Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 88
Filter
1.
Eur J Heart Fail ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726573

ABSTRACT

AIM: This analysis aimed to compare the clinical outcomes associated with heart failure (HF) readmissions and to identify associations with HF hospitalizations (HFH) in patients treated with the MitraClip™ NTR/XTR System in the EXPAND study. METHODS AND RESULTS: The global, real-world EXPAND study enrolled 1041 patients with primary or secondary mitral regurgitation (MR) treated with the MitraClip NTR/XTR System. Echocardiograms were analysed by an independent echocardiographic core laboratory. The study population was stratified into HFH and No-HFH groups based on the occurrence of HFH 1 year post-index procedure. Clinical outcomes including MR severity, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ) score, and all-cause mortality were compared (HFH: n = 181; No-HFH: n = 860). Both groups achieved consistent 1-year MR reduction to ≤1+ (HFH vs. No-HFH: 87.3% vs. 89.5%, p = 0.6) and significant 1-year improvement in KCCQ scores (+16.5 vs. +22.3, p = 0.09) and NYHA functional class. However, more patients in the No-HFH group had 1-year NYHA class ≤II (HFH vs. No-HFH: 67.9% vs. 81.9%, p < 0.01). All-cause mortality at 1 year was 36.8% in the HFH group versus 10.4% in the No-HFH group (p < 0.001). The HFH rate decreased by 63% at 1 year post-M-TEER versus 1 year pre-treatment (relative risk 0.4, p < 0.001). Independent HFH associations were MR ≥2+ at discharge, HFH 1 year prior to treatment, baseline NYHA class ≥III, baseline tricuspid regurgitation ≥2+, and baseline left ventricular ejection fraction ≤40%. CONCLUSIONS: This study reports the impact of HFH on clinical outcomes post-treatment in the EXPAND study. Results demonstrate that the occurrence of HFH was associated with worse 1-year survival, and treatment with the MitraClip system substantially reduced HFH and improved patient symptoms and quality of life.

2.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38629416

ABSTRACT

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Aortic Valve/surgery , Heart Ventricles , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left , Multicenter Studies as Topic , Clinical Studies as Topic
4.
Am J Cardiol ; 211: 219-227, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-37944779

ABSTRACT

Atrial functional mitral regurgitation (aFMR) has a peculiar pathophysiology that may have distinctive outcomes. We investigated the impact of transcatheter edge-to-edge repair in aFMR compared with other FMR etiologies. The GIOTTO (GIse registry Of Transcatheter treatment of MR) is a multicenter, prospective study enrolling patients with symptomatic MR treated with MitraClip up to 2020. We categorized patients with FMR as aFMR, ischemic FMR (iFMR), and nonischemic ventricular FMR (niFMR). The clinical end points were defined according to the Mitral Valve Academic Research Consortium. Of 1,153 patients, 6% had aFMR, 47% iFMR, and 47% niFMR. Patients with aFMR were older, mostly women, and had a higher atrial fibrillation rate. They had better left ventricular ejection fraction and smaller left ventricular volumes, with no difference in mitral effective regurgitant orifice area. The acute device and procedural success rates were similar among the groups. At the longest available follow-up (median 478 days, interquartile range 91 to 741 days), the rate of MR ≥2+ was similar among the groups. Patients with aFMR had a lower rate of cardiovascular death and heart failure than patients with iFMR (hazard ratio [HR] 0.43, p = 0.02) and niFMR (HR 0.45, p = 0.03). The aFMR etiology remained independently associated with the composite outcome, together with postprocedural MR ≤1+ (HR 0.63, p <0.01) and peripheral arteriopathy (HR 1.82, p = 0.003). The results of this GIOTTO subanalysis suggested that aFMR is less prevalent and associated with better outcomes compared with other causes of FMR treated by transcatheter edge-to-edge repair. Postprocedural MR >1+, peripheral vasculopathy, non-aFMR were independent predictors of worse outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Female , Male , Mitral Valve/surgery , Stroke Volume , Prospective Studies , Ventricular Function, Left , Registries , Treatment Outcome , Heart Valve Prosthesis Implantation/methods
5.
EuroIntervention ; 19(11): e926-e936, 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-37946539

