Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Sci Rep ; 13(1): 18788, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37914762

ABSTRACT

A fast and reliable range monitoring method is required to take full advantage of the high linear energy transfer provided by therapeutic ion beams like carbon and oxygen while minimizing damage to healthy tissue due to range uncertainties. Quasi-real-time range monitoring using in-beam positron emission tomography (PET) with therapeutic beams of positron-emitters of carbon and oxygen is a promising approach. The number of implanted ions and the time required for an unambiguous range verification are decisive factors for choosing a candidate isotope. An experimental study was performed at the FRS fragment-separator of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany, to investigate the evolution of positron annihilation activity profiles during the implantation of [Formula: see text]O and [Formula: see text]O ion beams in a PMMA phantom. The positron activity profile was imaged by a dual-panel version of a Siemens Biograph mCT PET scanner. Results from a similar experiment using ion beams of carbon positron-emitters [Formula: see text]C and [Formula: see text]C performed at the same experimental setup were used for comparison. Owing to their shorter half-lives, the number of implanted ions required for a precise positron annihilation activity peak determination is lower for [Formula: see text]C compared to [Formula: see text]C and likewise for [Formula: see text]O compared to [Formula: see text]O, but their lower production cross-sections make it difficult to produce them at therapeutically relevant intensities. With a similar production cross-section and a 10 times shorter half-life than [Formula: see text]C, [Formula: see text]O provides a faster conclusive positron annihilation activity peak position determination for a lower number of implanted ions compared to [Formula: see text]C. A figure of merit formulation was developed for the quantitative comparison of therapy-relevant positron-emitting beams in the context of quasi-real-time beam monitoring. In conclusion, this study demonstrates that among the positron emitters of carbon and oxygen, [Formula: see text]O is the most feasible candidate for quasi-real-time range monitoring by in-beam PET that can be produced at therapeutically relevant intensities. Additionally, this study demonstrated that the in-flight production and separation method can produce beams of therapeutic quality, in terms of purity, energy, and energy spread.

2.
Nucl Instrum Methods Phys Res B ; 541: 114-116, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37265512

ABSTRACT

The FRagment Separator FRS at GSI is a versatile spectrometer and separator for experiments with relativistic in-flight separated short-lived exotic beams. One branch of the FRS is connected to the target hall where the bio-medical cave (Cave M) is located. Recently a joint activity between the experimental groups of the FRS and the biophysics at the GSI and Department of physics at LMU was started to perform biomedical experiments relevant for hadron therapy with positron emitting carbon and oxygen beams. This paper presents the new ion-optical mode and commissioning results of the FRS-Cave M branch where positron emitting 15O-ions were provided to the medical cave for the first time. An overall conversion efficiency of 2.9±0.2×10-4 15O fragments per primary 16O ion accelerated in the synchrotron SIS18 was reached.

3.
Phys Med Biol ; 68(1)2022 12 19.
Article in English | MEDLINE | ID: mdl-36533621

ABSTRACT

Objective. Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable12C ions, the positron emitters10,11C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam.Approach.An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner.Main results.High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes11C and10C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 107ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for10C,11C and12C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from11C to10C than when going from12C to11C. The much better precision for10C is due to its much shorter half-life, which, contrary to the case of11C, also enables to include the in-spill data in the image formation.Significance. Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics.


Subject(s)
Positron-Emission Tomography , Positron-Emission Tomography/methods , Phantoms, Imaging , Half-Life , Germany
4.
Phys Med Biol ; 66(23)2021 11 29.
Article in English | MEDLINE | ID: mdl-34706355

