Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Colorectal Dis ; 38(1): 127, 2023 May 13.
Article in English | MEDLINE | ID: mdl-37173554

ABSTRACT

PURPOSE: C-REX is a novel instrument for creating stapleless colorectal anastomosis by compression. The aim of this study was to evaluate the feasibility and effectiveness of C-REX in open and laparoscopic high anterior resections. METHODS: A prospective clinical safety study on 21 patients reconstructed with C-REX colorectal anastomosis following high anterior resection of the sigmoid colon using two different devices for intraabdominal (n = 6) or transanal (n = 15) placement of the anastomotic rings. Any signs of complications were prospectively monitored by a predefined protocol. Anastomotic contact pressure (ACP) was measured via a catheter-based system, and time for evacuation of the anastomotic rings by the natural route was noted. Blood samples were collected daily, and flexible endoscopy was performed postoperatively to examine macroscopic appearance of the anastomoses. RESULTS: One of six patients operated with the intraabdominal anastomosis technique with an ACP of 50 mBar had to be reoperated because of anastomotic leakage. None of the 15 patients operated with the transanal technique (5 open and 10 laparoscopic procedures) had anastomotic complications, and their ACP ranged between 145 and 300 mBar. C-REX rings were uneventfully expelled by the natural route in all patients after a median of 10 days. Flexible endoscopy showed well-healed anastomoses without stenosis in 17 patients and a moderate subclinical stricture in one patient. CONCLUSION: These results indicate that the novel transanal C-REX device is a feasible and effective method for colorectal anastomosis following high anterior resections, irrespective of open or laparoscopic approach. Moreover, C-REX allows measurement of intraoperative ACP and thereby a quantitative evaluation of the anastomotic integrity.


Subject(s)
Anastomotic Leak , Colorectal Neoplasms , Humans , Prospective Studies , Anastomosis, Surgical/adverse effects , Anastomosis, Surgical/methods , Anastomotic Leak/etiology , Anastomotic Leak/surgery , Rectum/surgery , Colorectal Neoplasms/surgery
2.
BMC Res Notes ; 10(1): 89, 2017 Feb 08.
Article in English | MEDLINE | ID: mdl-28179015

ABSTRACT

BACKGROUND: Colorectal cancer is common in humans where treatment involves surgical removal of the cancerous part of the intestines. In the anastomosis procedure a purse-string suture may be time consuming to perform. The aim was to replace the purse-string suture, to develop and test a self-locking loop for temporary sealing of the lumen in colon anastomosis. METHODS: A new device, a flexible band with a locking mechanism was constructed, the I-Tie®. Small protrusions, designed for increased friction between device and tissue, were added to one side of the flexible band in order to enhance the grip at closure of the loop around tissue. The device was initially tested in vitro on pig intestines. In an in vivo study, the short-term implant was tested in a new suture-free method, CREX, and with traditional circular staplers for colonic anastomosis. Ten female pigs of approximately 50 kg were used in the in vivo test. The self-locking device was used for closure of the lumen around anvils in CREX (n = 5), and around anvil in traditional circular stapler anastomosis (n = 5). Two self-locking devices were used in each animal. RESULTS: The self-locking device could close the lumen of colon around the anvil and trocar. Subjectively, the device achieved a tight closure of the colon and did not interfere with the anastomosis techniques. CONCLUSIONS: The technology was perceived as potentially timesaving and easy to use. We conclude the device may be an alternative to the traditional purse-string suture for temporary closure of the colon lumen in colon anastomosis.