ABSTRACT

BACKGROUND: In the context of primary mitral regurgitation (PMR), the selection of patients for transcatheter edge-to-edge repair (TEER) does not include a systematic assessment of PMR-associated cardiac remodelling. AIMS: We aimed to investigate the epidemiology and prognostic significance of different phenotypes of extra-mitral valve (MV) cardiac involvement in a large series of patients with PMR referred for TEER. METHODS: The study included 654 patients from the multicentre Italian GIOTTO registry, stratified into groups according to extra-mitral valve (MV) cardiac involvement. The primary endpoint was all-cause death at 2-year follow-up. RESULTS: Patients with no cardiac involvement (NI; n=58), left heart involvement (LHI; n=343) and right heart involvement (RHI; n=253) were analysed. Acute technical success was achieved in 98% of patients. Kaplan-Meier curve analysis revealed significantly worse survival in patients with LHI and RHI (p=0.041). On multivariate Cox regression analysis, extra-MV cardiac involvement, haemoglobin level and technical success were independent predictors of the primary endpoint occurrence. CONCLUSIONS: Grading cardiac involvement may help refine risk stratification, since at least 1 group of extra-MV cardiac involvement represents in itself a negative predictor of midterm outcome.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Kaplan-Meier Estimate , Multivariate Analysis , Patients , Treatment Outcome , Cardiac Catheterization
6.
J Clin Med ; 12(20)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37892796

ABSTRACT

This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.

7.
J Clin Med ; 12(14)2023 Jul 18.
Article in English | MEDLINE | ID: mdl-37510857

ABSTRACT

BACKGROUND: Concomitant mitral transcatheter edge-to-edge repair (M-TEER) and left atrial appendage closure (LAAC) showed to be a feasible approach to optimize the treatment of patients eligible for both procedures, but mid-term outcomes are unclear. METHODS: We retrospectively analyzed consecutive patients undergoing M-TEER and enrolled in the local prospective Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation (GRASP) registry. We compared patients undergoing isolated M-TEER (n = 58, 58.5%) with those undergoing concomitant M-TEER and LAAC (n = 41, 41.5%) from January 2018 to December 2022. The primary endpoint was a composite of all-cause death, stroke or systemic embolism, hospitalization for heart failure, and bleeding at 1 year. The co-primary endpoint was procedural success. RESULTS: The primary endpoint was similar between patients undergoing concomitant M-TEER+LAAC or isolated M-TEER (Kaplan Meier (KM) estimates 36.6% vs. 44.8%; plog-rank = 0.75). Procedural success was also similar (92.7% vs. 94.8%; p = 0.69). At 1- year, minor bleeds were lower in patients undergoing concomitant M-TEER and LAAC (KM estimates 0.0% vs. 18.9%; plog-rank < 0.01). CONCLUSION: In patients with concomitant MR and AF and eligible for M-TEER and LAAC treatment, a combined approach of M-TEER and LAAC was as safe as an M-TEER-alone strategy and associated with lower minor bleeding at 1 year.

8.
Front Cardiovasc Med ; 10: 1172005, 2023.
Article in English | MEDLINE | ID: mdl-37383696

ABSTRACT

Background: Percutaneous left atrial appendage occlusion (LAAO) presents many technical complex features, and it is often performed under the intraprocedural surveillance of a product specialist (PS). Our aim is to assess whether LAAO is equally safe and effective when performed in high-volume centers without PS support. Methods: Intraprocedural results and long-term outcome were retrospectively assessed in 247 patients who underwent LAAO without intraprocedural PS monitoring between January 2013 and January 2022 at three different hospitals. This cohort was then matched to a population who underwent LAAO with PS surveillance. The primary end point was all-cause mortality at 1 year. The secondary end point was a composite of cardiovascular mortality plus nonfatal ischemic stroke occurrence at 1 year. Results: Of the 247 study patients, procedural success was achieved in 243 patients (98.4%), with only 1 (0.4%) intraprocedural death. After matching, we did not identify any significant difference between the two groups in terms of procedural time (70 ± 19 min vs. 81 ± 30 min, p = 0.106), procedural success (98.4% vs. 96.7%, p = 0.242), and procedure-related ischemic stroke (0.8% vs. 1.2%, p = 0.653). Compared to the matched cohort, a significant higher dosage of contrast was used during procedures without specialist supervision (98 ± 19 vs. 43 ± 21, p < 0.001), but this was not associated with a higher postprocedural acute kidney injury occurrence (0.8% vs. 0.4%, p = 0.56). At 1 year, the primary and the secondary endpoints occurred in 21 (9%) and 11 (4%) of our cohort, respectively. Kaplan-Meier curves showed no significant difference in both primary (p = 0.85) and secondary (p = 0.74) endpoint occurrence according to intraprocedural PS monitoring. Conclusions: Our results show that LAAO, despite the absence of intraprocedural PS monitoring, remains a long-term safe and effective procedure, when performed in high-volume centers.