ABSTRACT

This work provides a quantitative assessment of helium ion CT (HeCT) for particle therapy treatment planning. For the first time, HeCT based range prediction accuracy in a heterogeneous tissue phantom is presented and compared to single-energy x-ray CT (SECT), dual-energy x-ray CT (DECT) and proton CT (pCT). HeCT and pCT scans were acquired using the US pCT collaboration prototype particle CT scanner at the Heidelberg Ion-Beam Therapy Center. SECT and DECT scans were done with a Siemens Somatom Definition Flash and converted to RSP. A Catphan CTP404 module was used to study the RSP accuracy of HeCT. A custom phantom of 20 cm diameter containing several tissue equivalent plastic cubes was used to assess the spatial resolution of HeCT and compare it to DECT. A clinically realistic heterogeneous tissue phantom was constructed using cranial slices from a pig head placed inside a cylindrical phantom (ø150 mm). A proton beam (84.67 mm range) depth-dose measurement was acquired using a stack of GafchromicTM EBT-XD films in a central dosimetry insert in the phantom. CT scans of the phantom were acquired with each modality, and proton depth-dose estimates were simulated based on the reconstructions. The RSP accuracy of HeCT for the plastic phantom was found to be 0.3 ± 0.1%. The spatial resolution for HeCT of the cube phantom was 5.9 ± 0.4 lp cm-1for central, and 7.6 ± 0.8 lp cm-1for peripheral cubes, comparable to DECT spatial resolution (7.7 ± 0.3 lp cm-1and 7.4 ± 0.2 lp cm-1, respectively). For the pig head, HeCT, SECT, DECT and pCT predicted range accuracy was 0.25%, -1.40%, -0.45% and 0.39%, respectively. In this study, HeCT acquired with a prototype system showed potential for particle therapy treatment planning, offering RSP accuracy, spatial resolution, and range prediction accuracy comparable to that achieved with a commercial DECT scanner. Still, technical improvements of HeCT are needed to enable clinical implementation.


Subject(s)
Helium , Protons , Animals , Helium/therapeutic use , Phantoms, Imaging , Plastics , Swine , Tomography, X-Ray Computed , X-Rays
5.
J Phys Chem B ; 124(46): 10365-10373, 2020 11 19.
Article in English | MEDLINE | ID: mdl-33153262

ABSTRACT

Melanin, an important class of natural pigment found in the human body, has stood out as a promising bioelectronic material due to its rather unique collection of electrical properties and biocompatibility. Among the available melanin derivatives, the sulfonated form has proven to not only be able to produce homogeneous device quality thin films with excellent adhesion, even on hydrophobic surfaces, but also to act as an ion to electron transducing element. It has recently been shown that the transport physics (and dominant carrier generation) may be related to a semiquinone free radical species in these materials. Hence, a better understanding of the paramagnetic properties of sulfonated derivatives could shed light on their charge transport behavior and thus enable improvement in regard to use in bioelectronics. Motivated by this question, in this work, different sulfonated melanin derivatives were investigated by hydration-controlled, continuous-wave X-band electron paramagnetic resonance spectroscopy and electronic structure calculations. Our results show that sulfonated melanin behaves similarly to non-functionalized melanin, but demonstrates a less pronounced response to humidity vis-à-vis standard melanin. We thus speculate on the structural and charge transport behavior in light of these differences with a view to further engineering structure-property relationships.


Subject(s)
Electrons , Melanins , Electron Spin Resonance Spectroscopy , Free Radicals , Humans
6.
Phys Med Biol ; 65(21): 215012, 2020 11 06.
Article in English | MEDLINE | ID: mdl-32610300

