, Fe2+ concentration and temperature. The pFEUF treatment showed better and faster organics removal efficiency than by FEUF, and the UF process was seen to be more affected from changing operational conditions in pFEUF. Organic pollutants were oxidized by 56.6 ±â€¯8.7% degradation and 31.5 ±â€¯3.2% mineralization, while UF allowed a synergistic contribution to the hybrid MOR performance by 38.1 ±â€¯4.7% and 17.3 ±â€¯3.1%, respectively. Compared to simultaneous MOR and external UF after Fenton, sequential MOR was found as the best solution by an efficiency of 84.5% COD, 70.5% TOC, and 155.6 L/m2·h. The effluents could be readily produced with quality suitable for directly discharging to the sewage infrastructure system resulting in a complete treatment. This study proved that the developed MOR techniques are technologically favorable for the treatment of industrial organic wastewaters due to high treatment performances and less resource, time and land needs. It can be finally declared that they can be used as rather attractive solutions for not only wastewater reclamation but also water recovery by further handling of their effluents.

SELECTION OF CITATIONS
SEARCH DETAIL
...