9.
Am J Cardiol ; 200: 178-187, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37331223

ABSTRACT

Despite the growing experience with MitraClip in the broad spectrum of mitral regurgitation (MR), limited data are available regarding the independent prognostic role on survival of different mitral regurgitation etiology subtypes. We sought to evaluate the impact of flail leaflet etiology in a large series of patients with primary MR (PMR) who underwent MitraClip treatment. The study included 588 patients with significant PMR from the multicenter GIOTTO (Italian Society of Interventional Cardiology [GIse] registry Of Transcatheter treatment of mitral valve regurgitaTiOn), stratified into 2 groups according to MR etiology: flail+ (n = 300) and flail- (n = 288). The primary end point was a composite of cardiac death and first rehospitalization for heart failure (HF). To account for the baseline differences, patients were propensity score-matched 1:1. Flail leaflet etiology was present in about a half of the patients. Acute technical success was achieved in 98% of the overall cohort, with no significant differences between the study groups (p = 0.789). At the 2-year Kaplan-Meier analysis, the primary end point occurred in 13% of flail+ patients compared with 23% in flail- (p = 0.009). The flail+ group presented lower rates of both cardiac death and rehospitalization for HF, whereas a similar overall death rate was observed between the groups. A multivariate Cox regression analysis identified flail leaflet etiology as an independent predictor of favorable outcome in terms of the primary end point (hazard ratio 0.141, 95% confidence interval 0.049 to 0.401, p <0.001). After propensity score matching, flail+ patients had confirmed lower rates of cardiac mortality and rehospitalization for HF but similar rates of overall death. In conclusion, flail leaflet-related etiology was common in patients with PMR who underwent MitraClip treatment and was an independent predictor of midterm favorable clinical outcomes.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Prognosis , Treatment Outcome , Proportional Hazards Models , Heart Failure/complications , Death , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
10.
Int J Cardiol ; 390: 131139, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37355239

ABSTRACT

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Subject(s)
Heart Failure , Heart Transplantation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Stroke Volume , Ventricular Function, Left , Time Factors , Heart Transplantation/adverse effects , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Failure/diagnosis , Heart Failure/surgery , Registries , Heart Valve Prosthesis Implantation/methods
11.
Catheter Cardiovasc Interv ; 102(2): 310-317, 2023 08.
Article in English | MEDLINE | ID: mdl-37232290

ABSTRACT

BACKGROUND: The relationship between high postprocedural mean gradient (ppMG) and clinical events following mitral valve transcatheter edge-to-edge repair (MV-TEER) in patients with degenerative mitral regurgitation (DMR) is still debated. AIM: The purpose of this study was to evaluate the effect of elevated ppMG after MV-TEER on clinical events in patients with DMR at 1-year follow-up. METHODS: The study included 371 patients with DMR treated with MV-TEER enrolled in the "Multi-center Italian Society of Interventional Cardiology (GISE) registry of trans-catheter treatment of mitral valve regurgitation" (GIOTTO) registry. Patients were stratified in tertiles according to ppMG. Primary endpoint was a composite of all-cause death and hospitalization due to heart failure at 1-year follow-up. RESULTS: Patients were stratified as follows: 187 with a ppMG ≤ 3 mmHg, 77 with a ppMG > 3/=4 mmHg, and 107 with a ppMG > 4 mmHg. Clinical follow-up was available in all subjects. At multivariate analysis, neither a ppMG > 4 mmHg nor a ppMG ≥ 5 mmHg were independently associated with the outcome. Notably, the risk of elevated residual MR (rMR > 2+) was significantly higher in patients belonging to the highest tertile of ppMG (p = 0.009). The association of ppMG > 4 mmHg and rMR ≥ 2+ was strongly and independently associated with adverse events (hazard ratio: 1.98; 95% confidence interval: [1.10-3.58]). CONCLUSIONS: In a real-world cohort of patients suffering DMR and treated with MV-TEER, isolated ppMG was not associated with the outcome at 1-year follow-up. A high proportion of patients showed both elevated ppMG and rMR and their combination appeared to be a strong predictor of adverse events.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
12.
Front Cardiovasc Med ; 10: 1115811, 2023.
Article in English | MEDLINE | ID: mdl-37180775