ABSTRACT

Intensity modulated particle therapy (IMPT) with carbon ions can generate highly conformal treatment plans; however, IMPT is limited in robustness against range and positioning uncertainty. This is particularly true for moving targets, even though all motion states of a 4DCT are considered in 4D-IMPT. Here, we expand 4D-IMPT to include robust non-linear RBE-weighted optimization to explore its potential in improving plan robustness and sparing critical organs. In this study, robust 4D-optimization-based on worst-case optimization on 9 scenarios-was compared to conventional 4D-optimization with PTV margins using 4D dose calculation and robustness analysis for 21 uncertainty scenarios. Slice-by-slice rescanning was used for motion mitigation. Both 4D-optimization strategies were tested on a cohort of 8 multi-lesion lung cancer patients with the goal of prioritizing OAR sparing in a hypofractionated treatment plan. Planning objectives were to keep the OAR volume doses below corresponding limits while simultaneously achieve CTV coverage with D95% ≥ 95 %. For the conventional plans, average D95% was at 98.7% which fulfilled the target objective in 83.2% of scenarios. For the robust plans, average D95% was reduced to 97.6% which still fulfilled the target objective in 80.7% of cases, but led to significantly improved overall OAR sparing: Volume doses were below the limits in 96.2% of cases for the conventional and 99.5% for the robust plans. When considering the particularly critical smaller airways only, fulfillment rates could be increased from 76.2% to 96% for the robust plans. This study has shown that plan robustness of 4D-IMPT could be improved by using robust 4D-optimization, offering greater control over uncertainties in the actual delivered dose. In some cases, this required sacrificing target coverage for the benefit of better OAR sparing.


Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/radiotherapy , Four-Dimensional Computed Tomography , Heavy Ion Radiotherapy , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Carcinoma, Non-Small-Cell Lung/pathology , Humans , Lung Neoplasms/pathology , Neoplasm Staging , Radiotherapy Dosage , Uncertainty
7.
BMC Pregnancy Childbirth ; 20(1): 117, 2020 Feb 19.
Article in English | MEDLINE | ID: mdl-32075598

ABSTRACT

BACKGROUND: Pelvic floor muscles (PFM) and rectus abdominis muscles (RAM) of pregnant diabetic rats exhibit atrophy, co-localization of fast and slow fibers and an increased collagen type I/III ratio. However, the role of similar PFM or RAM hyperglycemic-related myopathy in women with gestational diabetes mellitus (GDM) remains poorly investigated. This study aims to assess the frequency of pelvic floor muscle disorders and pregnancy-specific urinary incontinence (PS-UI) 12 months after the Cesarean (C) section in women with GDM. Specifically, differences in PFM/RAM hyperglycemic myopathy will be evaluated. METHODS: The Diamater is an ongoing cohort study of four groups of 59 pregnant women each from the Perinatal Diabetes Research Centre (PDRC), Botucatu Medical School (FMB)-UNESP (São Paulo State University), Brazil. Diagnosis of GDM and PS-UI will be made at 24-26 weeks, with a follow-up at 34-38 weeks of gestation. Inclusion in the study will occur at the time of C-section, and patients will be followed at 24-48 h, 6 weeks and 6 and 12 months postpartum. Study groups will be classified as (1) GDM plus PS-UI; (2) GDM without PS-UI; (3) Non-GDM plus PS-UI; and (4) Non-GDM without PS-UI. We will analyze relationships between GDM, PS-UI and hyperglycemic myopathy at 12 months after C-section. The mediator variables to be evaluated include digital palpation, vaginal squeeze pressure, 3D pelvic floor ultrasound, and 3D RAM ultrasound. RAM samples obtained during C-section will be analyzed for ex-vivo contractility, morphological, molecular and OMICS profiles to further characterize the hyperglycemic myopathy. Additional variables to be evaluated include maternal age, socioeconomic status, educational level, ethnicity, body mass index, weight gain during pregnancy, quality of glycemic control and insulin therapy. DISCUSSION: To our knowledge, this will be the first study to provide data on the prevalence of PS-UI and RAM and PFM physical and biomolecular muscle profiles after C-section in mothers with GDM. The longitudinal design allows for the assessment of cause-effect relationships between GDM, PS-UI, and PFMs and RAMs myopathy. The findings may reveal previously undetermined consequences of GDM.


