Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Front Neural Circuits ; 10: 85, 2016.
Article in English | MEDLINE | ID: mdl-27857683

ABSTRACT

Non-invasive brain stimulation (NIBS) by electromagnetic fields appears to benefit human neurological and psychiatric conditions, although the optimal stimulation parameters and underlying mechanisms remain unclear. Although, in vitro studies have begun to elucidate cellular mechanisms, stimulation is delivered by a range of coils (from commercially available human stimulation coils to laboratory-built circuits) so that the electromagnetic fields induced within the tissue to produce the reported effects are ill-defined. Here, we develop a simple in vitro stimulation device with plug-and-play features that allow delivery of a range of stimulation parameters. We chose to test low intensity repetitive magnetic stimulation (LI-rMS) delivered at three frequencies to hindbrain explant cultures containing the olivocerebellar pathway. We used computational modeling to define the parameters of a stimulation circuit and coil that deliver a unidirectional homogeneous magnetic field of known intensity and direction, and therefore a predictable electric field, to the target. We built the coil to be compatible with culture requirements: stimulation within an incubator; a flat surface allowing consistent position and magnetic field direction; location outside the culture plate to maintain sterility and no heating or vibration. Measurements at the explant confirmed the induced magnetic field was homogenous and matched the simulation results. To validate our system we investigated biological effects following LI-rMS at 1 Hz, 10 Hz and biomimetic high frequency, which we have previously shown induces neural circuit reorganization. We found that gene expression was modified by LI-rMS in a frequency-related manner. Four hours after a single 10-min stimulation session, the number of c-fos positive cells increased, indicating that our stimulation activated the tissue. Also, after 14 days of LI-rMS, the expression of genes normally present in the tissue was differentially modified according to the stimulation delivered. Thus we describe a simple magnetic stimulation device that delivers defined stimulation parameters to different neural systems in vitro. Such devices are essential to further understanding of the fundamental effects of magnetic stimulation on biological tissue and optimize therapeutic application of human NIBS.


Subject(s)
Electromagnetic Fields , Equipment Design , Physical Stimulation/methods , Rhombencephalon/physiology , Transcranial Magnetic Stimulation/methods , Animals , In Vitro Techniques , Physical Stimulation/instrumentation , Transcranial Magnetic Stimulation/instrumentation
2.
Brain Stimul ; 8(1): 114-23, 2015.
Article in English | MEDLINE | ID: mdl-25444593

ABSTRACT

BACKGROUND: Repetitive transcranial magnetic stimulation is increasingly used as a treatment for neurological dysfunction. Therapeutic effects have been reported for low intensity rTMS (LI-rTMS) although these remain poorly understood. OBJECTIVE: Our study describes for the first time a systematic comparison of the cellular and molecular changes in neurons in vitro induced by low intensity magnetic stimulation at different frequencies. METHODS: We applied 5 different low intensity repetitive magnetic stimulation (LI-rMS) protocols to neuron-enriched primary cortical cultures for 4 days and assessed survival, and morphological and biochemical change. RESULTS: We show pattern-specific effects of LI-rMS: simple frequency pulse trains (10 Hz and 100 Hz) impaired cell survival, while more complex stimulation patterns (theta-burst and a biomimetic frequency) did not. Moreover, only 1 Hz stimulation modified neuronal morphology, inhibiting neurite outgrowth. To understand mechanisms underlying these differential effects, we measured intracellular calcium concentration during LI-rMS and subsequent changes in gene expression. All LI-rMS frequencies increased intracellular calcium, but rather than influx from the extracellular milieu typical of depolarization, all frequencies induced calcium release from neuronal intracellular stores. Furthermore, we observed pattern-specific changes in expression of genes related to apoptosis and neurite outgrowth, consistent with our morphological data on cell survival and neurite branching. CONCLUSIONS: Thus, in addition to the known effects on cortical excitability and synaptic plasticity, our data demonstrate that LI-rMS can change the survival and structural complexity of neurons. These findings provide a cellular and molecular framework for understanding what low intensity magnetic stimulation may contribute to human rTMS outcomes.


Subject(s)
Cell Survival/physiology , Cerebral Cortex/physiology , Electromagnetic Fields , Neurons/physiology , Animals , Calcium/metabolism , Cerebral Cortex/metabolism , Gene Expression , Mice , Neurites/physiology , Neuronal Plasticity , Neurons/cytology , Neurons/metabolism , Primary Cell Culture , Transcranial Magnetic Stimulation
3.
PLoS One ; 7(7): e40682, 2012.
Article in English | MEDLINE | ID: mdl-22866177

ABSTRACT

BACKGROUND: Recent studies have shown that the well-known effect of multisensory stimulation on body-awareness can be extended to self-recognition. Seeing someone else's face being touched at the same time as one's own face elicits changes in the mental representation of the self-face. We sought to further elucidate the underlying mechanisms and the effects of interpersonal multisensory stimulation (IMS) on the mental representation of the self and others. METHODOLOGY/PRINCIPAL FINDINGS: Participants saw an unfamiliar face being touched synchronously or asynchronously with their own face, as if they were looking in the mirror. Following synchronous, but not asynchronous, IMS, participants assimilated features of the other's face in the mental representation of their own face as evidenced by the change in the point of subjective equality for morphed pictures of the two faces. Interestingly, synchronous IMS resulted in a unidirectional change in the self-other distinction, affecting recognition of one's own face, but not recognition of the other's face. The participants' autonomic responses to objects approaching the other's face were higher following synchronous than asynchronous IMS, but this increase was not specific to the pattern of IMS in interaction with the viewed object. Finally, synchronous, as compared to asynchronous, IMS resulted in significant differences in participants' ratings of their experience, but unlike other bodily illusions, positive changes in subjective experience were related to the perceived physical similarity between the two faces, and not to identification. CONCLUSIONS/SIGNIFICANCE: Synchronous IMS produces quantifiable changes in the mental representations of one's face, as measured behaviorally. Changes in autonomic responses and in the subjective experience of self-identification were broadly consistent with patterns observed in other bodily illusions, but less robust. Overall, shared multisensory experiences between self and other can change the mental representation of one's identity, and the perceived similarity of others relative to one's self.


Subject(s)
Face , Self Concept , Adult , Female , Humans , Male , Pattern Recognition, Visual/physiology , Recognition, Psychology/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...