Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Med Qual ; 34(5): 488-493, 2019.
Article in English | MEDLINE | ID: mdl-31479293

ABSTRACT

Advances in neonatology led to survival of micro-preemies, who need central lines. Central line-associated bloodstream infection (CLABSI) causes prolonged hospitalization, morbidities, and mortality. Health care team education decreases CLABSIs. The objective was to decrease CLABSIs using evidence-based measures. The retrospective review compared CLABSI incidence during and after changes in catheter care. In April 2011, intravenous (IV) tubing changed from Interlink to Clearlink; IV tubing changing interval increased from 24 to 72 hours. CLABSIs increased. The following measures were implemented: July 2011, reeducation of neonatal intensive care staff on Clearlink; August 2011, IV tubing changing interval returned to 24 hours; September 2011, changed from Clearlink back to Interlink; November 2011, review of entire IV process and in-service on hand hygiene; December 2011, competencies on IV access for all nurses. CLABSIs were compared during and after interventions. Means were compared using the t test and ratios using the χ2 test; P <.05. CLABSIs decreased from 4.4/1000 to 0/1000 catheter-days; P < .05. Evidence-based interventions reduced CLABSIs.

2.
Am J Med Qual ; 31(2): 133-8, 2016.
Article in English | MEDLINE | ID: mdl-25372275

ABSTRACT

Advances in neonatology led to survival of micro-preemies, who need central lines. Central line-associated bloodstream infection (CLABSI) causes prolonged hospitalization, morbidities, and mortality. Health care team education decreases CLABSIs. The objective was to decrease CLABSIs using evidence-based measures. The retrospective review compared CLABSI incidence during and after changes in catheter care. In April 2011, intravenous (IV) tubing changed from Interlink to Clearlink; IV tubing changing interval increased from 24 to 72 hours. CLABSIs increased. The following measures were implemented: July 2011, reeducation of neonatal intensive care staff on Clearlink; August 2011, IV tubing changing interval returned to 24 hours; September 2011, changed from Clearlink back to Interlink; November 2011, review of entire IV process and in-service on hand hygiene; December 2011, competencies on IV access for all nurses. CLABSIs were compared during and after interventions. Means were compared using the t test and ratios using the χ(2) test; P <.05. CLABSIs decreased from 4.4/1000 to 0/1000 catheter-days; P < .05. Evidence-based interventions reduced CLABSIs.


Subject(s)
Catheter-Related Infections/prevention & control , Infection Control/organization & administration , Intensive Care Units, Neonatal/organization & administration , Birth Weight , Evidence-Based Medicine , Female , Gestational Age , Humans , Infant, Newborn , Infection Control/instrumentation , Inservice Training , Male , Quality Improvement/organization & administration , Retrospective Studies , Time Factors
3.
Am J Infect Control ; 36(6): 392-8, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18675144

ABSTRACT

BACKGROUND: As pertussis disease becomes more common, health care-associated outbreaks have been reported with increasing frequency. Often, these clusters are costly and labor intensive to investigate and contain. It is clear that health care workers are among the adults who transmit pertussis to susceptible infants. Recent focus on patient safety, together with a concern for protecting employees in the workplace and those they expose elsewhere, has spurred interest in optimizing measures to prevent infection and disease transmission. Shortly after a tetanus toxoid, reduced diphtheria toxoid and acellular pertussis vaccine adsorbed booster was licensed and became available, we designed, launched, and analyzed a campaign to immunize the employees of our institution against pertussis. METHODS: To optimize acceptance of a tetanus toxoid, reduced diphtheria toxoid and acellular pertussis vaccine adsorbed booster by employees, we adopted a program consisting of a 3-phase publicity and educational model and a 3-phase vaccine delivery approach. RESULTS: Despite extraordinary resources dedicated to this program, and our institution's better than average annual uptake of influenza vaccine, less than one third of our eligible employees were immunized. A significant number of employees declined to be vaccinated for inappropriate reasons. CONCLUSION: A campaign of this kind is quite labor intensive and expensive, yet limited overall vaccine uptake was achieved. A federal mandate to require pertussis immunization of all health care workers appears to be a more effective way to protect our patients, employees, families, and society.


Subject(s)
Cross Infection/prevention & control , Health Personnel , Immunization Programs/economics , Pertussis Vaccine/administration & dosage , Whooping Cough/prevention & control , Cross Infection/epidemiology , Diphtheria Toxoid/administration & dosage , Hospitals, Teaching , Humans , Tetanus Toxoid/administration & dosage , Treatment Outcome , Whooping Cough/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...