Subject(s)
Diabetes, Gestational/physiopathology , Muscular Diseases/physiopathology , Urinary Incontinence/physiopathology , Adult , Brazil , Cesarean Section , Cohort Studies , Female , Gestational Age , Gestational Weight Gain , Humans , Maternal Age , Muscle Contraction/physiology , Muscle Strength/physiology , Palpation , Pelvic Floor/physiopathology , Postpartum Period , Pregnancy , Rectus Abdominis/physiopathology , Vagina
8.
Phys Med Biol ; 65(5): 055002, 2020 02 28.
Article in English | MEDLINE | ID: mdl-31962302

ABSTRACT

Recently, it has been proposed that a mixed helium/carbon beam could be used for online monitoring in carbon ion beam therapy. Fully stripped, the two ion species exhibit approximately the same mass/charge ratio and hence could potentially be accelerated simultaneously in a synchrotron to the same energy per nucleon. At the same energy per nucleon, helium ions have about three times the range of carbon ions, which could allow for simultaneous use of the carbon ion beam for treatment and the helium ion beam for imaging. In this work, measurements and simulations of PMMA phantoms as well as anthropomorphic phantoms irradiated sequentially with a helium ion and a carbon ion beam at equal energy per nucleon are presented. The range of the primary helium ion beam and the fragment tail of the carbon ion beam exiting the phantoms were detected using a novel range telescope made of thin plastic scintillator sheets read out by a flat-panel CMOS sensor. A 10:1 carbon to helium mixing ratio is used, generating a helium signal well above the carbon fragment background while adding little to the dose delivered to the patient. The range modulation of a narrow air gap of 1 mm thickness in the PMMA phantom that affects less than a quarter of the particles in a pencil beam were detected, demonstrating the achievable relative sensitivity of the presented method. Using two anthropomorphic pelvis phantoms it is shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable changes in the helium/carbon beam exiting the phantom. The future prospects and limitations of the helium/carbon mixing as well as its technical feasibility are discussed.


Subject(s)
Heavy Ion Radiotherapy/methods , Helium/therapeutic use , Carbon/therapeutic use , Heavy Ion Radiotherapy/instrumentation , Humans , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Telescopes
9.
Sci Rep ; 6: 27651, 2016 06 10.
Article in English | MEDLINE | ID: mdl-27282667

ABSTRACT

The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. Tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.


Subject(s)
Protons , Tomography/methods , Animals , Chickens , Humans , Microscopy/methods , Microscopy/standards , Phantoms, Imaging , Tomography/standards , Zebrafish
10.
Med Phys ; 41(7): 071703, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24989372

ABSTRACT

PURPOSE: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. METHODS: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. RESULTS: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. CONCLUSIONS: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min.


Subject(s)
Algorithms , Ions/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiotherapy Dosage , Time Factors
11.
J Phys Chem A ; 118(21): 3717-3725, 2014 May 29.
Article in English | MEDLINE | ID: mdl-24810016

ABSTRACT

Iridium-based compounds are materials of great interest in the production of highly efficient organic light emitting diodes and several other applications. However, these organometallic compounds present relative low stability due to photodegradation processes still not well understood. In this work we investigated paramagnetic states induced by UV photoexcitation on iridium(III) bis[(4,6-fluorophenyl)-pyridinato-N,C2']picolinate (FIrpic) and iridium(III)-tris(2-phenylpyridine) (Ir(ppy)3) complexes dispersed in different polymeric matrices by electron spin resonance (ESR). Photogenerated charged states with relatively strong hyperfine interactions were observed and attributed to matrix/complex charge-transfer processes. Measurements of the signal amplitude decay after photoexcitation interruption were performed as a function of temperature. The photoinduced centers are thermally activated with energy barrier between 0.3 and 0.6 eV. Electronic structure calculations suggest that the signals observed by ESR are associated with metastable negatively charged Ir complexes distorted structures.