ABSTRACT

Introduction: The Watchman FLX is a novel device for transcatheter left atrial appendage occlusion (LAAO) specifically designed to improve procedural performance in more complex anatomies with a better safety profile. Recently, small prospective non-randomized studies have shown good procedural success and safety compared with previous experiences. Results from large multicenter registries are needed to confirm the safety and efficacy of the Watchman FLX device in a real-world setting. Methods: Italian FLX registry is a retrospective, non-randomized, multicentric study across 25 investigational centers in Italy including consecutive patients undergoing LAAO with the Watchman FLX between March 2019 and September 2021 (N = 772). The primary efficacy outcome was the technical success of the LAAO procedure (peri-device flow ≤ 5 mm) as assessed by intra-procedural imaging. The peri-procedural safety outcome was defined as the occurrence of one of the following events within 7 days after the procedure or by hospital discharge: death, stroke, transient ischemic attack, major extracranial bleeding (BARC type 3 or 5), pericardial effusion with tamponade or device embolization. Results: A total of 772 patients were enrolled. The mean age was 76 ± 8 with a mean CHA2DS2-VASc score of 4.1 ± 1.4 and a mean HAS-BLED score of 3.7 ± 1.1. Technical success was achieved in 772 (100%) patients with the first device implanted in 760 (98.4%) patients. A peri-procedural safety outcome event occurred in 21 patients (2.7%) with major extracranial bleeding being the most common (1.7%). No device embolization occurred. At discharge 459 patients (59.4%) were treated with dual antiplatelet therapy (DAPT). Conclusions: The Italian FLX registry represents the largest multicenter retrospective real-world study reporting periprocedural outcome of LAAO with the Watchman FLX device, resulting in a procedural success rate of 100% and a low incidence of peri-procedural major adverse events (2.7%).

13.
JACC Cardiovasc Interv ; 16(5): 589-602, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36922046

ABSTRACT

BACKGROUND: The third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system was introduced to assist in leaflet grasping with the longer clip arms of MitraClip XTR and to improve ease of use with the modified delivery catheter. OBJECTIVES: The EXPAND study evaluated contemporary real-world outcomes in subjects with mitral regurgitation (MR) treated with the third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system. METHODS: EXPAND is a prospective, multicenter, international, single-arm study that enrolled patients with primary MR and secondary MR at 57 centers. Follow-up was conducted through 12 months. Echocardiograms were analyzed by an echocardiographic core laboratories. Study outcomes included: MR severity, functional capacity measured by New York Heart Association functional class, quality of life measured by Kansas City Cardiomyopathy Questionnaire, heart failure hospitalizations, all-cause mortality. RESULTS: 1,041 patients were enrolled from April 2018 through March 2019, of which 50.5% had primary or mixed etiology. Implant success was 98.9%; 1.5 ± 0.6 clips were implanted per subject. Significant MR reduction from baseline (≥MR 3+: 56.0%) to 30 days (≤MR 1+:88.8%) was maintained through 1 year (MR ≤1+: 89.2%). A total of 84.5% and 93.0% of subjects in primary MR and secondary MR, respectively, had ≤1+ MR at 1 year. Significant improvements were observed in clinical outcomes (New York Heart Association functional class I/II in 80.3%, +21.6 improvement in Kansas City Cardiomyopathy Questionnaire score) at 1 year. All-cause mortality and heart failure hospitalizations at 1 year were 14.9% and 18.9%, respectively, which was significantly lower than previous studies. CONCLUSIONS: The study demonstrates treatment with the third-generation system resulted in substantial reduction of MR in a contemporary real-world practice, compared with the results of earlier EVEREST and COAPT trials.(The MitraClip® EXPAND Study of the Next Generation of MitraClip® Devices [EXPAND]; NCT03502811).


