Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 4242, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38378858

ABSTRACT

Radioactive iodine isotopes especially 131I are used for diagnosis and treatment of different types of cancer diseases. Due to the leak of radioactive iodine into the patient's urine in turn, the wastewater would be contaminated, so it is worth preparing a novel adsorption green material to remove the radioactive iodine from wastewater efficiently. The removal of 127I and 131I contaminants from aqueous solution is a problem of interest. Therefore, this work presents a new study for removing the stable iodine 127I- and radioactive iodine 131I from aqueous solutions by using the novel nano adsorbent (Nano ZnO/MWCNTs) which is synthesized by the arc discharge method. It is an economic method for treating contaminated water from undesired dissolved iodine isotopes. The optimal conditions for maximum removal are (5 mg/100 ml) as optimum dose with shacking (200 rpm) for contact time of (60 min), at (25 °C) in an acidic medium of (pH = 5). After the adsorption process, the solution is filtrated and the residual iodide (127I-) is measured at a maximum UV wavelength absorbance of 225 nm. The maximum adsorption capacity is (15.25 mg/g); therefore the prepared nano adsorbent (Nano ZnO/MWCNTs) is suitable for treating polluted water from low iodide concentrations. The adsorption mechanism of 127I- on to the surface of (Nano ZnO/MWCNTs) is multilayer physical adsorption according to Freundlich isotherm model and obeys the Pseudo-first order kinetic model. According to Temkin isotherm model the adsorption is exothermic. The removal efficiency of Nano ZnO/MWCNTs for stable iodine (127I-) from aqueous solutions has reached 97.23%, 89.75%, and 64.78% in case of initial concentrations; 0.1843 ppm, 0.5014 ppm and 1.0331 ppm, respectively. For the prepared radio iodine (131I-) solution of radioactivity (20 µCi), the dose of nano adsorbent was (10 mg/100 ml) and the contact time was (60 min) at (pH = 5) with shacking (200 rpm) at (25 °C). The filtration process was done by using a syringe filter of a pore size (450 nm) after 2 days to equilibrate. The removal efficiency reached (34.16%) after the first cycle of treatment and the percentage of residual radio iodine was (65.86%). The removal efficiency reached (94.76%) after five cycles of treatment and the percentage of residual radio iodine was (5.24%). This last percentage was less than (42.15%) which produces due to the natural decay during 10 days.

2.
Sci Rep ; 14(1): 1578, 2024 Jan 18.
Article in English | MEDLINE | ID: mdl-38238486

ABSTRACT

Recently, there has been a surge of interest in the application of radiation-shielding materials. One promising research avenue involves using free-lead metal oxides/polymer composites, which have been studied for their radiation shielding and characterization properties. This study reinforced the dimethylpolysiloxane (silicone rubber) composites with micro- and nano-sized particles of tin oxide, cadmium oxide, and bismuth oxide as additive materials. The composites were tested with 20 and 50 weight fractions, and their attenuation coefficients were measured using a NaI(TI) detector at gamma-ray energies ranging from 59.54 to 1408.01 keV. Also, the thermal and mechanical properties of the composites were observed and compared with those of free silicone rubber. The results showed that the 50% nano metal oxide/SR composites exhibited better thermal stability and attenuation properties than the other composites, also possessing unique attributes such as lightweight composition and exceptional flexibility. Consequently, this composite material holds immense potential for safeguarding vital organs, including the eyes and gonads, during radiological diagnosis or treatment procedures. Its exceptional ability to absorb a significant portion of incident rays makes it an invaluable asset in the field of radiation protection.