12.
Med Phys ; 41(4): 041708, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24694128

ABSTRACT

PURPOSE: The use of motion mitigation techniques such as tracking and gating in particle therapy requires real-time knowledge of tumor position with millimeter precision. The aim of this phantom-based study was to evaluate the option of diagnostic ultrasound (US) imaging (sonography) as real-time motion detection method for scanned heavy ion beam irradiation of moving targets. METHODS: For this pilot experiment, a tumor surrogate was moved inside a water bath along two-dimensional trajectories. A rubber ball was used for this purpose. This ball was moved by a robotic arm in two dimensions lateral to the heavy ion beam. Trajectories having a period of 3 s and peak to peak amplitude of 20 mm were used. Square radiation fields of[Formula: see text] were irradiated on radiosensitive films with a 200 MeV/u beam of calcium ions having a FWHM of 6 mm. Pencil beam scanning and beam tracking were employed. The films were attached on the robotic arm and thus moved with the rubber ball. The position of the rubber ball was continuously measured by a US tracking system (Mediri GmbH, Heidelberg) and sent to the GSI therapy control system (TCS). This position was used as tracking vector. Position reconstruction from the US tracking system and data communication introduced a delay leading to a position error of several millimeters. An artificial neural network (ANN) was implemented in the TCS to predict motion from US measurements and thus to compensate for the delay. RESULTS: Using ANN delay compensation and large motion amplitudes, the authors could produce irradiation patterns with a few percent inhomogeneity and about 1 mm geometrical conformity. CONCLUSIONS: This pilot experiment suggests that diagnostic US should be further investigated as dose-free, high frame-rate, and model-independent motion detection method for scanning heavy ion beam irradiation of moving targets.


Subject(s)
Heavy Ion Radiotherapy/methods , Movement , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Neoplasms/physiopathology , Neural Networks, Computer , Ultrasonography
13.
Osteoporos Int ; 24(12): 2971-81, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23740422

ABSTRACT

UNLABELLED: Changes of the bone formation marker PINP correlated positively with improvements in vertebral strength in men with glucocorticoid-induced osteoporosis (GIO) who received 18-month treatment with teriparatide, but not with risedronate. These results support the use of PINP as a surrogate marker of bone strength in GIO patients treated with teriparatide. INTRODUCTION: To investigate the correlations between biochemical markers of bone turnover and vertebral strength estimated by finite element analysis (FEA) in men with GIO. METHODS: A total of 92 men with GIO were included in an 18-month, randomized, open-label trial of teriparatide (20 µg/day, n = 45) and risedronate (35 mg/week, n = 47). High-resolution quantitative computed tomography images of the 12th thoracic vertebra obtained at baseline, 6 and 18 months were converted into digital nonlinear FE models and subjected to anterior bending, axial compression and torsion. Stiffness and strength were computed for each model and loading mode. Serum biochemical markers of bone formation (amino-terminal-propeptide of type I collagen [PINP]) and bone resorption (type I collagen cross-linked C-telopeptide degradation fragments [CTx]) were measured at baseline, 3 months, 6 months and 18 months. A mixed-model of repeated measures analysed changes from baseline and between-group differences. Spearman correlations assessed the relationship between changes from baseline of bone markers with FEA variables. RESULTS: PINP and CTx levels increased in the teriparatide group and decreased in the risedronate group. FEA-derived parameters increased in both groups, but were significantly higher at 18 months in the teriparatide group. Significant positive correlations were found between changes from baseline of PINP at 3, 6 and 18 months with changes in FE strength in the teriparatide-treated group, but not in the risedronate group. CONCLUSIONS: Positive correlations between changes in a biochemical marker of bone formation and improvement of biomechanical properties support the use of PINP as a surrogate marker of bone strength in teriparatide-treated GIO patients.


