Insights Imaging ; 11(1): 56, 2020 Apr 03.
Article in English | MEDLINE | ID: mdl-32246276

ABSTRACT

AIMS: To identify image quality criteria that can be applied to assess breast implant (BI) mammograms according to radiologists and radiographers' perspectives and to explore the level of agreement about criteria priority. METHODS: A two-round Delphi method using a questionnaire was applied to identify the level of agreement between experts, asking them to rank each image criteria available for mammography according to 4 possible answers (1 = need to have, 2 = nice to have, 3 = not pertinent/appropriate, 4 = do not know). Criteria for craniocaudal (CC), mediolateral-oblique (MLO) and lateral (ML), with and without Eklund manoeuvre, were included. This process was repeated after removing the less relevant criteria. RESULTS: Between first and second rounds, different results were obtained regarding the criteria to assess CC and MLO images. Details for anatomic areas were considered the most relevant by radiographers during the first round, while general criteria were prioritised during the second round. Radiologists focused more on analysis of the spread of the breast tissue, if the breast was aligned with detector's centre and level of contrast. The analysis of implant flow, the BI anterior edge and the maximum retropulsion of BI when Eklund manoeuvre is performed were the specific aspects of BI imaging considered as relevant for assessment. CONCLUSIONS: The importance of each criterion used to assess BI mammograms was not the same between radiographers and radiologists, suggesting the two groups of experts are looking for different requirements from the image. Further education and training is necessary to align strategies for assessing BI mammograms, and some criteria need to be adapted to reduce subjectivity.

2.
Insights Imaging ; 11(1): 3, 2020 Jan 03.
Article in English | MEDLINE | ID: mdl-31900684

ABSTRACT

PURPOSE: To characterise the mammography technique used in breast cancer screening programmes for breast implants (BI) and to identify if the image quality (IQ) criteria available in literature are applicable to BI imaging. METHODS: The study was conducted in two phases: literature review to find IQ criteria used in mammography combining keywords in several sources; and assessment of 1207 BI mammograms using the criteria that was identified previously to see if they were achieved or not. An observation grid was used to collect information about positioning, beam energy, compression force, and exposure mode. Descriptive statistics and Student's t test and χ2 test were performed according to the nature of the variables. RESULTS: Forty-seven out of 2188 documents were included in the analysis, with 13 items identified to assess the quality of positioning, 4 for sharpness, 3 for artefacts, and 2 for exposure parameters. After applying the criteria to BI mammograms, retroglandular fat was not included in 37.3% of the images. The "Pectoral-Nipple-Line" criterion was achieved in 35% of MLO/ML images. The placement of the implant (subpectoral/subglandular) or performing the Eklund had significant influence on the visible anatomy (p = < 0.005), alongside whether the breast was aligned to the detector's centre. CONCLUSIONS: Some of the criteria used to assess standard mammograms were not applicable to BI due to implant overlap. The alignment of the image with the detector's centre seems to have an impact on the amount of visible tissue. Further studies are necessary to define the appropriate protocol, technique, and suitable quality criteria to assess BI mammograms.

3.
Rev Med Suisse ; 14(631): 2269, 2018 Dec 12.
Article in French | MEDLINE | ID: mdl-30550024
SELECTION OF CITATIONS
SEARCH DETAIL
...