Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 10(2)2023 Jan 20.
Article in English | MEDLINE | ID: mdl-36829635

ABSTRACT

Fast Blue (FB) and Cholera Toxin-B (CTB) are two retrograde tracers extensively used to label alpha-motoneurons (α-MNs). The overall goals of the present study were to (1) assess the effectiveness of different FB and CTB protocols in labeling α-MNs, (2) compare the labeling quality of these tracers at standard concentrations reported in the literature (FB 2% and CTB 0.1%) versus lower concentrations to overcome tracer leakage, and (3) determine an optimal protocol for labeling α-MNs in young B6SJL and aged C57Bl/J mice (when axonal transport is disrupted by aging). Hindlimb muscles of young B6SJL and aged C57Bl/J mice were intramuscularly injected with different FB or CTB concentrations and then euthanized at either 3 or 5 days after injection. Measurements were performed to assess labeling quality via seven different parameters. Our results show that tracer protocols of lower concentration and shorter labeling durations were generally better in labeling young α-MNs, whereas tracer protocols of higher tracer concentration and longer labeling durations were generally better in labeling aged α-MNs. A 0.2%, 3-day FB protocol provided optimal labeling of young α-MNs without tracer leakage, whereas a 2%, 5-day FB protocol or 0.1% CTB protocol provided optimal labeling of aged α-MNs. These results inform future studies on the selection of optimal FB and CTB protocols for α-MNs labeling in normal, aging, and neurodegenerative disease conditions.

2.
J Am Assoc Lab Anim Sci ; 56(1): 69-78, 2017 Jan 01.
Article in English | MEDLINE | ID: mdl-28905718

ABSTRACT

Rodent euthanasia using exposure to increasing concentrations of CO2 has come under scrutiny due to concerns of potential pain during the euthanasia process. Alternatives to CO2, such as isoflurane and barbiturates, have been proposed as more humane methods of euthanasia. In this study, we examined 3 commonly used euthanasia methods in mice: intraperitoneal injection of pentobarbital-phenytoin solution, CO2 inhalation, and isoflurane anesthesia followed by CO2 inhalation. We hypothesized that pentobarbital-phenytoin euthanasia would cause fewer alterations in cardiovascular response, result in less behavioral evidence of pain or stress, and produce lower elevations in ACTH than would the isoflurane and CO2 methods, which we hypothesized would not differ in regard to these parameters. ACTH data suggested that pentobarbital-phenytoin euthanasia may be less stressful to mice than are isoflurane and CO2 euthanasia. Cardiovascular, behavioral, and activity data did not consistently or significantly support isoflurane or pentobarbital-phenytoin euthanasia as less stressful methods than CO2. Euthanasia with CO2 was the fastest method of the 3 techniques. Therefore, we conclude that using CO2 with or without isoflurane is an acceptable euthanasia method. Pathologic alterations in the lungs were most severe with CO2 euthanasia, and alternative euthanasia techniques likely are better suited for studies that rely on analysis of the lungs.


Subject(s)
Anesthesia/veterinary , Carbon Dioxide/pharmacology , Euthanasia, Animal/methods , Isoflurane/pharmacology , Pentobarbital/pharmacology , Anesthesia/methods , Anesthetics, Inhalation/pharmacology , Animals , Hypnotics and Sedatives/pharmacology , Injections, Intraperitoneal , Male , Mice , Mice, Inbred C57BL , Pain/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...