Subject(s)
Bone Density Conservation Agents/therapeutic use , Glucocorticoids/adverse effects , Osteogenesis/drug effects , Osteoporosis/drug therapy , Teriparatide/therapeutic use , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Biomechanical Phenomena/drug effects , Biomechanical Phenomena/physiology , Bone Density/drug effects , Etidronic Acid/analogs & derivatives , Etidronic Acid/therapeutic use , Femur Neck/physiopathology , Finite Element Analysis , Humans , Lumbar Vertebrae/physiopathology , Male , Middle Aged , Osteogenesis/physiology , Osteoporosis/chemically induced , Osteoporosis/physiopathology , Peptide Fragments/blood , Procollagen/blood , Risedronic Acid , Treatment Outcome
14.
Med Phys ; 39(6Part28): 3970, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28519649

ABSTRACT

PURPOSE: To apply scanned ion radiotherapy to patients with moving tumors, motion mitigation approaches are needed. The purpose of the current study was to determine whether 4D optimized ion beam tracking therapy could reduce dose to critical structures near a moving target while maintaining target dose coverage. METHODS: A conjugate gradient minimization algorithm was developed to incorporate 4D organ motion data in the optimization of scanned ion pencil beam fluences. Treatment plans for 3D and 4D optimized carbon beam tracking were prepared using an in- house code for a sphere target volume moving in water with a proximal avoidance volume. For 1 lung cancer patient, 3D and 4D optimized carbon beam tracking treatment plans were designed to provide uniform dose coverage to a clinical target volume and minimal dose to the heart. For both the water phantom and patient case, 4D dose distributions were calculated. Differences between 3D and 4D optimized beam tracking were analyzed using dose colorplanes, dose-volume histograms, and dose-volume statistics. RESULTS: For the sphere target, 3D optimized beam tracking achieved target dose coverage of (100.0 ± 0.3)% and a mean and maximum avoidance volume dose of 26.1% and 89.4%, respectively. 4D optimized beam tracking achieved target dose coverage of (99.9 ± 0.4)% and a mean and maximum avoidance volume dose of 7.7% and 42.2%, respectively. For the lung patient, 3D optimized beam tracking achieved target dose coverage of (101.0 ± 5.9)% and a mean and maximum heart dose of 7.7%and 103.4%, respectively. 4D optimized beam tracking achieved target dose coverage of (100.0 ± 0.1)% and a mean and maximum heart dose of 8.7% and 100.3%, respectively. CONCLUSIONS: 4D optimized ion beam tracking therapy may be used to reduce the maximum dose to critical structures near a moving target, compared to 3D optimized ion beam tracking therapy. Work supported by the Rosalie B. Hite Fellowship, The University of Texas M. D. Anderson Cancer Center, Houston, Texas.

15.
Calcif Tissue Int ; 87(2): 130-6, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20571786

ABSTRACT

The treatment of osteoporotic patients with teriparatide is associated with a significant increase in bone formation and gain of bone mass. The purpose of this post hoc analysis was to determine if the cross-sectional area (CSA) of the spinal canal and the vertebral body is affected by teriparatide treatment. Narrowing of the spinal canal might represent a safety problem, while widening of the vertebral CSA might improve mechanical stability. High-resolution computed tomography (HRCT) scans of vertebra T12 were obtained at baseline and after 6, 12, and 24 months of teriparatide treatment (20 microg/day) from 44 postmenopausal women with established osteoporosis participating in the prospective, randomized EUROFORS study. The CSA of the spinal canal did not decrease but increased marginally by 0.9% (2.6 mm(2)) over 24 months (P < 0.001), with a range from -0.5% (-2 mm(2)) to 3.1% (+8 mm(2)). Even when analyzing the spinal CSA on a slice-by-slice basis, no clinically relevant narrowing of the spinal canal was observed. For vertebral bodies, the CSA increased by 0.7% (5.7 mm(2)) over 24 months (P < 0.001), with a range from -0.4% (-3 mm(2)) to 1.6% (+14 mm(2)). Our data do not provide evidence for safety concerns regarding spinal canal narrowing. On the other hand, the increases observed for vertebral CSA apparently also only minimally contribute to the mechanical strengthening of the vertebral body under teriparatide treatment.


