Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
Add more filters










Publication year range
1.
Indian J Ophthalmol ; 72(5): 741-744, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38189430

ABSTRACT

Slit lamp biomicroscope is the right hand of an Ophthalmologist. Even though precise, its bulky design and complex working process are limiting constraints, making it difficult for screening at outreach camps, which are an integral part of this field for the purpose of eliminating needless blindness. The torchlight is the main tool used for screening. Recently, the integration of smartphones with instruments and the digitization of slit lamp has been explored, to provide simple and easy hacks. By bringing the slit of the slit lamp to traditional torchlight, we have created "The Slitscope". It combines the best of both worlds as a simple innovative do-it-yourself novel technique for precise cataract screening. It is especially useful in peripheral centers, vision centers, and outreach camps. We present two prototypes which can also be 3D printed.


Subject(s)
Equipment Design , Slit Lamp Microscopy , Humans , Cataract/diagnosis , Vision Screening/methods , Vision Screening/instrumentation , Smartphone
2.
Indian J Ophthalmol ; 71(12): 3715-3717, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37991310

ABSTRACT

Surgery, by nature, involves blood loss. Thus, suction plays an important role in ensuring a clean operating view and ease of access. In ophthalmology, there is a void for an efficient and flexible suction apparatus that is yet to be filled. Our innovation, the Eyespirator, is made using recycled or inexpensive parts, is easy to assemble, and can serve as a cost-effective alternative to the current apparatus under use. It helps to overcome the difficulties caused by large instruments and non-pliable suction tips, unregulated generation of vacuum, and high pressures generated causing trauma to the delicate structures, and can prove to be of immense use in fields such as ophthalmology where the small surgical field is a big challenge. It creates a vacuum by using a simple water pump and is regulated by a foot pedal. This can be deployed even in rural settings, and small modifications can allow its usage in a wide variety of surgical fields.


Subject(s)
Suction , Humans , Vacuum
3.
Indian J Ophthalmol ; 71(8): 3005-3009, 2023 08.
Article in English | MEDLINE | ID: mdl-37530273

ABSTRACT

Purpose: To compare glaucomatous from non-glaucomatous optic atrophy using optical coherence tomography (OCT) based on the measurement values of Bruch's membrane opening minimum rim width (BMO-MRW), which is a difficult task otherwise due to their varied course of disease progression, treatment protocols, and systemic association to visual impairment. Methods: This study was conducted in 40 eyes, comprising 20 eyes with non-glaucomatous optic neuropathy (NGON) and 20 eyes with glaucomatous optic neuropathy (GON). All patients underwent a complete ophthalmic examination followed by an OCT optic disc scan to calculate the measurement of BMO-MRW. Results: The 5-fold cross-validated area under the curve for GON versus NGON from logistic regression models was 0.95 (95% confidence interval [CI]: 0.86-1.00) using BMO-MRW values from all sectors. The results revealed that the measurements were significantly lesser in GON than in NGON patients. Conclusion: Hence, OCT-based BMO-MRW values could be used as an additional test to compare glaucomatous with non-glaucomatous optic neuropathy patients, especially in cases of high clinical suspicion.


Subject(s)
Glaucoma , Optic Nerve Diseases , Humans , Tomography, Optical Coherence/methods , Bruch Membrane , Intraocular Pressure , Retinal Ganglion Cells , Visual Fields , Nerve Fibers , Glaucoma/diagnosis , Optic Nerve Diseases/diagnosis
7.
Indian J Ophthalmol ; 71(1): 290-293, 2023 01.
Article in English | MEDLINE | ID: mdl-36588254

ABSTRACT

In this report, we have utilized a smartphone-based innovative tool named anterior segment photography with an intraocular lens (ASPI) with a cobalt blue filter on the smartphone flash for photographing fluorescein-stained corneas. An intraocular lens along with a cobalt blue filter was attached to the smartphone camera to achieve this purpose. The filter could block out all wavelengths of light except the blue wavelength (450-490 nm) emerging from the smartphone camera. A pilot study was conducted on 27 eyes of 25 patients where images of various corneal pathologies were obtained using ASPI blue light imaging. The images were clear and highly magnified and could be used for documentation, teleconsultation for expert opinion, education, and monitoring of disease progression. ASPI-aided blue light imaging could be easily fabricated and is a frugal inexpensive device, which is used by different ophthalmic personnel to obtain fluorescein-stained corneal images.


Subject(s)
Lenses, Intraocular , Smartphone , Humans , Pilot Projects , Coloring Agents/pharmacology , Photography/methods , Cornea , Fluorescein
8.
Indian J Ophthalmol ; 70(8): 3112-3115, 2022 08.
Article in English | MEDLINE | ID: mdl-35918982

ABSTRACT

The authors describe a novel technique of performing retinoscopy assisted with a smartphone (gimbalscope). We found this technique of digital retinoscopy to be useful for demonstrating and documenting retinoscopic reflexes and in addition as an easy teaching tool. This technical report explains the assembly of our smartphone-assisted retinoscope and provides examples of the range of normal and abnormal reflexes that can be captured.