3.
Sci Rep ; 13(1): 18224, 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37880284

ABSTRACT

This study investigates the gamma radiation shielding properties of cement-ball clay matrix composites doped with micro- and nano-sized cadmium oxide (CdO) particles. The linear attenuation coefficient (LAC) was determined using a sodium iodide (NaI) detector and five radioactive point sources with energies ranging from 59.5 to 1408 keV. The LAC values obtained were compared to the XCOM database and found to be in good agreement. The composites' half-value layer (HVL), tenth value layer (TVL), mean free path (MFP), effective atomic number (Zeff), equivalent atomic number (Zeq), and absorption buildup factor (EABF) were determined. The results showed that the addition of CdO particles improved the radiation-shielding behavior of the composites and increasing the weight fraction of CdO particles increased the shielding effectiveness. The results also illustrated that when nano-sized CdO particles were compared to their micro-sized counterparts, there was a significant enhancement in radiation shielding effectiveness. For instance, a composite material composed of 50% cement, 41.7% ball clay, and 3.8% nano CdO at an energy level of 0.0595 MeV exhibited a remarkable 12.2% increase in attenuation, surpassing the performance of the micro-sized sample with an equivalent concentration. Similarly, another composite consisting of 50% cement, 33.3% ball clay, and 16.7% nano CdO demonstrated a significant 15.4% increase in attenuation at the same energy level, when compared to the micro-sized sample. The study demonstrates the potential of CdO-doped cement-ball clay matrix composites for gamma radiation shielding applications.

4.
Sci Rep ; 13(1): 9945, 2023 Jun 19.
Article in English | MEDLINE | ID: mdl-37337045

ABSTRACT

Sheets of high-density polyethylene (HDPE) loaded with magnesium oxide in micro and nano were synthesized with different weight percentages of micro-MgO (0,5,10,20 and 30% by weight) and nano-MgO (5 and 30%) and shaped in form of disc and dog bone shape. The morphological, mechanical, and attenuation characteristics of each concentration were determined. The linear attenuation coefficients (LAC) of the prepared discs were calculated using a well-calibrated scintillation detector and five standard gamma-ray point sources (241Am, 133Ba, 137Cs, 60Co and 152Eu). The LAC was theoretically calculated for HDPE/micro-MgO composites using XCOM software. A good agreement between the theoretical and experimental results was observed. The comparison between micro and nano-MgO as a filler in HDPE was evaluated. The results proved that the loaded nano-MgO in different proportions of HDPE produced greater attenuation coefficients than its micro counterpart. The addition of nano MgO with different weight percentage led to a significant improvement in the mechanical properties of HDPE, the ultimate force and ultimate stress increased as the concentration of nano MgO increased, and the young modulus of HDPE also increased with increasing concentration of micro and nano MgO.

5.
Appl Radiat Isot ; 197: 110790, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37037134

ABSTRACT

High-density polyethylene (HDPE) was obtained through a compression molding technique, and incorporated with different filler weight fractions (0, 10, 15, 25, and 35%) of bulk WO3, and two different WO3 nanoparticle sizes (45 nm and 24 nm). The radiation attenuation ability of the new category of polymer composite HDPE/WO3 was evaluated using gamma-ray energies ranging from 59.53 up to 1332.5keV of four radioactive sources 241Am, 133Ba, 137Cs, and 60Co. The mass attenuation coefficients µm, the total molecular cross-section σmol, the effective atomic cross-section σatom, the total electronic cross-section σel, the effective atomic number Zeff, electron density Neff, the half value layer (HVL), the tenth value layer (TVL), and the relaxation length were investigated. The obtained results of the gamma-ray attenuation parameters exhibited an outstanding influence of the size and weight fraction of WO3 filler on the gamma-ray shielding ability of the HDPE composite. A significant improvement was detected at low gamma-ray energies. The HVL of the synthesized HDPE composites is compared with that of pure lead as a conventional shielding material. HDPE composite filled with the smaller size of WO3 nanoparticle shows good improvement in the attenuation parameters, which suggests promising applications in radiation protection and gamma-ray shielding.