Subject(s)
Bone Density Conservation Agents/therapeutic use , Osteoporosis/pathology , Spinal Canal/drug effects , Spine/drug effects , Teriparatide/therapeutic use , Aged , Bone Diseases, Developmental , Craniofacial Abnormalities , Female , Growth Disorders , Humans , Middle Aged , Osteoporosis/complications , Osteoporosis/diagnostic imaging , Osteoporosis/drug therapy , Postmenopause , Prospective Studies , Spinal Canal/diagnostic imaging , Spinal Canal/pathology , Spine/diagnostic imaging , Spine/pathology , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/drug effects , Thoracic Vertebrae/pathology , Tomography, X-Ray Computed
16.
Eur J Clin Pharmacol ; 65(4): 385-92, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19104789

ABSTRACT

PURPOSE: Statins have pleiotropic effects, including endothelial nitric oxide synthase (eNOS) upregulation and increased nitric oxide formation, which can be modulated by a genetic polymorphism in the promoter region of the eNOS gene (T-786C). Here, we report our investigation of whether this polymorphism modulates the effects of atorvastatin on the fluidity of erythrocyte membranes. METHODS: We genotyped 200 healthy subjects (males, 18-60 years of age) and then randomly selected 15 of these with the TT genotype and 15 with the CC genotype to receive placebo or atorvastatin (10 mg/day oral administration) for 14 days. Cell membrane fluidity was evaluated by electron paramagnetic resonance (EPR) and spin-labeling method. The EPR spectra were registered on a VARIAN-E4 spectrometer. Thiobarbituric acid-reactive species (TBA-RS) and plasma membrane cholesterol were determined in the erythrocytes. RESULTS: Atorvastatin reduced membrane fluidity in CC subjects (P < 0.05) but not in those with the TT genotype (P > 0.05). While no significant differences were found in plasma membrane cholesterol concentrations, higher TBA-RS concentrations were found in the CC subjects than in the TT subjects (P < 0.05). CONCLUSIONS: These findings suggest that a short treatment with atorvastatin is disadvantageous to subjects with the CC genotype for the T-786C polymorphism compared to those with TT genotype, at least in terms of the hemorheological properties of erythrocytes.


Subject(s)
Erythrocyte Membrane/drug effects , Heptanoic Acids/pharmacology , Hydroxymethylglutaryl-CoA Reductase Inhibitors/pharmacology , Membrane Fluidity , Nitric Oxide Synthase Type III/genetics , Polymorphism, Genetic , Pyrroles/pharmacology , Adult , Atorvastatin , Cholesterol/metabolism , Cysteine , Electron Spin Resonance Spectroscopy , Erythrocyte Membrane/genetics , Erythrocyte Membrane/metabolism , Genotype , Hemorheology , Humans , Male , Membrane Fluidity/drug effects , Membrane Fluidity/genetics , Middle Aged , Thiobarbiturates/metabolism , Threonine , Young Adult
17.
Photochem Photobiol ; 84(3): 627-31, 2008.
Article in English | MEDLINE | ID: mdl-18282181

ABSTRACT

We report an experimental and theoretical study of magnetic properties of synthetic eumelanin. The magnetization curves are determined by using both a vibrating sample magnetometer and a superconducting quantum interferometer device in an extended range of magnetic fields ranging from -10 kOe to 10 kOe at different temperatures. We find that the eumelanin magnetization can be qualitatively explained in terms of a simple model of dipolar spheres with an intrinsic magnetic moment. The latter one is experimentally measured by using X-band electron paramagnetic resonance. Our findings indicate that synthetic melanins are superparamagnetic.