Subject(s)
Anastomosis, Surgical/instrumentation , Colectomy/instrumentation , Colon/surgery , Suture Techniques , Anastomosis, Surgical/methods , Animals , Colectomy/methods , Feasibility Studies , Female , Surgical Instruments , Sutures , Swine
3.
Int J Colorectal Dis ; 30(7): 969-75, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25989929

ABSTRACT

BACKGROUND: Compression anastomotic ring-locking procedure (CARP) is a novel procedure for creating colonic anastomoses. The surgical procedure allows perioperative quantification of the compression pressure between the intestinal ends within the anastomosis and postoperative monitoring of the anastomotic integrity. We have recently shown that CARP is a safe and effective method for colonic anastomoses in pigs, and the purpose of the present study was to evaluate CARP for colonic anastomoses in humans. MATERIALS AND METHODS: This is a prospective study on 25 patients undergoing elective left-sided colonic resection. Time for evacuation of the anastomotic rings, perioperative compression pressure, and adverse effects were recorded. Postoperative blood samples were collected daily, and flexible sigmoidoscopy was performed 8-12 weeks after surgery to examine the anastomoses. RESULTS: Fourteen out of 25 patients underwent CARP. CARP was not used in 11 patients due to advanced tumor disease (two cases) and size restrictions (nine cases). No case of anastomotic leakage, bowel obstruction, or stenosis formation was observed. No device-related perioperative adverse events were noted. The surgical device evacuated spontaneously in all patients by the natural route after a median of 10 days. Perioperative compression pressure ranged between 85 and 280 mBar (median 130 mBar). Flexible sigmoidoscopy revealed smooth anastomoses without signs of pathological inflammation or stenosis in all cases. CONCLUSION: Our results indicate that the novel suture-less CARP is a safe and effective method for creating colonic anastomoses. Further studies are warranted in larger patient populations to compare CARP head-on-head with stapled and/or hand-sewn colonic anastomoses.


Subject(s)
Anastomosis, Surgical/methods , Digestive System Surgical Procedures/methods , Intestines/surgery , Aged , Anastomosis, Surgical/instrumentation , Digestive System Surgical Procedures/instrumentation , Female , Humans , Leukocyte Count , Male , Middle Aged , Postoperative Care , Sigmoidoscopy
4.
Eur Surg Res ; 54(3-4): 139-47, 2015.
Article in English | MEDLINE | ID: mdl-25531546

ABSTRACT

BACKGROUND/AIM: Compression anastomoses might represent an improvement over traditional hand-sewn or stapled techniques. Herein, we describe a novel concept of sutureless colonic anastomosis named compression anastomotic ring-locking procedure (CARP). MATERIALS AND METHODS: The surgical device consists of two anastomotic rings and their associated helping tools, facilitating the placement of the rings into the intestinal ends. Furthermore, four catheters are connected to the surgical device, allowing the evaluation of the anastomosis during and after surgery. A total of 31 pigs underwent a low colocolic anastomosis using the anastomotic rings. The compression pressure was measured perioperatively and up to 96 h after surgery. Anastomotic integrity and morphology were analyzed by use of radiology and histology, respectively. A long-term follow-up was conducted in a subgroup of pigs up to 108 days after surgery when the bursting pressure and stricture formation were examined. RESULTS: All animals recovered uneventfully, and macroscopic examination revealed intact anastomoses without signs of pathological inflammation or adhesions. The perioperative compression pressure was inversely proportional to the gap size between the anastomotic rings. For example, an anastomotic gap of 1.5 mm created a colonic anastomosis with a perioperative compression pressure of 91 mbar, which remained constant for up to 48 h and resulted in a markedly increased compression pressure. Contrast infusion via the catheters effectively visualized the anastomoses, and no leakage was detected within the study. The surgical device was spontaneously evacuated from the intestines within 6 days after surgery. Histology showed collagen bridging of the anastomoses already 72 h after surgery. Long-term follow-up (54-108 days) revealed no stricture formation in the anastomoses, and the bursting pressure ranged from 120 to 235 mbar. The majority of bursts (10/12) occurred distant from the anastomoses. CONCLUSION: We conclude that the surgical device associated to CARP is safe and efficient for creating colonic anastomoses. Further studies in patients undergoing colorectal surgery are warranted.


Subject(s)
Colon/surgery , Anastomosis, Surgical/instrumentation , Anastomosis, Surgical/methods , Animals , Colectomy/instrumentation , Colectomy/methods , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...