1.
Clin Chem ; 53(7): 1370-2, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17495022

ABSTRACT

BACKGROUND: There is considerable disagreement regarding the concentration of glucose in tears and its relationship to the concentration in blood. Improved sampling and analysis methods may resolve these discrepancies and possibly provide a basis for in situ tear glucose sensors. METHODS: We used liquid chromatography (LC) with electrospray ionization mass spectrometry (ESI-MS) to determine glucose in 1-muL tear fluid samples obtained from 25 fasting study participants. Tear fluid was collected with microcapillaries and a slitlamp microscope. RESULTS: The median (range) of fasting tear glucose concentrations was 28 (7-161) micromol/L or 0.50 (0.13-2.90) mg/dL. The SD of tear glucose measurements for individuals varied linearly with the mean tear glucose concentration and was approximately half of the mean. We found no significant difference in tear glucose concentrations between contact lens users and nonusers (P = 0.715). We observed significant correlations between fasting blood and tear glucose concentrations (R = 0.50, P = 0.01). CONCLUSIONS: Our tear fluid collection and analysis method enables reliable measurement of equilibrium, fasting tear glucose concentrations. These concentrations are lower than those previously reported for nondiabetic persons. Larger population studies are required to determine correlations between blood and tear glucose concentrations and to determine the utility of contact lens-based sensors for the monitoring of diabetes. Our methods are applicable for study of other tear fluid analytes and may prove useful for monitoring other disease states.


Subject(s)
Glucose/analysis , Tears/chemistry , Adolescent , Adult , Blood Glucose/analysis , Contact Lenses , Fasting , Humans , Middle Aged , Reference Values , Spectrometry, Mass, Electrospray Ionization
2.
J Am Soc Mass Spectrom ; 18(2): 332-6, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17084090

ABSTRACT

We have developed a mass spectrometry-based method that allows one to accurately determine the glucose concentration of tear fluid. We used a 1 microL micro-capillary to collect tear fluid from the tear meniscus with minimal irritation of the eye. We analyzed the 1 muL volume of collected tear fluid with liquid-chromatography electrospray ionization mass spectrometry with the use of D-glucose-6,6-d2 as an internal standard. Repeated measurements and a recovery experiment on pooled, onion-induced tears showed that the analysis of the glucose in tears was precise (4% relative standard deviation) and provided 100% recovery. We found the tear glucose concentration of one fasting nondiabetic subject to be 13 to 51 microM while the onion-induced tear glucose concentration of a different nondiabetic subject to be 211 to 256 microM.


Subject(s)
Glucose/analysis , Spectrometry, Mass, Electrospray Ionization , Tears/chemistry , Chromatography, High Pressure Liquid , Glucose/metabolism , Humans , Reference Values , Tears/metabolism