1.
Phys Rev Lett ; 124(12): 122003, 2020 Mar 27.
Article in English | MEDLINE | ID: mdl-32281834

ABSTRACT

We report on a new measurement of the beam transverse single spin asymmetry in electron-proton elastic scattering, A_{⊥}^{ep}, at five beam energies from 315.1 to 1508.4 MeV and at a scattering angle of 30°<θ<40°. The covered Q^{2} values are 0.032, 0.057, 0.082, 0.218, 0.613 (GeV/c)^{2}. The measurement clearly indicates significant inelastic contributions to the two-photon-exchange (TPE) amplitude in the low-Q^{2} kinematic region. No theoretical calculation is able to reproduce our result. Comparison with a calculation based on unitarity, which only takes into account elastic and πN inelastic intermediate states, suggests that there are other inelastic intermediate states such as ππN, KΛ, and ηN. Covering a wide energy range, our new high-precision data provide a benchmark to study those intermediate states.

2.
Appl Radiat Isot ; 116: 185-9, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27620063

ABSTRACT

A benchmark experiment for validation of graphite data evaluated from nuclear data libraries was conducted for 14MeV neutrons irradiated on graphite cylinder samples. The experiments were performed using the benchmark experimental facility at the China Institute of Atomic Energy (CIAE). The leakage neutron spectra from the surface of graphite (Φ13cm×20cm) at 60° and 120° and graphite (Φ13cm×2cm) at 60° were measured by the time-of-flight (TOF) method. The obtained results were compared with the measurements made by the Monte Carlo neutron transport code MCNP-4C with the ENDF/B-VII.1, CENDL-3.1 and JENDL-4.0 libraries. The results obtained from a 20cm-thick sample revealed that the calculation results with CENDL-3.1 and JENDL-4.0 libraries showed good agreements with the experiments conducted in the whole energy region. However, a large discrepancy of approximately 40% was observed below the 3MeV energy region with the ENDF/B-VII.1 library. For the 2cm-thick sample, the calculated results obtained from the abovementioned three libraries could not reproduce the experimental data in the energy range of 5-7MeV. The graphite data in CENDL-3.1 were verified for the first time and were proved to be reliable.

3.
Phys Rev A ; 43(7): 3260-3269, 1991 Apr 01.
Article in English | MEDLINE | ID: mdl-9905408
SELECTION OF CITATIONS
SEARCH DETAIL
...