6.
Materials (Basel) ; 16(5)2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36903170

ABSTRACT

Due to the present industrial world, the risk of radioactivity is notably increasing. Thus, an appropriate shielding material needs to be designed to protect humans and the environment against radiation. In view of this, the present study aims to design new composites of the main matrix of bentonite-gypsum with a low-cost, abundant, and natural matrix. This main matrix was intercalated in various amounts with micro- and nanosized particles of bismuth oxide (Bi2O3) as the filler. Energy dispersive X-ray analysis (EDX) recognized the chemical composition of the prepared specimen. The morphology of the bentonite-gypsum specimen was tested using scanning electron microscopy (SEM). The SEM images showed the uniformity and porosity of a cross-section of samples. The NaI (Tl) scintillation detector was used with four radioactive sources (241Am, 137Cs, 133Ba, and 60Co) of various photon energies. Genie 2000 software was used to determine the area under the peak of the energy spectrum observed in the presence and absence of each specimen. Then, the linear and mass attenuation coefficients were obtained. After comparing the experimental results of the mass attenuation coefficient with the theoretical values from XCOM software, it was found that the experimental results were valid. The radiation shielding parameters were computed, including the mass attenuation coefficients (MAC), half-value layer (HVL), tenth-value layer (TVL), and mean free path (MFP), which are dependent on the linear attenuation coefficient. In addition, the effective atomic number and buildup factors were calculated. The results of all of these parameters provided the same conclusion, which confirms the improvement of the properties of γ-ray shielding materials using a mixture of bentonite and gypsum as the main matrix, which is much better than using bentonite alone. Moreover, bentonite mixed with gypsum is a more economical means of production. Therefore, the investigated bentonite-gypsum materials have potential uses in applications such as gamma-ray shielding materials.

7.
Materials (Basel) ; 16(4)2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36837205

ABSTRACT

In the current study, the gamma-radiation-shielding characteristics of novel gypsum-lime-waste marble-based mortars reinforced with micro-PbO and nano-PbO powders were investigated. In total, seven mortar groups, including a control mortar (named GLM), were prepared. The other groups contained10, 20, and 30 wt.% of both micro-PbO and nano-PbO as a waste marble replacement. This study aimed to explore the effect of particle size and concentrations of PbO powders on the γ-ray-shielding capability of GLM mortars. For this purpose, an HPGe detector and five standard radioactive point sources (241Am, 133Ba, 137Cs, 60Co, and 152Eu) were employed to measure different shielding parameters, including the linear attenuation coefficient (µ), mass attenuation coefficient (µm), mean free path (MFP), half-value layer (HVL), and tenth-value layer (TVL), for the prepared samples in the energy range between 59.53 keV to 1408.01 keV. On the basis of µm values, other significant shielding parameters such as effective atomic number (Zeff), effective electron density (Neff), equivalent atomic number (Zeq), and exposure buildup factor (EBF) were also computed to explore the potential usage of the proposed mortars as radiation protective materials. The results reported that the smallest HVL, TVL, and MPF, as well as the largest attenuation values, were obtained for mortars reinforced by nano-PbO compared to those containing micro-PbO. It can be concluded from the results that the mortar samples containing nano-PbO had a remarkably improved gamma-radiation-shielding ability. Thus, these mortars can be used for radiation shielding on walls in nuclear facilities to reduce the transmitted radiation dose.

8.
Materials (Basel) ; 16(4)2023 Feb 14.
Article in English | MEDLINE | ID: mdl-36837210

ABSTRACT

This study aims to explore the radiation protection properties of white mortars based on white cement as a binder and Bi2O3 micro and nanoparticles in proportions of 15 and 30% by weight as replacement sand. The average particle size of micro- and nano-Bi2O3 was measured using a transmission electron microscope (TEM). The cross-sectional morphology and distribution of Bi2O3 within the samples can be obtained by scanning electron microscopy (SEM), showing that nanoscale Bi2O3 particles have a more homogeneous distribution within the samples than microscale Bi2O3 particles. The shielding parameters of the proposed mortars were measured using the HPGe detector at various γ-ray energies emitted by standard radioactive point sources 241Am, 133Ba, 60Co, 137Cs, and 152Eu. The experimental values of the prepared mortars' mass attenuation coefficients (MAC) match well with those determined theoretically from the XCOM database. Other shielding parameters, including half value layer (HVL), tenth value layer (TVL), mean free path (MFP), effective electron density (Neff), effective atomic number (Zeff), equivalent atomic number (Zeq), and exposure buildup factor (EBF), were also determined at different photon energies to provide more shielding information about the penetration of gamma radiation into the selected mortars. The obtained results indicated that the sample containing 30% by weight of nano Bi2O3 has the largest attenuation coefficient value. Furthermore, the results show that the sample with a high concentration of Bi2O3 has the highest equivalent atomic numbers and the lowest HVL, TVL, MFP, and EBF values. Finally, it can be concluded that Bi2O3 nanoparticles have higher efficiency and protection compared to microparticles, especially at lower gamma-ray energies.