Subject(s)
Cardiomyopathies , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Quality of Life , Prospective Studies , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Heart Failure/diagnostic imaging , Heart Failure/therapy , Heart Failure/complications , Cardiac Catheterization , Cardiomyopathies/complications
14.
EuroIntervention ; 18(17): 1408-1417, 2023 Apr 24.
Article in English | MEDLINE | ID: mdl-36809256

ABSTRACT

BACKGROUND: A risk score was recently derived from the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) Trial. However, external validation of this score is still lacking. AIMS: We aimed to validate the COAPT risk score in a large multicentre population undergoing mitral transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR). METHODS: The Italian Society of Interventional Cardiology (GIse) Registry of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO) population was stratified according to COAPT score quartiles. The performance of the COAPT score for 2-year all-cause death or heart failure (HF) hospitalisation was evaluated in the overall population and in patients with or without a COAPT-like profile. RESULTS: Among the 1,659 patients included in the GIOTTO registry, 934 had SMR and complete data for a COAPT risk score calculation. The incidence of 2-year all-cause death or HF hospitalisation progressively increased through the COAPT score quartiles in the overall population (26.4% vs 44.5% vs 49.4% vs 59.7%; log-rank p<0.001) and COAPT-like patients (24.7% vs 32.4% vs 52.3% vs. 53.4%; log-rank p=0.004), but not in those with a non-COAPT-like profile. The COAPT risk score had poor discrimination and good calibration in the overall population, moderate discrimination and good calibration in COAPT-like patients and very poor discrimination and poor calibration in non-COAPT-like patients. CONCLUSIONS: The COAPT risk score has a poor performance in the prognostic stratification of real-world patients undergoing M-TEER. However, after application to patients with a COAPT-like profile, moderate discrimination and good calibration were observed.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Risk Factors , Hospitalization , Treatment Outcome
15.
Eur J Heart Fail ; 25(3): 411-421, 2023 03.
Article in English | MEDLINE | ID: mdl-36597850

ABSTRACT

AIMS: Mitral valve transcatheter edge-to-edge repair is a guideline-recommended treatment option for patients with secondary mitral regurgitation (SMR). The purpose of this analysis was to report contemporary real-world outcomes in SMR patients treated with third-generation MitraClip systems. METHODS AND RESULTS: EXPAND is a prospective, multicentre, international, single-arm study with 1041 patients treated for mitral regurgitation (MR) with MitraClip NTR/XTR, with 30-day and 1-year follow-up. All echocardiograms were analysed by an independent echocardiographic core lab. Study outcomes included procedural outcomes, durability of MR reduction, and major adverse events including all-cause mortality and heart failure hospitalizations (HFH). A subgroup of 413 symptomatic patients (age 74.7 ± 10.1 years, 58% male) with severe SMR were included. MR reduction to MR ≤ 1+ and MR ≤ 2+ was achieved in 93.0% and 98.5% of patients, respectively, which was sustained at 1-year follow-up. All-cause mortality was 17.7% at 1-year- follow-up, and the combined endpoint of all-cause mortality or first HFH occurred in 34% of patients. This combined endpoint was significantly less frequently observed in MR ≤ 1+ patients (Kaplan-Maier estimates: 29.7% vs. 69.6% for MR ≤ 1+ vs. MR ≥ 2 +; p < 0.0001). New York Heart Association (NYHA) functional class improved significantly from baseline (NYHA ≤ II: 17%) to 1-year follow-up (NYHA ≤ II: 78%) (p < 0.0001). While MR reduction was comparable between NTR-only vs. XTR-only treated patients, less XTR clips were required for achieving MR reduction. CONCLUSIONS: Under real-world conditions, optimal sustained MR reduction to MR ≤ 1+ was achieved in a high percentage of patients with third-generation MitraClip, which translated into symptomatic improvement and low event rates. These results appear to be comparable with recent randomized clinical trials.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Treatment Outcome , Cardiac Catheterization
16.
ESC Heart Fail ; 10(2): 1122-1132, 2023 04.
Article in English | MEDLINE | ID: mdl-36599332