Subject(s)
Magnetics , Melanins/chemistry , Computer Simulation , Electron Spin Resonance Spectroscopy , Melanins/chemical synthesis , Monte Carlo Method , Temperature
18.
Braz. j. med. biol. res ; 40(11): 1529-1536, Nov. 2007. graf, tab
Article in English | LILACS | ID: lil-464304

ABSTRACT

An analysis of scientific bibliographic productivity using the Hirsch h-index, information from the Institute of Scientific Information database and the Curriculum Lattes (CNPq, Brazil) was performed at the Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP-USP) that has four departments in natural, biological and social sciences. Bibliometric evaluations of undergraduate programs showed a better performance of the departments of Chemistry (P < 0.001) and Biology (P < 0.001) when compared to the departments of Physics and Mathematics and Psychology and Education. We also analyzed the scientific output of the six graduate programs of FFCLRP: Psychology, Psychobiology, Chemistry, Physics Applied to Medicine and Biology, Comparative Biology, and Entomology. The graduate program in Psychology presented a lower h-index (P < 0.001) and had fewer papers indexed by the ISI web of science (P < 0.001) when compared to the other graduate programs. The poorer performance of the Psychology program may be associated with the limited coverage by the Thompson Institute of Scientific Information database.


Subject(s)
Humans , Bibliometrics , Education, Graduate , Research Personnel/statistics & numerical data , Research/statistics & numerical data , Brazil , Databases, Bibliographic , Efficiency , Universities/statistics & numerical data
19.
Braz J Med Biol Res ; 40(11): 1529-36, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17934649

ABSTRACT

An analysis of scientific bibliographic productivity using the Hirsch h-index, information from the Institute of Scientific Information database and the Curriculum Lattes (CNPq, Brazil) was performed at the Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP-USP) that has four departments in natural, biological and social sciences. Bibliometric evaluations of undergraduate programs showed a better performance of the departments of Chemistry (P < 0.001) and Biology (P < 0.001) when compared to the departments of Physics and Mathematics and Psychology and Education. We also analyzed the scientific output of the six graduate programs of FFCLRP: Psychology, Psychobiology, Chemistry, Physics Applied to Medicine and Biology, Comparative Biology, and Entomology. The graduate program in Psychology presented a lower h-index (P < 0.001) and had fewer papers indexed by the ISI web of science (P < 0.001) when compared to the other graduate programs. The poorer performance of the Psychology program may be associated with the limited coverage by the Thompson Institute of Scientific Information database.


Subject(s)
Bibliometrics , Education, Graduate , Research Personnel/statistics & numerical data , Research/statistics & numerical data , Brazil , Databases, Bibliographic , Efficiency , Humans , Universities/statistics & numerical data
20.
Eur Phys J E Soft Matter ; 18(1): 21-8, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16172804

ABSTRACT

We have used electrically detected magnetic resonance (EDMR) to study a series of multilayer organic devices based on aluminum (III) 8-hydroxyquinoline (Alq3). These devices were designed to identify the microscopic origin of different spin-dependent processes, i.e. hopping and exciton formation. The EDMR signal in organic light-emitting diodes (OLEDs) based on Alq3 is only observed when the device is electroluminescent and is assigned to spin-dependent exciton formation. It can be decomposed in at least two Gaussians: one with peak-to-peak line (deltaH(PP)) of 1.6 mT and another with deltaH(PP) of 2.0 to 3.4 mT, depending on bias and temperature. The g-factors of the two components are barely distinguishable and close to 2.003. The broad line is attributed to the resonance in Alq3 anions, while the other line is attributed to cationic states. These attributions are supported by line shape and its electrical-field dependence of unipolar Alq3-based diodes, where hopping process related to dication and dianion formation is observed. In these unipolar devices, it is shown that the signal coming from spin-dependent hopping occurs close to organic semiconductor/metal interfaces. The sign of the magnetic-resonance-induced conductivity change is dominated by charge injection rather than charge mobility. Our results indicate that the probability of singlet exciton formation in our OLEDs is smaller than 25%.

SELECTION OF CITATIONS
SEARCH DETAIL
...