9.
Sci Rep ; 13(1): 210, 2023 Jan 05.
Article in English | MEDLINE | ID: mdl-36604568

ABSTRACT

Reinforced polymer composites are a recent type of advanced shielding material that has been studied experimentally and theoretically. This work described the protection properties of silicon rubber filled with nano and micro tin oxide (II). These shielding materials are evaluated by parameters such as mass attenuation coefficient, linear attenuation coefficient, mean free path, effective atomic number, and buildup factor. The morphology and mechanical properties of silicon rubber, which is reinforced with tin oxide (II) particles in terms of weight fraction and size, have been studied. The results explain that the mass attenuation coefficient increases as tin oxide (II) concentration increases at a particular photon energy. It was found that the shielding properties of nano tin oxide (II) composites are more effective than micro tin oxide (II) composites against gamma rays. The effective atomic number values increase by increasing tin oxide (II) and so on equivalent atomic number. On the other hand, increasing tin oxide (II) weight fraction led to an increase in buildup factor maximum, which proved that tin oxide (II) concentration has significant effectiveness in radiation protection.

10.
Polymers (Basel) ; 14(22)2022 Nov 08.
Article in English | MEDLINE | ID: mdl-36432928

ABSTRACT

The use of radiation is mandatory in modern life, but the harms of radiation cannot be avoided. To minimize the effect of radiation, protection is required for the safety of the environment and human life. Hence, inventing a better shield than a conventional shielding material is the priority of researchers. Due to this reason, this current research deals with an innovative shielding material named EKZ samples having a composition of (epoxy resin (90-40) wt %-kaolin clay (10-25) wt %-ZnO-nano particles (0-35) wt %). The numerous compositional variations of (epoxy resin, kaolin clay, and ZnO-nano particles on the prepared EKZ samples varied the density of the samples from 1.24 to 1.95 g/cm3. The radiation shielding parameter of linear attenuation coefficient (LAC), half value layer (HVL), tenth value layer (TVL), and radiation protection efficiency (RPE) were measured to evaluate the radiation diffusion efficiency of newly made EKZ samples. These radiation shielding parameters were measured with the help of the HPGe detector utilizing the three-point sources (Am-241, Cs-137, and Co-60). The obtained results exposed that the value of linear attenuation coefficient (LAC) and radiation protection efficiency (RPE) was maximum, yet the value of half value layer (HVL), and tenth value layer (TVL), were minimum due to the greater amount of kaolin clay and ZnO-nanoparticles, whereas the amount of epoxy resin was lesser. In addition, it has been clear that as-prepared EKZ samples are suitable for low-dose shielding applications as well as EKZ-35 showed a better shielding ability.

11.
Sci Rep ; 12(1): 15722, 2022 09 20.
Article in English | MEDLINE | ID: mdl-36127499

ABSTRACT

In this work, morphological and attenuation parameters of gamma ray protection were studied. Dimethyl polysiloxane (Silicon Rubber) Mixed with micro-size and nano-size lead oxide particles at different weight percentage were prepared. The morphological structure of PbO/SR composites was investigated by SEM test, according to SEM images the nano PbO particles are more uniform micro PbO particles. The radiation attenuation test was carried out using 3" × 3" NaI (TI) detector for (Am-241), (Cs-137), (Co-60), (Ba-133), and (Eu-152). The effect on attenuation property of SR-PbO shown that the increase of PbO filler significantly increases the linear attenuation coefficient and improve the other radiation protection parameters especially at low gamma energy. It's found that a significant agreement between the experimental result and theoretical result from Xcom program. In this study it's found matrix filled with nano-PbO have higher gamma shielding ability compared to micro-PbO matrix at the same filler concentration. It can say that SR-nano PbO has a higher radiation protection than SR-micro PbO compositions.


Subject(s)
Nanoparticles , Radiation Protection , Cesium Radioisotopes , Dimethylpolysiloxanes , Nanoparticles/chemistry , Radiation Protection/methods , Rubber , Silicon
12.
Appl Radiat Isot ; 163: 109139, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32561067

ABSTRACT

Low cost scintillation detectors as compared with HPGe detectors are considered to be one of most important radiation detection tools. Therefore, these detectors can be manufactured in different shapes and work at room temperature without any cooling systems, which added an extra advantage to it. This work presents a study of a cubic detector with a rectangular cavity in different experimental setup geometries, using standard point-like gamma-ray sources, where the efficiency of the detector in these geometries was the target to be studied. According to this aim, the data from the experimental measurements was used to determine the detector efficiency. An analytical calculation of the detector efficiency was done by using a new mathematical expression, this mathematical expression depends on the efficiency transfer technique and effective solid angle calculations. To support the mathematical model, the source-to-detector arrangement was simulated by Geant4 Monte Carlo code. All the compared efficiency results were found to be promising and trusted based on the calculated deviation percentages.

