1.
Isotopes Environ Health Stud ; 60(1): 74-89, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37975234

ABSTRACT

Advanced computational fluid dynamics (CFD) simulations are essential for predicting airflow in ventilated spaces and assessing indoor air quality. In this study, a focus was set on techniques for the reduction of indoor radon-222 activity concentration [Rn], and it is demonstrated how true-to-scale 3D CFD models can predict the evolution of complex ventilation experiments. A series of ventilation experiments in an unoccupied flat on the ground floor of a residential block in Bad Schlema (Saxony, Germany) were performed. Specifically, the 'Cross-ventilation 100 %' experiment resulted in room-specific [Rn] reductions from ∼3000 to ∼300 Bq m-3. We quantitatively interpreted the results of the ventilation experiment using a CFD model with a k-ϵ turbulent stationary flow model characterised by the used decentralised ventilation system. The model was coupled with a transient transport model simulating indoor [Rn]. In a first approach, the model overestimated the decrease in the starting of the experiment and the steady state. Adjusting the model parameters inflowing radon and inlet velocity the model results are in a good agreement with the experimental values. In conclusion, this paper demonstrates the potential of CFD modelling as a suitable tool in evaluating and optimising ventilation systems for an effective reduction of elevated [Rn].


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Hydrodynamics , Models, Theoretical , Radon/analysis , Air Pollution, Indoor/analysis , Air Pollutants, Radioactive/analysis , Housing
2.
Isotopes Environ Health Stud ; 58(2): 195-213, 2022 May.
Article in English | MEDLINE | ID: mdl-35266853

ABSTRACT

ABSTRACTRadon-222 contributes to half of the natural radiation exposure of humans and is one of the main causes of lung cancer. Of particular importance for humans is the exposure to radon-222 indoors, which enters living and working areas from the soil air, e.g. through cracks in the foundations of buildings. An easy and efficient way to minimise indoor radon in dwellings can be achieved through ventilation. How meteorological parameters and the geological background can influence ventilation efficiency in reducing indoor radon has not yet been fully investigated. Therefore, a decentralised ventilation system was installed in an unoccupied flat located in a former uranium mining region to analyse the effect of already existing ventilation modes on indoor radon activity concentration. It is aimed to assess 22 different ventilation experiments that were performed within the time period of one year. Even with a strong seasonal trend with significantly lower indoor radon activity concentrations in summer compared to winter, the decentralised ventilation system was able to reduce indoor radon by up to 83 %. Thereby, strong dependencies on the experimental parameters such as ventilation type or performance level of the fans were found.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Air Pollution, Indoor/prevention & control , Housing , Humans , Radon/analysis
3.
J Radiol Prot ; 41(3)2021 Aug 18.
Article in English | MEDLINE | ID: mdl-33910183

ABSTRACT

The new German Radiation Protection Act (StrlSchG) of 31 December 2018 established a reference value of 300 Bq m-3for the annual average radon activity concentration in buildings with recreation and living rooms, as well as in workplaces. It is expected that the reference value will be exceeded in a vast number of buildings throughout Germany and that radon protection measures will become indispensable. A simple and inexpensive radon protection measure for existing buildings is ventilation. In the scope of a joint project, ventilation systems with zone control and heat recovery are to be extended by the control parameter radon activity concentration. A highly sensitive, miniaturized radon monitor will be developed for this purpose, which can be integrated wirelessly into ventilation systems. Radon measurements were carried out in 13 apartments of an unoccupied heated apartment block in Germany over a period of three weeks in the wintertime. High radon activity concentrations were found on all three floors. The maximum values were 14000 Bq m-3on the first floor, 6000 Bq m-3on the second floor, and 2000 Bq m-3on the third floor. Ventilation experiments were carried out in an apartment with high radon activity concentration. Two decentralized ventilation systems with heat recovery were installed in each of the two opposite outside walls. The controlling device of the system was activated wirelessly depending on the radon activity concentration. The radon activity concentration was reduced from 8000 Bq m-3to 800 Bq m-3in a first experiment in the living room.


Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radiation Protection , Radon , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Housing , Radon/analysis , Ventilation , Workplace