Subject(s)
Retinoscopes , Retinoscopy , Humans , Refraction, Ocular , Smartphone
10.
Oman J Ophthalmol ; 15(1): 95-98, 2022.
Article in English | MEDLINE | ID: mdl-35388240

ABSTRACT

A 44-year-old woman presented with complaints of pain in the right eye (RE). Fundus examination revealed disc edema in the RE along with retinal flecks sparing the macula in both eyes (BE). Fundus autofluorescence demonstrated a symmetrical pattern of white flecks in BE. Spectral-domain optical coherence tomography (SD-OCT) revealed the lesions at the level of retinal pigment epithelium with impingement onto the outer retina. SD-OCT angiography through the flecks revealed hyperreflective lesions at the level of avascular retina. RE B-scan revealed a T-sign. Based on these findings, she was diagnosed with BE benign familial fleck retina (BFFR) with RE posterior scleritis. We describe the multimodal imaging features in a middle-aged patient with BFFR and provide an insight into the probable pathogenesis.

11.
Eye Contact Lens ; 48(7): 306-307, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35333809

ABSTRACT

ABSTRACT: Demodex is an important pathogen causing eyelid and eyelash diseases. This article describes a quick, efficient, cost-effective office-based imaging of demodex with the help of an intraocular lens (IOL) and smartphone-aided innovated tool. Eyelid photography of a 56-year-old man with suspected demodex infestation was obtained using a 20-diopter (D) IOL over the smartphone camera called as Anterior Segment Photography using IOL (ASPI). A video or photograph of the epilated eyelash was taken using four 30-D IOLs attached to the smartphone camera to form an optical system called IOLSCOPE, which clearly detected the demodex parasite. The importance of ASPI and IOLSCOPE for the rapid office-based diagnosis of demodex pathogen in peripheral health centers devoid of slitlamp and microscopes has been emphasized here.


Subject(s)
Eyelashes , Lenses, Intraocular , Eyelashes/parasitology , Humans , Male , Middle Aged , Photography , Slit Lamp Microscopy , Smartphone
12.
Indian J Ophthalmol ; 70(4): 1381-1383, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35326059

ABSTRACT

The emergence of smartphone-based imaging devices has been a boon in the field of ophthalmology, especially in obtaining high-quality ocular images. They can be specialized and utilized for imaging-specific regions of the eye. Among the multitude of applications of smartphone-based imaging, one of the upcoming major use is to image the microbiological world. Previous few reports have described attaching magnifying lenses of various types to the smartphone camera and transforming it into a microscope for imaging fungal hyphae and ocular surface parasites. We describe a novel technique of attaching the smartphone-based intraocular lens microscope (IOLSCOPE) to the slit lamp, thereby utilizing the slit lamp joystick for moving the smartphone over the concerned slide specimen to make it steady and obtain images of high resolution. This innovative do-it-yourself novel modification is especially useful in peripheral centers, vision centers, and local clinics for immediate screening and identification of microbial pathogens such as fungi and ocular surface parasites.


Subject(s)
Lenses, Intraocular , Slit Lamp , Humans , Microscopy , Slit Lamp Microscopy , Smartphone
13.
J Glaucoma ; 31(5): 356-360, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35220386

ABSTRACT

Gonioscopy is an important part of glaucoma diagnosis and management. Imaging and documentation of the anterior chamber angle has been previously performed using slit-lamp-assisted photography or using smartphones with or without an attached macro lens. Smartphones have transformed ophthalmic imaging by virtue of their availability, easy use, and portability. In this report, the authors aim to demonstrate gonio-imaging using a smartphone attached with an intraocular lens which behaves like a macro lens. With the patient in a sitting position or in the supine position, a goniolens is placed on the patient's cornea. A smartphone with a 10 D intraocular lens attachment over its camera is used to take images or videos of the anterior chamber angle with high magnification. This imaging modality is cost-effective and can be used for screening and photographic documentation of the angle, and can be of immense benefit, especially in primary health care centers.


Subject(s)
Lenses, Intraocular , Smartphone , Cost-Benefit Analysis , Gonioscopy , Humans , Intraocular Pressure , Photography
15.
Eye Contact Lens ; 48(1): 54-56, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-34924544

ABSTRACT

PURPOSE: To evaluate the use of smartphone-based innovative tools named Anterior segment photography with intraocular lens (ASPI) and smartphone based intraocular lens microscope (IOLSCOPE) to demonstrate, treat, and diagnose the patients of ophthalmomyiasis caused by Oestrus ovis. METHODS: A retrospective interventional case series of six patients infested with O. ovis presenting in a rural health center with symptoms of burning, itching, watering, and foreign body sensation diagnosed with ophthalmomyiasis. Diagnosis and treatment were performed using an innovative imaging technique that is, an optical system formed by intraocular lens (IOL) and smartphone. RESULTS: The smartphone-based ASPI clearly detected and removed the moving larvae from the ocular surface, followed by microbiological diagnosis of O.ovis larvae with the help of an IOLSCOPE. CONCLUSION: The importance of ASPI and IOLSCOPE for the management of ophthalmomyiasis in peripheral health centers devoid of slitlamp and microscopes has been emphasized here.


Subject(s)
Eye Diseases , Smartphone , Animals , Humans , Retrospective Studies , Sheep , Slit Lamp , Slit Lamp Microscopy
16.
SELECTION OF CITATIONS
SEARCH DETAIL
...