13.
Rev Sci Instrum ; 87(11): 115105, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910417

ABSTRACT

Scintillation crystals are usually used for detection of energetic photons at room temperature in high energy and nuclear physics research, non-destructive analysis of materials testing, safeguards, nuclear treaty verification, geological exploration, and medical imaging. Therefore, new designs and construction of radioactive beam facilities are coming on-line with these science brunches. A good number of researchers are investigating the efficiency of the γ-ray detectors to improve the models and techniques used in order to deal with the most pressing problems in physics research today. In the present work, a new integrative and uncomplicated numerical simulation method (NSM) is used to compute the full-energy (photo) peak efficiency of a regular hexagonal prism NaI(Tl) gamma-ray detector using radioactive point sources situated non-axial within its front surface boundaries. This simulation method is based on the efficiency transfer method. Most of the mathematical formulas in this work are derived analytically and solved numerically. The main core of the NSM is the calculation of the effective solid angle for radioactive point sources, which are situated non-axially at different distances from the front surface of the detector. The attenuation of the γ-rays through the detector's material and any other materials in-between the source and the detector is taken into account. A remarkable agreement between the experimental and calculated by present formalism results has been observed.

14.
Rev Sci Instrum ; 87(2): 025112, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931896

ABSTRACT

Gamma-ray detectors are widely used in many fields like environmental measurements, medicine, space science, and industry, where the detector geometrical, total, photopeak efficiencies and peak-to-total ratio could be required. The calculation of the detector efficiency depends mainly on the value of the geometrical efficiency, which depends on the solid angle subtended by the source-detector system. The present work introduces a direct analytical method to calculate the geometrical and total efficiencies of CdZnTe gamma-ray detector using off-axis isotropic radiating γ-ray [point, disk, and cylindrical] sources. To test the validity of the present work, the results are compared with some published data and also to prove how much it is important to determine the efficiency of difficult gamma-ray detection arrangement.

15.
Radiat Prot Dosimetry ; 156(1): 109-17, 2013.
Article in English | MEDLINE | ID: mdl-23509395

ABSTRACT

A new theoretical approach was used to calibrate and calculate the full-energy peak efficiency of the NaI (Tl) detectors based on the direct statistical method proposed by Selim and Abbas for cylindrical detectors. In addition, the self-attenuation of the source matrix, the attenuation by the source container and the detector housing materials were considered in the mathematical treatment. Results were compared with those measured by a cylindrical NaI (Tl) detector with resolution (FWHM) at 662 keV equal to 7.5 %. (152)Eu aqueous radioactive spherical sources covering the energy range from 121 to 1408 keV were used. In comparison, the calculated and the measured full-energy peak efficiency values were in good agreement.


Subject(s)
Radiometry/methods , Sodium Iodide/chemistry , Algorithms , Calibration , Equipment Design , Europium/analysis , Models, Theoretical , Photons , Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Radiometry/instrumentation , Thallium/chemistry
16.
Appl Radiat Isot ; 70(12): 2661-8, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23023386

ABSTRACT

To calibrate the co-axial HPGe semiconductor detectors, we introduce a new theoretical approach based on the Direct Statistical method proposed by Selim and Abbas (1995, 1996) to calculate the full-energy peak efficiency for cylindrical detectors. The present method depends on the accurate analytical calculation of the average path length covered by the photon inside the detector active volume and the geometrical solid angle Ω, to obtain a simple formula for the efficiency. In addition, the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius), the attenuation factors of the source container and the detector housing materials are also treated by calculating the average path length within these materials. (152)Eu aqueous radioactive sources covering the energy range from 121 to 1408 keV were used. Remarkable agreement between the measured and the calculated efficiencies was achieved with discrepancies less than 2%.

SELECTION OF CITATIONS
SEARCH DETAIL
...