ABSTRACT

AIM: Patients with severe mitral regurgitation (MR) and acute heart failure (HF) have refractory symptoms without adequate response to medical therapy. The objective of this analysis was to assess the impact of the MitraClip device in acutely ill HF patients, characterized by NYHA Class IV at baseline, in a real-world, contemporary setting. METHODS AND RESULTS: EXPAND was a prospective, multicenter, international study enrolling patients with MR who consented to receive the MitraClip System at 57 sites globally. The study outcomes included acute procedural success (APS), quality of life, heart failure hospitalizations (HFH), and all-cause mortality. The study population comprised 1,041 patients, with 118 patients having baseline NYHA Class IV, and 922 having baseline NYHA Class I/II/III. NYHA Class IV patients had a significantly higher rate of baseline co-morbidities and secondary MR aetiology compared with NYHA Class I/II/III patients. APS was achieved in 92.4% of NYHA Class IV patients and significant improvement in MR grade to ≤Mild (1+) in 90.7% of subjects at 30 days and 92.9% at 1 year was observed. 1-year-mortality was higher in the NYHA Class IV subjects compared with the NYHA Class I/II/III subjects (29.2% vs. 17.7%, P < 0.01). Significant improvement in functional capacity assessed by NYHA Functional Class and Quality of Life assessed through KCCQ score was observed. At 1 year, 72.6% of NYHA Class IV subjects improved to NYHA Class I/II and ΔKCCQ was 31.2 (24.1, 38.3) compared with baseline. CONCLUSION: In the prospective, real-world EXPAND study, MitraClip in patients with severe MR and NYHA Class IV was found to be safe and effective in treating MR, and significantly improving QoL and long-term clinical outcomes.


Subject(s)
Heart Failure , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Prospective Studies , Heart Failure/complications , Heart Failure/surgery
17.
Am J Cardiol ; 186: 100-108, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36356428

ABSTRACT

Up to half of real-world patients with secondary mitral regurgitation who underwent transcatheter edge-to-edge repair (TEER) do not meet the highly selective COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) criteria. No randomized trials or standardized and validated tools exist to evaluate the risk: benefit ratio of TEER in this specific population. We sought to derive and externally validate a clinical risk score to predict the risk of death or heart failure (HF) hospitalization for COAPT-ineligible patients who underwent TEER (CITE score). The study population consisted of patients with secondary mitral regurgitation having at least 1 exclusion criterion of the COAPT trial. The derivation cohort included 489 patients from the GIOTTO (GIse registry of Transcatheter treatment of Mitral Valve regurgitaTiOn) registry. Cox proportional hazards regression was used to identify predictors of 2-year death/HF hospitalization and develop a numerical risk score. The predictive performance was assessed in the derivation cohort and validated in 268 patients from the MiZüBr (Milan-Zürich-Brescia) registry. The CITE score (hemodynamic instability, left ventricular impairment, New York Heart Association class III/IV, peripheral artery disease, atrial fibrillation, brain natriuretic peptide, and hemoglobin) showed a c-index for 2-year death or HF hospitalization of 0.70 (95% confidence interval [CI] 0.67 to 0.73) in the derivation cohort, and 0.68 (95% CI 0.64 to 0.73) in the validation cohort. A cutoff of <12 points was selected to identify patients at lower risk of adverse outcomes, hazard ratio of 0.35 (95% CI 0.26 to 0.46). In conclusion, the CITE score is a simple 7-item tool for the prediction of death or HF hospitalization at 2 years after TEER in COAPT-ineligible patients. The score may support clinical decision-making by identifying those patients who, even if excluded from clinical trials, can still benefit from TEER.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Natriuretic Peptide, Brain , Risk Factors , Treatment Outcome
18.
Am J Cardiol ; 182: 46-54, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36075753

