Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 15045, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951558

ABSTRACT

Near-seafloor concentrated gas hydrates (GHs) containing large amounts of methane have been identified at various gas chimney sites. Although understanding the spatial distribution of GHs is fundamental for assessing their dissociation impact on aggravating global warming and resource potential, the spatial distribution of GHs within gas chimneys remains unclear. Here, we estimate the subseafloor distribution of GHs at a gas chimney site in the Japan Sea using marine electrical resistivity tomography data. The resulting two-dimensional subseafloor resistivity structure shows high anomalies (10-100 Ωm) within seismically inferred gas chimneys. As the resistivity anomalies are aligned with high amplitude seismic reflections and core positions recovering GHs, we interpret the resistivity anomalies are near-seafloor concentrated GH deposits. We also detect various distribution patterns of the high resistivity anomalies including 100-m wide and 40-m thick anomaly near the seafloor and 500-m wide anomaly buried 50 m below the seafloor, suggesting that GHs are heterogeneously distributed. Therefore, considering such heterogeneous GH distribution within gas chimneys is critical for in-depth assessments of GH environmental impacts and energy resources.

2.
Sensors (Basel) ; 9(11): 9241-54, 2009.
Article in English | MEDLINE | ID: mdl-22291563

ABSTRACT

Sagami Bay is an active tectonic area in Japan. In 1993, a real-time deep sea floor observatory was deployed at 1,175 m depth about 7 km off Hatsushima Island, Sagami Bay to monitor seismic activities and other geophysical phenomena. Video cameras monitored biological activities associated with tectonic activities. The observation system was renovated completely in 2000. An ocean bottom electromagnetic meter (OBEM), an ocean bottom differential pressure gauge (DPG) system, and an ocean bottom gravity meter (OBG) were installed January 2005; operations began in February of that year. An earthquake (M5.4) in April 2006, generated a submarine landslide that reached the Hatsushima Observatory, moving some sensors. The video camera took movies of mudflows; OBEM and other sensors detected distinctive changes occurring with the mudflow. Although the DPG and OBG were recovered in January 2008, the OBEM continues to obtain data.

SELECTION OF CITATIONS
SEARCH DETAIL
...