1.
Phys Med ; 123: 103407, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38906046

ABSTRACT

PURPOSE: To investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI). METHODS: A multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process. RESULTS: Eleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow. CONCLUSION: There were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.


Subject(s)
Radiotherapy, Image-Guided , Humans , Radiotherapy, Image-Guided/methods , Europe , Craniospinal Irradiation/methods , Surveys and Questionnaires , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed , Delphi Technique , Magnetic Resonance Imaging
2.
Phys Med Biol ; 69(11)2024 May 20.
Article in English | MEDLINE | ID: mdl-38657625

ABSTRACT

Objective.The superior dose conformity provided by proton therapy relative to conventional x-ray radiotherapy necessitates more rigorous quality assurance (QA) procedures to ensure optimal patient safety. Practically however, time-constraints prevent comprehensive measurements to be made of the proton range in water: a key parameter in ensuring accurate treatment delivery.Approach.A novel scintillator-based device for fast, accurate water-equivalent proton range QA measurements for ocular proton therapy is presented. Experiments were conducted using a compact detector prototype, the quality assurance range calorimeter (QuARC), at the Clatterbridge cancer centre (CCC) in Wirral, UK for the measurement of pristine and spread-out Bragg peaks (SOBPs). The QuARC uses a series of 14 optically-isolated 100 × 100 × 2.85 mm polystyrene scintillator sheets, read out by a series of photodiodes. The detector system is housed in a custom 3D-printed enclosure mounted directly to the nozzle and a numerical model was used to fit measured depth-light curves and correct for scintillator light quenching.Main results.Measurements of the pristine 60 MeV proton Bragg curve found the QuARC able to measure proton ranges accurate to 0.2 mm and reduced QA measurement times from several minutes down to a few seconds. A new framework of the quenching model was deployed to successfully fit depth-light curves of SOBPs with similar range accuracy.Significance.The speed, range accuracy and simplicity of the QuARC make the device a promising candidate for ocular proton range QA. Further work to investigate the performance of SOBP fitting at higher energies/greater depths is warranted.


Subject(s)
Calorimetry , Calorimetry/instrumentation , Quality Control , Proton Therapy/instrumentation , Humans