ABSTRACT

Despite being highly effective in reducing residual mitral regurgitation and improving outcomes, mitral valve transcatheter edge-to-edge repair (MV-TEER) may be associated with high postprocedural residual mitral gradient (rMG). Conflicting results have been reported regarding the relation between rMG and adverse events. This study aimed to evaluate the predictors and the impact of elevated rMG after MV-TEER on clinical events in patients with functional mitral regurgitation (FMR) at 2 years follow-up. We selected a cohort of 864 patients with FMR who were treated with MV-TEER enrolled in the multicentre Italian Society of Interventional Cardiology (GISE) registry of transcatheter treatment of mitral valve regurgitation (GIOTTO). Patients were stratified into tertiles according to rMG. The primary clinical end point was a composite of all-cause death and hospitalization because of heart failure at 2-year follow-up. Overall, 269 patients (31.5%) with an rMG <3 mm Hg, 259 (30.3%) with an rMG ≥3/<4 mm Hg, and 326 (38.2%) with an rMG ≥4 mm Hg were considered. At multivariate logistic regression, ischemic FMR etiology, baseline MG, and the number of implanted clips were independent predictors of an rMG ≥4 mm Hg. Clinical follow-up was available in 570 patients (63.2%). Patients with an rMG ≥4 mm Hg experienced higher rates of the composite end point than patients of the other tertiles (51.1%, vs 42.3% vs 40.8% log-rank test: p = 0.033). In multivariate Cox's regression, both rMG ≥4 mm Hg (hazard ratio 1.54, 95% confidence interval 1.14 to 2.08) and residual mitral regurgitation ≥2+ (hazard ratio 1.36, 95% confidence interval 1.01 to 1.83) were independent predictors of adverse events at 2-year follow-up. In conclusion, we demonstrated that real-world patients who underwent MV-TEER who show an rMG ≥4 mm Hg are at higher risk of death or hospitalization because of heart failure during a 2-year follow-up. Further studies will be needed to confirm our results.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization/methods , Disease Progression , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve/surgery , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 100(3): 451-460, 2022 09.
Article in English | MEDLINE | ID: mdl-35644994

ABSTRACT

BACKGROUND: Mitral-valve transcatheter edge-to-edge repair (MV-TEER) is recommended in patients with severe functional mitral regurgitation (FMR) and in those with degenerative mitral regurgitation (DMR) not eligible to traditional surgery. Patients with a history of previous cardiac surgery are considered at high risk for surgical reintervention, but data are lacking regarding procedural and clinical outcomes. OBJECTIVE: aim of this study was to assess the efficacy and clinical results of MV-TEER in patients with previous cardiac surgery enrolled in the "multicentre Italian Society of Interventional Cardiology registry of transcatheter treatment of mitral valve regurgitation" (GIOTTO). METHODS: Patients with previous coronary artery bypass grafting (CABG), surgical aortic valve replacement (AVR), or mitral valve repair (MVR) were included. Those with multiple or combined previous cardiac surgeries were excluded. Clinical follow-up was performed at 30 days, 1 year, and 2 years. The primary endpoint was a composite of death or rehospitalization at 1- and 2-year follow-ups. RESULTS: A total of 330 patients enrolled in the GIOTTO registry were considered (CABG 77.9%, AVR 14.2%, and MVR 7.9%). Most patients showed FMR (66.9%), moderate reduction of left ventricular (LV) ejection fraction, and signs of LV dilation. Procedural and device successes were 94.8% and 97%. At 1 and 2 years, the composite endpoint occurred are 29.1% and 52.4%, respectively. The composite outcome rates were similar across the three subgroups of previous cardiac surgery (p = 0.928) and between the FMR and DMR subgroups (p = 0.850) at 2 years. In a multivariate analysis, residual mitral regurgitation (rMR) ≥2+ was the main predictor of adverse events at 1 year (hazard ratio: 1.54 [95% confidence interval, CI: 1.00-2.38]; p = 0.050). This association was confirmed at 2 years of Kaplan-Meier analysis (p = 0.001). CONCLUSIONS: MV-TEER is effective in these patients, regardless of the subtype of previous cardiac surgery and the MR etiology. An rMR ≥2+ is independently associated with adverse outcomes at 1-year follow-up.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization , Cardiac Surgical Procedures/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Treatment Outcome
20.
JACC Cardiovasc Interv ; 15(12): 1266-1274, 2022 06 27.
Article in English | MEDLINE | ID: mdl-35738747

ABSTRACT

BACKGROUND: Data on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference on these outcomes are limited. OBJECTIVES: The aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference. METHODS: In a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference. RESULTS: In total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032). CONCLUSIONS: Periprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...