Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-16962397

ABSTRACT

A simple detection system with a high-performance liquid chromatography (HPLC) with positive ionisation-tandem mass spectrometry (ESI-MS/MS) for determining diphemanil methylsulphate (DMS) levels in human plasma using 4-diphemanylmethylene,1-methylpiperidine as an internal standard (I.S.), is proposed. The acquisition was performed with the multiple reactional monitoring (MRM) mode, by monitoring the transitions: m/z 278>262 for DMS and m/z 263>247 for the I.S. The method involved a simple single-step deproteinisation with acetonitrile. The analyte was chromatographed on a Zorbax C18 reversed-phase chromatographic column by isocratic elution with 10(-3)M ammonium acetate and 10(-3)M hexafluorobutyric acid, adjusted to pH 7.0 with ammoniac/acetonitrile (40/60, v/v). The results were linear over the studied range (0.5-50.0 ng mL(-1)) and the total analysis time for each run was 10 min. The mean extraction apparent recoveries expressed at the 95% intervals of confidence were 94-104% for DMS and 92-106% for the I.S. The intra- and inter-assay precisions were 4.6-8.4% and 2.9-10.6%, respectively. The limit of quantification was 0.15 ng mL(-1). The devised assay was successfully applied to the residual concentrations monitoring in infant.


Subject(s)
Chromatography, High Pressure Liquid/methods , Piperidines/blood , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Humans , Infant , Piperidines/therapeutic use , Reproducibility of Results
2.
Article in English | MEDLINE | ID: mdl-15135099

ABSTRACT

In order to quantify a small amount of a drug, 3,4-diaminopyridine (3,4-DAP), in animal plasma samples, an analytical method was developed. It involved an extraction of 3,4-DAP and phenylephrine, used as internal standard (IS), from plasma with solid-phase extraction (SPE) on C18 cartridges. This analytical method is a hyphenated technique based on high-performance liquid chromatography with electrochemical detection (HPLC-EC) whose purpose is to obtain first a sensitive method and second a satisfying separation between 3,4-DAP and phenylephrine. The analytical method is accurate, specific, and linear between 10 and 500 g of 3,4-DAP per litre. The recovery of 3,4-DAP is estimated at 70.8% with a 95% confidence interval of (66.0 -75.6%). Intermediate precision was evaluated on three quality control samples; the intra-day precision was estimated at 13.5, 9.1, 7.8% and the inter-day precision at 17.9, 8.4, 9.3%. The limit of quantification of the method was evaluated at 10 g l-1. First toxicokinetic parameters determined on dogs plasma samples after one 3,4-DAP oral administration of 1 mg kg-1 were: Cmax=395.7 microg l-1; Tmax =15 min; t1/2=113.6 min; Clearance/F=16.8 ml kg-1 min-1 and Vd/F=2.7 l kg -1.


Subject(s)
4-Aminopyridine/analogs & derivatives , 4-Aminopyridine/blood , Chromatography, High Pressure Liquid/methods , Electrochemistry/methods , Amifampridine , Animals , Dogs , Female , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...